NIRS XDS RapidLiquid Analyzer

NIRS XDS RapidLiquid Analyzer
Artikkelnummer: 2.921.1410

Rapid, precise analyses of liquids and suspensions of all types.

The NIRS XDS RapidLiquid Analyzer enables rapid, precise analyses of liquid formulations and substances. Precise measurement results at the push of a button make the NIRS XDS RapidLiquid Analyzer an equally reliable and simple solution for quality monitoring in laboratories and processes. The samples are transferred to quartz cuvettes designed for multiple use or disposable glass vials; a tempered sample compartment ensures reproducible analysis conditions and thus accurate measurement results.

 

  • Dokumenter
  • Delebetegnelse
  • Tilleggsutstyr
  • Brochure: Hydroxyl number in polyols – Rapid and simple determination with near-infrared spectroscopy (english)
  • Brochure: NIRS XDS RapidLiquid Analyzer – Rapid, precise analyses of liquids and suspensions of all types (english)
    • Prospekt: NIRS XDS RapidLiquid Analyzer – Schnelle, präzise Analysen von Flüssigkeiten und Suspensionen aller Art (deutsch)
    • Brochure: NIRS XDS RapidLiquid Analyzer – Rapid, precise analyses of liquids and suspensions of all types (日本語)
  • Brochure: RON, MON, aromatics, benzene, and olefins in gasoline – Fast and straightforward determination by near-infrared spectroscopy (english)
  • Brochure: Upgrade from System II Analyzers to Metrohm NIRSystems Analyzers (english)
  • Brochure: Cetane index and number, density, and flash point in diesel – Fast and straightforward determination by near-infrared spectroscopy (english)
  • Brochure: Cetane index, density, aromatics, saturates, and hydrogen in jet fuel – Fast and straightforward determination by near-infrared spectroscopy (english)
  • Brochure: Free fatty acids, moisture and iodine value in palm oil – Fast and straightforward determination by near-infrared spectroscopy (english)
  • Brochure: Spectroscopy solutions for pharmaceutical analysis – Faster, safer, and much more economical (english)
  • Declaration of Conformity for NIRS XDS Analyzers (english)
  • Manual for NIRS XDS RapidLiquid Analyzer (english)
    • NIRS XDS RapidLiquid Analyzer 手册 (中文)
    • Mode d’emploi NIRS XDS RapidLiquid Analyzer (français)
    • Handbuch NIRS XDS RapidLiquid Analyzer (deutsch)
    • Manual NIRS XDS RapidLiquid Analyzer (español)

Last ned en komplett deleliste i PDF:

  • NIRS XDS accessory kit
    6.7400.000
    NIRS XDS accessory kit

    Accessory kit for NIRS XDS laboratory monochromators

    1 piece(s)

Last ned en komplett deleliste i PDF:

  • Vision Air 2.0 Network Complete
    6.6072.207
    Vision Air 2.0 Network Complete

    Vision Air - Universal spectroscopy software.

    Vision Air Network is a modern and simple-to-operate software solution. The network version enables the structuring of a global server-client network with a central database.

    Overview of the advantages of Vision Air:
     

    • Individual software applications with adapted user interfaces ensure intuitive and simple operation
    • Centralized data and instrument management
    • Simple configuration and updating of several devices in just a few steps
       

    The Vision Air Network Complete version (66072207) contains all applications for quality assurance using Vis-NIR spectroscopy:
     

    • Application for a global instrument and data management
    • Application for method development
    • Application for routine analysis

     

  • Vision Air 2.0 Complete
    6.6072.208
    Vision Air 2.0 Complete

    Vision Air - Universal spectroscopy software.

    Vision Air Complete is a modern and simple-to-operate software solution for use in a regulated environment.

    Overview of the advantages of Vision Air:
     

    • Individual software applications with adapted user interfaces ensure intuitive and simple operation
    • Simple creation and maintenance of operating procedures
    • SQL database for secure and simple data management


    The Vision Air Complete version (66072208) includes all applications for quality assurance using Vis-NIR spectroscopy:
     

    • Application for instrument and data management
    • Application for method development
    • Application for routine analysis


    Additional Vision Air Complete solutions:
     

    • 66072207 (Vision Air Network Complete)
    • 66072209 (Vision Air Pharma Complete)
    • 66072210 (Vision Air Pharma Network Complete)

     

  • Vision Air 2.0 Pharma Complete
    6.6072.209
    Vision Air 2.0 Pharma Complete

    Vision Air - Universal spectroscopy software.

    Vision Air Pharma Complete is a modern and simple-to-operate software solution for use in regulated environments.

