"ProfIC 9 – Anion" – Professional IC System for trace analysis with Inline Calibration, Sample Preconcentration and Matrix Elimination

"ProfIC 9 – Anion" – Professional IC System for trace analysis with Inline Calibration, Sample Preconcentration and Matrix Elimination
Part Number: ProfIC 9 - Anion

The Professional IC system with conductivity detection enables ultratrace analysis of anions down to the lowest ppt range (ng/L) in complex matrices. The "ProfIC 9" with Metrohm Inline Sample Preconcentration, Inline Calibration and Inline Matrix Elimination enables chromatography without limitation by the matrix and guarantees a long lifetime for the analytic separation column.
 

Schematic diagram
 

  • Especificações Técnicas
  • Peças
  • Opções

Dados técnicos

Parts

1 x 2.800.0010 800 Dosino
1 x 2.850.2150 850 Professional IC
1 x 2.850.9010 850 Conductivity Detector
1 x 2.858.0010 858 Professional Sample Processor
1 x 6.1014.200 Metrosep I Trap 1 column
1 x 6.1825.270 PEEK transfer tubing 10 mL
1 x 6.2841.100 rinsing station for IC Sample Processor
1 x 6.3032.210 dosing unit 10 mL
1 x 6.5330.040 IC equipment for Liquid Handling

 

IC separation column, preconcentration column, sample rack, sample vessels as well as MagIC Net have to be ordered separately and in accordance with the particular application.

Faça o download do escopo completo de entrega e acessórios opcionais

  • 800 Dosino
    2.800.0010
    800 Dosino

    Drive with write/read hardware for intelligent Dosing Units. With fixed cable (length 150 cm).

    1 piece(s)

  • 
    IC Conductivity Detector
    2.850.9010
    IC Conductivity Detector

    Compact and intelligent high performance conductivity detector for intelligent IC instruments. Outstanding temperature stability, the complete signal processing within the protected detector block and the latest generation of DSP – Digital Signal Processing – guarantee the highest precision of the measurement. No change of measuring ranges (not even automatic ones) is required, due to the dynamic working range.


    1 piece(s)

  • 
    858 Professional Sample Processor
    2.858.0010
    858 Professional Sample Processor

    The 858 Professional Sample Processor processes samples from 500 µL to 500 mL. The sample transfer takes place either by means of a peristaltic pump on the 850 Professional IC system or with an 800 Dosino.


    1 piece(s)

  • Metrosep I Trap 1 - 100/4.0
    6.1014.200
    Metrosep I Trap 1 - 100/4.0


    The Metrosep I Trap 1 - 100/4.0 column is used to eliminate ionic, i.e. cationic and anionic, contaminants from aqueous solutions. Its use is especially recommended for the purification of the transfer water in combination with "MISP" or "Metrohm Inline Sample Preparation." Using the Metrosep I Trap 1 - 100/4.0 column can significantly reduce the influence of the transfer water on the system blank.


    1 piece(s)

  • Transfer tubing 10 mL PEEK 1/8 in.
    6.1825.270
    Transfer tubing 10 mL PEEK 1/8 in.

    1 piece(s)

  • Dosing Unit 10 mL
    6.3032.210
    Dosing Unit 10 mL
    Dosing unit with integrated data chip with 10 mL glass cylinder and light protection, mountable on reagent bottle with ISO/DIN GL45 thread. FEP tubing connection, anti-diffusion buret tip.

    1 piece(s)

  • IC equipment for Liquid Handling with the Dosino
    6.5330.040
    IC equipment for Liquid Handling with the Dosino

    Accessories set for mounting a Dosino on intelligent IC instruments for Liquid Handling.


    1 piece(s)

Faça o download do escopo completo de entrega e acessórios opcionais

  • Metrosep A SUPP 5 Guard/4.0
    6.1006.500
    Metrosep A SUPP 5 Guard/4.0

    The Metrosep A Supp 5 Guard/4.0 reliably protects the Metrosep A Supp 5 and 7 IC anion columns against contamination from the sample or the eluent.

    It contains the same separation material as the Metrosep A Supp 5, is also made of PEEK, and is screwed directly onto the respective separation column with nearly no dead volume ("On Column Guard System"). The guard column prolongs the service life of the analytical column, with practically no influence on its chromatographic separating efficiency. The economical price and simple handling make using the A Supp 5 Guard/4.0 highly recommended.

  • Metrosep A Supp 5 - 250/4.0
    6.1006.530
    Metrosep A Supp 5 - 250/4.0

    The high-performance separation column from Metrohm with an extremely high number of plates for the most demanding separation tasks. Even complex separation problems can be solved easily and reproducibly with the Metrosep A Supp 5 - 250/4.0. The high capacity of the column allows, for example, the detection of 1 µg/L bromate along with 150 mg/L chloride without sample preparation. The range of applications possible with this column far exceeds the detection of standard anions. The Metrosep A Supp 5 - 250/4.0 is the column of choice when it comes to reliable monitoring of the high purity standards in the semiconductor industry or of the boiler feed water of power plants.

  • Bottle / 300 mL
    6.1608.080
    Bottle / 300 mL

    Rinsing vessel for IC Sample Processors.

  • Sample rack 16 x 120 mL
    6.2041.390
    Sample rack 16 x 120 mL
    Sample rack for 16 x 120 mL samples, one-row
  • Al foil
    6.2820.000
    Al foil
    1000 circular sheets of 80 mm diameter. Thickness: 0.010 mm. Used together with 6.2037.030 Foil holder for 6.1432.210 Sample beaker. For 674 KF Sample Changer
  • IQ/OQ Kit for IC
    6.5333.000
    IQ/OQ Kit for IC
    The IQ/OQ Kit contains all parts and standard solutions required for IQ/OQ in ion chromatography.
  • Connecting set to Dosing Unit: port 4
    6.5620.000
    Connecting set to Dosing Unit: port 4
    For connecting a tubing to port 4 of the Dosing Unit (Luer to M6), incl. fixation