OMNIS Professional Titrator without stirrer

OMNIS Professional Titrator without stirrer
Artikkelnummer: 2.1001.0310

Innovative, modular potentiometric OMNIS Titrator for endpoint titration and equivalence point titration (monotonic/dynamic) with one OMNIS Sample Robot. Thanks to 3S Liquid Adapter technology, handling chemicals is more secure than ever before. The titrator can be freely configured with measuring modules and cylinder units and can have a stirrer added as needed. Including "Professional" function license for parallel titration with additional titration or dosing modules.
 

  • Control via PC or local network
  • Connection option for up to four additional titration or dosing modules for additional applications or auxiliary solutions
  • Can be supplemented with magnetic stirrer and/or rod stirrer
  • Various cylinder sizes available: 5, 10, 20 or 50 mL
  • Liquid Adapter with 3S technology: Secure handling of chemicals, automatic transfer of the original reagent data from the manufacturer

    Measuring modes and software options:
  • Endpoint titration: "Basic" function license
  • Endpoint and equivalence point titration (monotonic/dynamic): "Advanced" function license
  • Endpoint and equivalence point titration (monotonic/dynamic) with parallel titration: "Professional" function license
  • Dokumenter
  • Delebetegnelse
  • Tilleggsutstyr

Last ned en komplett deleliste i PDF:

  • OMNIS Liquid Adapter
    6.01600.010
    OMNIS Liquid Adapter

    Adapter for connecting reagent bottles with 3S technology to an OMNIS Titrator, Titration Module or Dosing Module.

    1 piece(s)

  • Bottle cap, multi-use
    6.01601.000
    Bottle cap, multi-use

    Reusable bottle cap with 3S technology for connecting reagent bottles to an OMNIS Titrator, Titration Module or Dosing Module.

    1 piece(s)

  • Bottle holder
    6.02004.010
    Bottle holder

    Bottle holder for OMNIS Titrator, Titration Module and Dosing Module.

    1 piece(s)

  • Electrode Parking Station
    6.02005.010
    Electrode Parking Station

    Electrode Parking Station for electrode storage on an OMNIS titration system.

    1 piece(s)

  • Function license Professional
    6.06001.920
    Function license Professional

    "Professional" function license for one OMNIS Titrator
     

    • Liquid Handling (LQH)
    • MEAS U/T/pH
    • Calibration (Cal)
    • Endpoint titration without conditioning (SET)
    • Monotonic equivalence point titration (MET)
    • Dynamic equivalence point titration (DET)
    • Parallel titration

    1 piece(s)

  • Extractor rod
    6.1546.030
    Extractor rod
    For PTFE piston of dosing unit

    1 piece(s)

  • Glass bottle / 1000 mL / GL 45
    6.1608.020
    Glass bottle / 1000 mL / GL 45

    Bottle for auxiliary solutions.

    1 piece(s)

Last ned en komplett deleliste i PDF:

  • dUnitrode with Pt1000
    6.00200.300
    dUnitrode with Pt1000

    Digital, combined pH electrode for OMNIS with integrated Pt1000 temperature sensor. This electrode is particularly suitable:
    - for pH measurements and titrations in difficult, viscous, or alkaline samples
    - at elevated temperatures
    - for long-term measurements
    The fixed ground-joint diaphragm is insensitive to contamination.

    Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.
    Alternatively: reference electrolyte for measurements at T>80°C: Idrolyte, storage in Idrolyte.

  • dEcotrode plus
    6.00201.300
    dEcotrode plus

    Digital, combined pH electrode for OMNIS.
    This electrode is suitable for aqueous acid/base titrations.
    The fixed ground-joint diaphragm is insensitive to contamination.
    Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.

  • dAquatrode Plus with Pt1000
    6.00202.300
    dAquatrode Plus with Pt1000

    Digital, combined pH electrode for OMNIS, with integrated Pt1000 temperature sensor, for pH measurements/titrations in ion-deficient aqueous media (e.g., drinking water, process water). This electrode shows a very short response time in these samples.
    The fixed ground-joint diaphragm is insensitive to contamination.
    When c(KCl) = 3 mol/L is used as bridge electrolyte, storage in storage solution is recommended.
    The bridge electrolyte can be easily replaced with a chloride-free electrolyte (e.g., potassium nitrate c(KNO3) = 1 mol/L (6.2310.010)). Storage in the used bridge electrolyte.

  • dSolvotrode
    6.00203.300
    dSolvotrode

    Digital, combined pH electrode for OMNIS for all non-aqueous acid/base titrations. The glass membrane is optimized for poorly conducting solutions, and thanks to the flexible ground-joint diaphragm, the electrode is well suited for contaminated samples.

    This electrode can be used with non-aqueous reference electrolytes (lithium chloride or tetraethylammonium bromide).

    Storage in the respective reference electrolyte.

