851 Titrando with Touch Control and generator electrode without diaphragm

851 Titrando with Touch Control and generator electrode without diaphragm
Artikkelnummer: 2.851.0120

Coulometer including generator electrode without diaphragm and Touch Control.

Coulometry is the ideal method for water determination in liquids, solids and gases when it comes to water determination in the trace range (10 µg to 10 mg absolute water). In addition, coulometry is an absolute method and thus no titer determination is necessary.

Coulometric titrations are carried out easily and quickly with the 851 Titrando.

Recommended measuring range: 10 µg - 200 mg absolute water

  • Dokumenter
  • Delebetegnelse
  • Tilleggsutstyr

Last ned en komplett deleliste i PDF:

  • Double Pt-wire electrode for coulometry
    6.0341.100
    Double Pt-wire electrode for coulometry

    Indicator electrode used for coulometric Karl Fischer titration.

    1 piece(s)

  • Generator electrode without diaphragm
    6.0345.100
    Generator electrode without diaphragm

    Generator electrode without diaphragm for coulometric Karl Fischer titrations, SGJ 29/22.
    This generator electrode is well suited for most applications where the sample is highly soluble in alcohol.

    1 piece(s)

  • KF adsorber tube for coulometer cell
    6.1403.030
    KF adsorber tube for coulometer cell

    For KF coulometers.


    1 piece(s)

  • SGJ stopper SGJ 14
    6.1437.000
    SGJ stopper SGJ 14

    1 piece(s)

  • Stopper / B-14/15 / M10
    6.1446.060
    Stopper / B-14/15 / M10

    1 piece(s)

  • Septum 16 mm, 5 pieces
    6.1448.020
    Septum 16 mm, 5 pieces
    Set of 5 pcs.

    2 piece(s)

  • KF titration vessel / 80-250 mL / coulometric
    6.1464.320
    KF titration vessel / 80-250 mL / coulometric

    1 piece(s)

  • Stirring bar / 25 mm
    6.1903.030
    Stirring bar / 25 mm

    Stirring bar with magnetic core, PTFE covering, length 25 mm.


    1 piece(s)

  • Holding clip for bottles
    6.2043.005
    Holding clip for bottles

    Holding spring for reagent bottles in exchange units.


    2 piece(s)

  • Titration vessel holder
    6.2047.020
    Titration vessel holder
    Titration vessel holder for coulometric cells.Used with 756, 831 KF Coulometer

    1 piece(s)

  • Adapter red  2 mm plug / 4 mm socket
    6.2103.130
    Adapter red 2 mm plug / 4 mm socket
    For connecting plug B (4 mm) to 2 mm socket.

    1 piece(s)

  • Adapter black 2 mm plug / B socket 4 mm
    6.2103.140
    Adapter black 2 mm plug / B socket 4 mm
    For connecting plug B (4 mm) to 2 mm socket.

    1 piece(s)

  • Electrode cable / 1 m / F
    6.2104.020
    Electrode cable / 1 m / F
    For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).

    1 piece(s)

  • Electrode cable / 1 m / H
    6.2104.120
    Electrode cable / 1 m / H
    With plug H. For connecting generator electrode - KF Coulometer.

    1 piece(s)

  • 
    GL 18 screw cap with hole
    6.2701.040
    GL 18 screw cap with hole
    Made of PBT. With a hole for the 6.1448.020 septum. For the 6.5405.000 cell without diaphragm and the 6.1464.32X and 6.1465.320 titration vessels.

    1 piece(s)

  • Sleeve
    6.2713.000
    Sleeve

    For the fat-free ground-joint connection with the standard ground-joint SGJ 14.


    3 piece(s)

  • Sleeve
    6.2713.010
    Sleeve

    Sleeve for the fat-free ground-joint connection with the standard ground-joint SGJ 29.


    1 piece(s)

  • Sleeve
    6.2713.020
    Sleeve

    For the fat-free ground-joint connection with the standard ground-joint SGJ 19.


    1 piece(s)

  • Stopper
    6.2730.030
    Stopper

    Complete with nipple and O-ring. For 6.1414.030 titration vessel lids. For KF instruments, VA measurement stands, VA Computrace and IC Dilution.

    1 piece(s)

  • Funnel
    6.2738.000
    Funnel

    For the KF coulometer.


    1 piece(s)

  • Molecular sieve
    6.2811.000
    Molecular sieve
    Molecular sieve. Bottle containing 250 g. Pore size: 0.3 nm. Without moisture indicator. For Rancimats and Karl Fischer instruments.

    1 piece(s)

  • Needle with Luer connector
    6.2816.030
    Needle with Luer connector

    Needle for filling in mercury into the Multi-Mode Electrode and for sample addition in Karl Fischer titration.


     


    2 piece(s)

  • Syringe 5 mL
    6.2816.090
    Syringe 5 mL

    5 mL syringe made of PP, with Luer connector.


    2 piece(s)

  • USB Memory Stick for 900 Touch Control 
    6.6064.010
    USB Memory Stick for 900 Touch Control 

    1 piece(s)

Last ned en komplett deleliste i PDF:

  • USB thermal printer Neo's
    2.141.0100
    USB thermal printer Neo's

    Compact printer with USB interface for the Ti-Touch, the Titrino plus and Dosimat plus and the 91X Meter instruments.

    Paper width 60 mm (40 characters). Including 6.2151.120 USB cable.