The NIRS XDS Process Analyzer – SingleFiber provides the next generation of process analyzers for real-time analysis in the pharmaceutical and chemical industries. Non-destructive, accurate measurements of clear liquids are performed directly in the process line or in a reaction vessel. All 4 channels can be configured independently from each other in the software. Single fiber optics allows the 4 measuring points to be up to 100 meter away from the XDS NIR process analyzer.

  • Spesifikasjoner
  • Tilleggsutstyr

Technical specifications
Wavelength range: 800 - 2,200 nm
Detector: Extended InGaAs (Indium Gallium Arsenide)
Data Increment: 0.5 nm
Average time per result: 3 - 30 seconds

General
Lifetime of the light source: = 8000 h
Power supply: 100 - 240 VAC, 50 - 60 Hz, 1 A,
Power consumption: 100 W typical, max. 300 W
Software package: Vision for instrument operation and method development
Standard Operating temperature: 0 - 35 °C (32 - 95 °F)
Humidity: 10 - 90% relative
Weight: 42.2 kg (93 lbs)
Dimensions (W x H x D): 407 x 610 x 362 mm (16 x 24 x 14.25 inches)
Housing: basic device IP65/Nema 4X, stainless steel
Various enclosure options for hazardous areas or environmental conditions outside the above mentioned conditions available.

Fiber Optics and Probes

  • Single Fiber Optic Cable with SMA connectors at the analyzer and probe (requires probe or flow-through cell for use)
  • Stainless Steel or Hastalloy Probes (other materials available as well)
    Micro Transmission Probe Pair
    Single-sided Transmission Probe
    Purge and 45 degree angle probe
    Transmission flow-through cell


Process Communication Options

  • OPC
  • Digital protocols
    MODBUS, PROFIBUS, etc.
  • VISION I/O Modules
    Available with 8, 16, or 24 Analog Channels, 24 Digital Channels

 

Last ned en komplett deleliste i PDF:

  • 6.7440.170
    NIRS SingleFiber optical fiber, 2 m

    One-channel optical fiber in 2 m length for NIRS Process Analyzers

  • 6.7440.480
    NIRS Process, I/O Communication box

    I/O Communication box for process instruments with 24 analog and 24 digital channels

  • NIRS 99% reflection and wavelength standard process, 1 inch diameter
    6.7450.070
    NIRS 99% reflection and wavelength standard process, 1 inch diameter

    NIRS 99% reflection and wavelength standard for process instrument with 1 inch probe diameter

  • 6.7450.080
    NIRS 99% reflection and wavelength standard for process instrument, 0.5 inch probe diameter

    NIRS 99% reflection and wavelength standard for process instrument, 0.5 inch probe diameter

  • 6.7450.090
    NIRS 99% reflection and wavelength standard for process instrument, 1 inch diameter, 45° bevel