  • dProfitrode
    6.00204.300
    dProfitrode

    Digital, combined pH electrode for OMNIS with double-junction construction. This electrode is suitable for pH measurements/titrations of samples:

    • that contaminate the reference system of the electrode (e.g., galvanic baths, samples containing sulfides)
    • for which potassium chloride c(KCl) = 3 mol/L cannot be used as reference electrolyte (e.g., reaction of potassium or chloride with sample)

    The electrode is equipped with a flexible ground-joint diaphragm which is insensitive to contamination and which can be exchanged when needed.
    When c(KCl) = 3 mol/L is used as as bridge electrolyte, storage in storage solution is recommended.
    The bridge electrolyte can be easily replaced with a suitable electrolyte (e.g., potassium nitrate c(KNO3) = 1 mol/L (6.2310.010)). Storage in the used bridge electrolyte.

  • dAg Titrode
    6.00400.300
    dAg Titrode

    Digital, combined silver ring electrode for OMNIS with a pH glass membrane as reference electrode.
    This maintenance-free electrode is well suited for precipitation titrations when the pH value remains constant (titrant silver nitrate) of, e.g.:
     

    • chloride, bromide, iodide
    • sulfides
    • hydrogen sulfide
    • mercaptans
    • cyanides


    This electrode is stored in deion. water.

  • dPt Titrode
    6.00401.300
    dPt Titrode

    Digital, combined platinum ring electrode for OMNIS with a pH glass membrane as reference electrode.
    This maintenance-free electrode is well suited for redox titrations when the pH value remains constant, e.g.:
     

    • iodometry
    • chromatometry
    • cerimetry
    • permanganometry


    This electrode is stored in deion. water.

  • dAg ring electrode
    6.00402.300
    dAg ring electrode

    Digital, combined silver ring electrode for OMNIS with fixed ground-joint diaphragm.
    This electrode is well suited for precipitation titrations when the pH value varies (titrant silver nitrate) of, e.g.:
     

    • chloride, bromide, iodide
    • sulfides
    • hydrogen sulfide
    • mercaptans
    • cyanides


    The fixed ground-joint diaphragm is insensitive to contamination. c(KNO3) = 1 mol/L is used as reference electrolyte and storage solution.

  • dPt ring electrode
    6.00403.300
    dPt ring electrode

    Digital, combined platinum ring electrode for OMNIS with fixed ground-joint diaphragm.
    This electrode is well suited for redox titrations when the pH value varies, e.g.:
     

    • oxygen content according to Winkler
    • determination of hydrogen peroxide with KMnO4
    • diazotization titrations


    The fixed ground-joint diaphragm is insensitive to contamination. c(KCl) = 3 mol/ L is used as reference electrolyte and storage solution.

  • Combined dCa ISE
    6.00502.300
    Combined dCa ISE

    Digital, combined calcium-selective electrode for OMNIS.
    This ISE is suitable for:
     

    • ion measurements of Ca2+ (1*10-7 to 1 mol/L) in aqueous solutions
    • complexometric (back) titrations (e.g., determination of water hardness)


    Thanks to a robust/break-proof plastic shaft made of propylene and an impact protection for the polymer membrane, this sensor is mechanically very resistant.
    The reference electrolyte used is c(KCl) = 3 mol/L.

  • OMNIS 2 mL cylinder unit without accessories
    6.01503.120
    OMNIS 2 mL cylinder unit without accessories

    Intelligent 2 mL cylinder unit for an OMNIS Titrator, Titration Module or Dosing Module. Without dosing tubing and antidiffusion tip.

  • OMNIS 5 mL cylinder unit without accessories
    6.01503.150
    OMNIS 5 mL cylinder unit without accessories

    Intelligent 5 mL cylinder unit for an OMNIS Titrator, Titration Module or Dosing Module. Without dosing tubing and antidiffusion tip.

  • OMNIS 10 mL cylinder unit without accessories
    6.01503.210
    OMNIS 10 mL cylinder unit without accessories

    Intelligent 10 mL cylinder unit for an OMNIS Titrator, Titration Module or Dosing Module. Without dosing tubing and antidiffusion tip.

  • OMNIS 20 mL cylinder unit without accessories
    6.01503.220
    OMNIS 20 mL cylinder unit without accessories

    Intelligent 20 mL cylinder unit for an OMNIS Titrator, Titration Module or Dosing Module. Without dosing tubing and antidiffusion tip.

  • OMNIS 50 mL cylinder unit without accessories
    6.01503.250
    OMNIS 50 mL cylinder unit without accessories

    Intelligent 50 mL cylinder unit for an OMNIS Titrator, Titration Module or Dosing Module. Without dosing tubing and antidiffusion tip.

  • Electrode cable plug-in head G / plug P, 0.55 m
    6.02104.000
    Electrode cable plug-in head G / plug P, 0.55 m

    Cable for connecting an analog electrode (plug-in head G) to an analog measuring module from OMNIS.