    Overview of the advantages of Vision Air:
     

    • Individual software applications with adapted user interfaces ensure intuitive and simple operation
    • Simple creation and maintenance of operating procedures
    • SQL database for safe and simple data management
    • In compliance with all requirements pursuant to Title 21 CFR Part 11


    The Vision Air Pharma Complete version (66072209) contains all applications for quality assurance using Vis-NIR spectroscopy:
     

    • Application for instrument and data management
    • Application for method development
    • Application for routine analysis

     

  • Vision Air 2.0 Pharma Network Complete
    6.6072.210
    Vision Air 2.0 Pharma Network Complete

    Vision Air - Universal spectroscopy software.

    Vision Air Pharma Network Complete is a modern and simple-to-operate software solution. The network version enables the setup of a global server-client network with a central database.

    Overview of the advantages of Vision Air:
     

    • Individual software applications with adapted user interfaces ensure intuitive and simple operation
    • Centralized data and instrument management
    • Simple configuration and updating of several instruments in just a few steps
    • In compliance with all requirements pursuant to Title 21 CFR Part 11


    The Vision Air Pharma Network Complete version (66072210) contains all applications for quality assurance using Vis-NIR spectroscopy:
     

    • Application for a global instrument and data management
    • Application for method development
    • Application for routine analysis
       

     

  • Pre-calibration for the analysis of polyols
    6.6072.301
    Pre-calibration for the analysis of polyols

    Pre-calibration for determination of the hydroxyl number in polyols by means of NIR spectroscopy.

  • Pre-calibration for palm oil analysis
    6.6072.302
    Pre-calibration for palm oil analysis

    Determination of iodine number, water and fatty acid content in palm oil.

  • Pre-calibration for palm kernel oil analysis
    6.6072.303
    Pre-calibration for palm kernel oil analysis

    Determination of iodine number, water and fatty acid content in palm kernel oil.
     

  • Pre-calibration for RBD palm oil analysis
    6.6072.304
    Pre-calibration for RBD palm oil analysis

    Determination of iodine number, water and fatty acid content in RBD palm oil

  • Pre-calibration for diesel analysis
    6.6072.305
    Pre-calibration for diesel analysis

    Determination of cetane index und cetane number, as well as density, cold filter plugging point, flash point and sulfur in diesel fuel.

  • Pre-calibration for gasoline analysis
    6.6072.306
    Pre-calibration for gasoline analysis

    Determination of octane number, LCI, benzene, aromatic compounds, olefins, oxygen and density in gasoline.

  • Pre-calibration for kerosine analysis
    6.6072.307
    Pre-calibration for kerosine analysis

    Determination of cetane index, aromatic compounds, density, flash point, hydrogen, viscosity and other parameters in kerosine.

  • NIRS XDS quartz cuvette, screw top, 20 mm pathlength
    6.7401.040
    NIRS XDS quartz cuvette, screw top, 20 mm pathlength

    Quartz cuvette, screw top, with 20 mm pathlength for the recording of a spectrum of volatile liquids in transmission using an NIRS XDS RLA Analyzer.

  • NIRS XDS quartz cuvette with open top, 0.5 mm pathlength
    6.7401.110
    NIRS XDS quartz cuvette with open top, 0.5 mm pathlength

    Open quartz cuvette with 0.5 mm pathlength for the recording of a spectrum of liquids in transmission using an NIRS XDS RLA Analyzer.

  • NIRS 12.5 mm quartz cuvette 1 mm
    6.7401.200
    NIRS 12.5 mm quartz cuvette 1 mm

    Quartz glass cuvette with a window made of quartz glass of maximum purity and homogeneity. The cuvettes have a transmission of more than 80% in the wavelength range of 200 nm - 2,500 nm.

    A number of different pathlengths are available:

    • 1 mm pathlength and a volume = 350 μL (order number: 67401200)
    • 2 mm pathlength and a volume = 700 μL (order number: 67401210)
    • 5 mm pathlength and a volume = 1,750 μL (order number: 67401220)
    • 10 mm pathlength and a volume = 3,500 μL (order number: 67401230)

    The NIRS Spacer for 12.5 mm cuvette set (order number: 67403180) ensures spacers for an optimum position of the cuvette in the sample holder.

     

  • NIRS 12.5 mm quartz cuvette 2 mm
    6.7401.210
    NIRS 12.5 mm quartz cuvette 2 mm

    Quartz glass cuvette with a window made of quartz glass of maximum purity and homogeneity. The cuvettes have a transmission of more than 80% in the wavelength range of 200 nm - 2,500 nm.

    A number of different pathlengths are available:

    • 1 mm pathlength and a volume = 350 μL (order number: 67401200)
    • 2 mm pathlength and a volume = 700 μL (order number: 67401210)
    • 5 mm pathlength and a volume = 1,750 μL (order number: 67401220)
    • 10 mm pathlength and a volume = 3,500 μL (order number: 67401230)

    Appropriate spacers for an optimum position of the cuvette in the sample holder can be found in the NIRS Spacer for 12.5 mm cuvette set (order number: 67403180).

