Automated coulometric KF titrations

Automated coulometric KF titrations
Part Number: MATi 04

MATi 4 is a fully automated system for coulometric KF titrations with high sample throughput. Up to 160 samples in 6 mL vials can be placed on the sample rack of the Sample Processor. The sample is pipetted into an external coulometric cell and then titrated there. The system is controlled with the tiamo titration software.

  • Documentos
  • Peças
  • Water determination according to Karl Fischer with MATi 4 – Complete system for fully automated, coulometric Karl Fischer titration (english)
    • Wassergehaltsbestimmung nach Karl Fischer mit MATi 4 – Komplettsystem für die vollautomatische, coulometrische Karl-Fischer-Titration (deutsch)

Faça o download do escopo completo de entrega e acessórios opcionais

  • 786 Swing Head
    2.786.0040
    786 Swing Head
    Additional equipment for Robotic Sample Processors XL without titration or transfer heads.

    1 piece(s)

  • 800 Dosino
    2.800.0010
    800 Dosino

    Drive with write/read hardware for intelligent Dosing Units. With fixed cable (length 150 cm).

    1 piece(s)

  • 
    801 Stirrer
    2.801.0010
    801 Stirrer

    Magnetic stirrer without stand for supplementing the Titrino plus, Dosimat plus, Titrandos, Sample Processors, 805 Dosimats and 780/781 pH Meters. With permanently attached cable for MSB (Metrohm Serial Bus).


    1 piece(s)

  • 815 Robotic USB Sample Processor XL (1T/0P)
    2.815.0030
    815 Robotic USB Sample Processor XL (1T/0P)

    Robotic USB Sample Processor XL with one workstation for the automatic processing of routine samples in series with large quantities and for complex sample preparation or parallel runs. Up to two pumps (membrane or peristaltic) and three dosing devices for Liquid Handling tasks can be connected.

    Because of the multitude of application variants, rack, stirrer, titration head, robotic arm, Swing Head and sample vessels must be tailored to the application and ordered separately.
     

    1 piece(s)

  • 851 Titrando with generator electrode without diaphragm
    2.851.0110
    851 Titrando with generator electrode without diaphragm

    Coulometer including generator electrode without diaphragm.

    Coulometry is the ideal method for water determination in liquids, solids and gases when it comes to water determination in the trace range (10 µg to 10 mg absolute water). In addition, coulometry is an absolute method and thus no titer determination is necessary.

    Coulometric titrations are carried out easily and quickly with the 851 Titrando.

    Recommended measuring range: 10 µg - 200 mg absolute water

    1 piece(s)

  • Generator electrode with diaphragm
    6.0344.100
    Generator electrode with diaphragm

    Generator electrode with diaphragm for coulometric Karl Fischer titrations, SGJ 29/22.
    This generator electrode is well suited for:
     

    • samples with very low absolute water contents < 50 ppm
    • coulometric water content determination in oil samples
    • applications where ketone reagents are used
    • applications where low-conducting reagents are used (addition of chloroform, xylene >10%)

    1 piece(s)

  • Aluminum septum caps
    6.1448.050
    Aluminum septum caps
    Including Al sealing.

    1 piece(s)

  • 
    Aspiration tip / M6 thread
    6.1543.070
    Aspiration tip / M6 thread
    For the 661 Pump Unit

    1 piece(s)

  • Transfer Tubing with holder 2 x M6 / 10 mL to Sample Processors
    6.1562.130
    Transfer Tubing with holder 2 x M6 / 10 mL to Sample Processors

    Transfer tubing for dilution and preconcentration using a Dosino and Sample Processor.

    1 piece(s)

  • FEP tubing / M6 / 40 cm
    6.1805.100
    FEP tubing / M6 / 40 cm
    With light and kink protection

    1 piece(s)

  • Sample rack 160 x 6 mL
    6.2041.710
    Sample rack 160 x 6 mL
    Sample rack 160 x 6 mL vials

    1 piece(s)

  • Cable USB A – mini-DIN 8-pin
    6.2151.000
    Cable USB A – mini-DIN 8-pin
    Controller cable

    1 piece(s)

  • Sample glass, 6 mL, 1,000 pieces
    6.2419.000
    Sample glass, 6 mL, 1,000 pieces

    Sample glass, 6 mL, suitable for 61448050 septum, 1,000 pieces

    1 piece(s)

  • Crimping tongs
    6.2621.110
    Crimping tongs
    Crimping tongs for sealing 6 mL sample vials (6.2419.000, 6.2419.007).

    1 piece(s)

  • Dosing Unit 10 mL
    6.3032.210
    Dosing Unit 10 mL
    Dosing unit with integrated data chip with 10 mL glass cylinder and light protection, mountable on reagent bottle with ISO/DIN GL45 thread. FEP tubing connection, anti-diffusion buret tip.

    1 piece(s)

  • Transfer equipment, 0.5 - 2 mL, for 789/815
    6.5619.000
    Transfer equipment, 0.5 - 2 mL, for 789/815
    Complete equipment for the transfer of solutions from 0.5 to 2.0 mL on the Robotic Sample Processor.

    1 piece(s)

  • Tiamo 2.5 Light CD: 1 license
    6.6056.251
    Tiamo 2.5 Light CD: 1 license

    tiamo™ 2.5 Light computer program for controlling a titration system.

    • Up to two Metrohm instruments (Titrino, Titrando, etc.) can be connected; balances and other generic (i.e. non-Metrohm) instruments can be included without limitation
    • Graphical method editor with numerous templates
    • Layout manager for individual monitor interface
    • Professional database with reevaluation
    • High-performance report generator
    • Data export as PDF file, CSV, SLK
    • No parallel titration
    • No data export in XML format for LIMS
    • Dialog languages: German, English, French, Italian, Spanish, Czech, Portuguese, Polish, Russian, Slovakian, Japanese, Chinese, Traditional Chinese

     

    1 piece(s)