  • Electrode cable plug-in head G / plug P, 1.5 m
    6.02104.010
    Electrode cable plug-in head G / plug P, 1.5 m

    Cable for connecting an analog electrode (plug-in head G) to an analog measuring module from OMNIS.

  • Electrode cable plug-in head G (temp.) / plug P, 0.55 m
    6.02104.020
    Electrode cable plug-in head G (temp.) / plug P, 0.55 m

    Cable for connecting a temperature sensor (head G) to an analog measuring module from OMNIS.

  • Electrode cable plug-in head G (temp.) / plug P, 1.5 m
    6.02104.030
    Electrode cable plug-in head G (temp.) / plug P, 1.5 m

    Cable for connecting a temperature sensor (head G) to an analog measuring module from OMNIS.

  • Electrode cable plug-in head G (pol.) / plug P, 0.55 m
    6.02104.040
    Electrode cable plug-in head G (pol.) / plug P, 0.55 m

    Cable for connecting an analog polarizable electrode (plug-in head G) to an analog measuring module from OMNIS.

  • Electrode cable plug-in head G (pol.) / plug P, 1.5 m
    6.02104.050
    Electrode cable plug-in head G (pol.) / plug P, 1.5 m

    Cable for connecting an analog polarizable electrode (plug-in head G) to an analog measuring module from OMNIS.

  • Electrode cable plug-in head Q / plug P, 0.55 m
    6.02104.300
    Electrode cable plug-in head Q / plug P, 0.55 m

    Cable for connecting a dTrode (plug-in head Q) to the digital measuring module from OMNIS.

  • Electrode cable plug-in head Q / plug P, 1.5 m
    6.02104.310
    Electrode cable plug-in head Q / plug P, 1.5 m

    Cable for connecting a dTrode (plug-in head Q) to the digital measuring module from OMNIS.

  • Electrode cable plug-in head U / plug P, 0.55 m
    6.02104.600
    Electrode cable plug-in head U / plug P, 0.55 m

    Cable for connecting an electrode with plug-in head U to an analog measuring module from OMNIS.

  • Electrode cable plug-in head U / plug P, 1.5 m
    6.02104.610
    Electrode cable plug-in head U / plug P, 1.5 m

    Cable for connecting an electrode with plug-in head U to an analog measuring module from OMNIS.

  • Liquid Adapter extension cable, 0.55 m
    6.02106.000
    Liquid Adapter extension cable, 0.55 m

    Extension cable (0.55 m in length) for connecting an OMNIS Liquid Adapter to an OMNIS Titrator, Titration Module or Dosing Module.

  • Liquid Adapter extension cable, 2 m
    6.02106.010
    Liquid Adapter extension cable, 2 m

    Extension cable (2 m in length) for connecting an OMNIS Liquid Adapter to an OMNIS Titrator, Titration Module or Dosing Module.

  • OMNIS 2 mL cylinder unit
    6.03001.120
    OMNIS 2 mL cylinder unit

    Intelligent 2 mL cylinder unit for an OMNIS Titrator, Titration Module or Dosing Module. Includes dosing tubing and antidiffusion tip.

  • OMNIS 5 mL cylinder unit
    6.03001.150
    OMNIS 5 mL cylinder unit

    Intelligent 5 mL cylinder unit for an OMNIS Titrator, Titration Module or Dosing Module. Includes dosing tubing and antidiffusion tip.

  • OMNIS 10 mL cylinder unit
    6.03001.210
    OMNIS 10 mL cylinder unit

    Intelligent 10 mL cylinder unit for an OMNIS Titrator, Titration Module or Dosing Module. Includes dosing tubing and antidiffusion tip.

  • OMNIS 20 mL cylinder unit
    6.03001.220
    OMNIS 20 mL cylinder unit

    Intelligent 20 mL cylinder unit for an OMNIS Titrator, Titration Module or Dosing Module. Includes dosing tubing and antidiffusion tip.

  • OMNIS 50 mL cylinder unit
    6.03001.250
    OMNIS 50 mL cylinder unit

    Intelligent 50 mL cylinder unit for an OMNIS Titrator, Titration Module or Dosing Module. Includes dosing tubing and antidiffusion tip.

  • KFT equipment for OMNIS Titrator
    6.05609.000
    KFT equipment for OMNIS Titrator

    Complete accessory set for volumetric Karl Fischer titration.

  • KFT equipment for OMNIS Titrator with Polytron
    6.05609.010
    KFT equipment for OMNIS Titrator with Polytron

    Complete accessory set for volumetric Karl Fischer titration with Polytron.

  • Function license KFT with conditioning
    6.06001.160
    Function license KFT with conditioning

    Function license for volumetric Karl Fischer titration with conditioning for an OMNIS titration system.