Solitrode electrode plug-in head U with cable set

Solitrode electrode plug-in head U with cable set
Artikkelnummer: 6.5106.000

Set comprises a Solitrode with Pt1000 temperature sensor (6.0228.600) and cable (length 1.2 m).

This electrode is suitable for routine pH measurements in solutions that do not contain precipitates, proteins, or sulfides. This electrode is mechanically resistant thanks to the robust/unbreakable plastic shaft made of polypropylene and impact protection for the glass membrane.

  • Delebetegnelse
  • Tilleggsutstyr

Last ned en komplett deleliste i PDF:

  • Solitrode with Pt1000
    6.0228.600
    Solitrode with Pt1000

    Combined pH electrode with integrated Pt1000 temperature sensor.
    This electrode is suitable for routine pH measurements in solutions that do not contain precipitates, proteins, or sulfides. This electrode is mechanically resistant thanks to the robust/unbreakable plastic shaft made of polypropylene and impact protection for the glass membrane.
    Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.

    1 piece(s)

  • Electrode cable for plug in head U/plug F, 2x2 mm B, 1m
    6.2104.600
    Electrode cable for plug in head U/plug F, 2x2 mm B, 1m
    For connecting electrodes with Metrohm plug-in head U to Metrohm instruments (socket F).

    1 piece(s)

Last ned en komplett deleliste i PDF:

  • Electrolyte  3 mol/L KCl (250 mL)
    6.2308.020
    Electrolyte 3 mol/L KCl (250 mL)
    Electrolyte solution c(KCl) = 3 mol/L, (for Ag/AgCl reference systems)
  • Storage solution
    6.2323.000
    Storage solution
    Storage solution for all combined pH glass electrodes with reference electrolyte c(KCl) = 3 mol/L
  • pHit kit
    6.2325.000
    pHit kit

    Maintenance kit for pH electrodes

    The kit contains:

    • 50 mL cleaning solution
    • 50 mL 3M KCl solution
    • 50 mL storage solution
    • 2 Storage vessels
    • Instructions for use
  • Cleaning solution 3 x 50 mL
    6.2325.100
    Cleaning solution 3 x 50 mL

    Reliable measuring results over long periods of time can be guaranteed only if the pH glass membrane and the diaphragm receive preventive and regular care. Cleaning by etching with toxic chemicals or applying mechanical treatment to the diaphragm is not only complicated and expensive, it also accelerates the ageing of the pH glass electrode.
    The cleaning solution was developed for easy and gentle cleaning of pH glass electrodes. Regular use can considerably prolong their service life.

    This cleaning solution is also part of the pHit kit.