  • NIRS 12.5 mm quartz cuvette 5 mm
    6.7401.220
    NIRS 12.5 mm quartz cuvette 5 mm

    Quartz glass cuvette with a window made of quartz glass of maximum purity and homogeneity. The cuvettes have a transmission of more than 80% in the wavelength range of 200 nm - 2,500 nm.

    A number of different pathlengths are available:

    • 1 mm pathlength and a volume = 350 μL (order number: 67401200)
    • 2 mm pathlength and a volume = 700 μL (order number: 67401210)
    • 5 mm pathlength and a volume = 1,750 μL (order number: 67401220)
    • 10 mm pathlength and a volume = 3,500 μL (order number: 67401230)

    Appropriate spacers for an optimum position of the cuvette in the sample holder can be found in the NIRS Spacer for 12.5 mm cuvette set (order number: 67403180).

     

  • NIRS 12.5 mm quartz cuvette 10 mm 
    6.7401.230
    NIRS 12.5 mm quartz cuvette 10 mm 

    Quartz glass cuvette with a window made of quartz glass of maximum purity and homogeneity. The cuvettes have a transmission of more than 80% in the wavelength range of 200 nm - 2,500 nm.

    A number of different pathlengths are available:

    • 1 mm pathlength and a volume = 350 μL (order number: 67401200)
    • 2 mm pathlength and a volume = 700 μL (order number: 67401210)
    • 5 mm pathlength and a volume = 1,750 μL (order number: 67401220)
    • 10 mm pathlength and a volume = 3,500 μL (order number: 67401230)

    Appropriate spacers for an optimum position of the cuvette in the sample holder can be found in the NIRS Spacer for 12.5 mm cuvette set (order number: 67403180).

     

  • NIRS 12.5 mm quartz cuvette flow 0.5 mm
    6.7401.300
    NIRS 12.5 mm quartz cuvette flow 0.5 mm

    The flow quartz cuvettes enable continuous monitoring, e.g., of tablet disintegration processes and reaction kinetics. The high pressure resistance and a special bubble capturing system make all of the measurements particularly convenient.

    Windows made of quartz glass of maximum purity and homogeneity ensure a transmission of more than 80% in the wavelength range of 200 nm - 2,500 nm.

     

     

     

  • NIRS 12.5 mm quartz cuvette flow 1 mm
    6.7401.310
    NIRS 12.5 mm quartz cuvette flow 1 mm

    The flow quartz cuvettes enable continuous monitoring, e.g., of tablet disintegration processes and reaction kinetics. The high pressure resistance and a special bubble capturing system make all of the measurements particularly convenient.

    Windows made of quartz glass of maximum purity and homogeneity ensure a transmission of more than 80% in the wavelength range of 200 nm - 2,500 nm.

    A number of different pathlengths are available:

    0.5 mm pathlength and a volume = 175 μL (order number: 67401300)
    1 mm pathlength and a volume = 350 μL (order number: 67401310)
    2 mm pathlength and a volume = 700 μL (order number: 67401320)
    5 mm pathlength and a volume = 1,750 μL (order number: 67401330)
    10 mm pathlength and a volume = 3,500 μL (order number: 67401340)

    The NIRS Spacer for 12.5 mm cuvette set ensures spacers for an optimum position of the cuvette in the sample holder (order number: 67403180).

     

     

     

  • NIRS 12.5 mm quartz cuvette flow 2 mm
    6.7401.320
    NIRS 12.5 mm quartz cuvette flow 2 mm

    The flow quartz cuvettes enable continuous monitoring, e.g., of tablet disintegration processes and reaction kinetics. The high pressure resistance and a special bubble capturing system make all of the measurements particularly convenient.

    Windows made of quartz glass of maximum purity and homogeneity ensure a transmission of more than 80% in the wavelength range of 200 nm - 2,500 nm.

  • NIRS 12.5 mm quartz cuvette flow 5 mm
    6.7401.330
    NIRS 12.5 mm quartz cuvette flow 5 mm

    The flow quartz cuvettes enable continuous monitoring, e.g., of tablet disintegration processes and reaction kinetics. The high pressure resistance and a special bubble capturing system make all of the measurements particularly convenient.

    Windows made of quartz glass of maximum purity and homogeneity ensure a transmission of more than 80% in the wavelength range of 200 nm - 2,500 nm.

  • NIRS 12.5 mm quartz cuvette flow 10 mm
    6.7401.340
    NIRS 12.5 mm quartz cuvette flow 10 mm

    The flow quartz cuvettes enable continuous monitoring, e.g., of tablet disintegration processes and reaction kinetics. The high pressure resistance and a special bubble capturing system make all of the measurements particularly convenient.

    Windows made of quartz glass of maximum purity and homogeneity ensure a transmission of more than 80% in the wavelength range of 200 nm - 2,500 nm.

  • Disposable vials, 8 mm diameter, transmission
    6.7402.000
    Disposable vials, 8 mm diameter, transmission

    250 lockable disposable glass vials (borosilicate) with a diameter of 8 mm for analyses of liquid samples in transmission mode. Suitable for the following Analyzers:

    NIRS XDS RapidLiquid Analyzer
    NIRS XDS VialHeater + NIRS XDS Transmission OptiProbe Analyzer

     

  • Disposable vials, 4 mm diameter, transmission
    6.7402.010
    Disposable vials, 4 mm diameter, transmission

    200 disposable glass vials (borosilicate) with a diameter of 4 mm for analyses of liquid samples in transmission mode. Suitable for the following Analyzers:
     

    • NIRS XDS RapidLiquid Analyzer
    • NIRS XDS VialHeater + NIRS XDS Transmission OptiProbe Analyzer

     

  • Disposable vials, 2 mm diameter, transmission
    6.7402.070
    Disposable vials, 2 mm diameter, transmission

    200 lockable disposable glass vials (borosilicate) with a diameter of 2 mm for analyses of liquid samples in transmission mode. Suitable for the following Analyzers:
     

    • NIRS XDS RapidLiquid Analyzer
    • NIRS XDS VialHeater + NIRS XDS Transmission OptiProbe Analyzer

     

  • Disposable vials, 10 mm diameter, transmission
    6.7402.100
    Disposable vials, 10 mm diameter, transmission

    195 lockable disposable glass vials (borosilicate) with a diameter of 10 mm for analyses of liquids in transmission mode. Suitable for the following Analyzers:

    • NIRS XDS RapidLiquid Analyzer
    • NIRS XDS VialHeater + NIRS XDS Transmission OptiProbe Analyzer

     

  • NIRS XDS spacer for disposable 8 mm vials (6.7402.000)
    6.7403.000
    NIRS XDS spacer for disposable 8 mm vials (6.7402.000)

    Spacer for disposable glass vials with 8 mm diameter.

  • NIRS XDS spacer for disposable 4 mm vials (6.7402.010)
    6.7403.010
    NIRS XDS spacer for disposable 4 mm vials (6.7402.010)

    Spacer for disposable glass vials with 4 mm diameter

  • XDS spacer for disposable 2 mm vials (6.7402.070)
    6.7403.020
    XDS spacer for disposable 2 mm vials (6.7402.070)

    Spacer for the disposable glass vials with 2 mm diameter.

  • XDS spacer for disposable 10 mm vials (6.7402.100)
    6.7403.030
    XDS spacer for disposable 10 mm vials (6.7402.100)

    Spacer for the disposable glass vials with 10 mm diameter.

  • NIRS XDS spacer for 0.5 mm cuvettes (6.7401.110)
    6.7403.110
    NIRS XDS spacer for 0.5 mm cuvettes (6.7401.110)

    Spacer for fixing open quartz cuvettes with 0.5 mm total pathlength in an NIRS XDS RLA Analyzer.

  • NIRS Spacer for 12.5 mm cuvettes
    6.7403.180
    NIRS Spacer for 12.5 mm cuvettes

    The NIRS Spacer for 12.5 mm cuvette set ensures spacers for an optimum position of the cuvette in the sample holder.

  • NIRS XDS lab spare lamp
    6.7430.000
    NIRS XDS lab spare lamp

    Spare lamp with 12 V and 50 W for the monochromator of the NIRS XDS laboratory instruments

  • NIRS XDS lab spare parts kit
    6.7430.010
    NIRS XDS lab spare parts kit

    NIRS XDS lab spare parts kit

  • NIRS XDS Monochromator fan filter, 10 pcs.
    6.7430.020
    NIRS XDS Monochromator fan filter, 10 pcs.

    Ten NIRS XDS fan filters for the monochromator

  • Micro Fiber Cleaning Cloth
    6.7430.060
    Micro Fiber Cleaning Cloth

    Cleaning cloth for monitors and optics.

  • NIRS transmission wavelength calibration standard
    6.7450.040
    NIRS transmission wavelength calibration standard

    Transmission wavelength calibration standard for NIRS XDS RLA Analyzer and NIRS XDS Transmission OptiProbe Analyzer

  • Certified wavelength and transmission standards (6-pc. set).
    6.7450.130
    Certified wavelength and transmission standards (6-pc. set).

    Certified wavelength and transmission standards (0.25 AU, 0.5 AU, 1 AU, 1.5 AU and 2.0 AU) for NIRS XDS RapidLiquid Analyzer and NIRS XDS Transmission OptiProbe Analyzer in regulated environments.