Applications
- 410000003-APortable Raman Spectroscopy for the Study of Polymorphs and Monitoring Polymorphic Transitions
Raman spectroscopy is used for material characterization by analyzing molecular or crystal symmetrical vibrations and rotations that are excited by a laser, and exhibit vibrations specific to the molecular bonds and crystal arrangements in the molecules. Raman technology is a valuable tool in distinguishing different polymorphs. Examples of portable Raman spectroscopy for identification of polymorphs and in monitoring the polymorphic transiton of citric acid and its hydrated form are presented.
- AN-EC-028Mesure de la perméabilité à l'hydrogène selon la norme ASTM G148
Dans cette note d'application, les expériences de perméation à l'hydrogène sont menées selon la procédure décrite dans la norme ASTM G148.
- AN-EC-031Suivi de l'oxydation du ferrocyanure à l'aide de l'EC-Raman
Cette note d'application met en évidence l'utilisation des solutions Metrohm Hyphenated EC-Raman pour surveiller l'oxydation réversible du ferrocyanure sur une électrode en or. Les variations de l'intensité des bandes en fonction du potentiel peuvent être utilisées pour suivre les changements relatifs du profil de concentration du ferrocyanure et du ferricyanure à la surface de l'électrode pendant la voltampérométrie cyclique (CV).
- AN-EC-032Hydrogen permeation with a single instrument according to ASTM G148
The Devanathan-Stachurski cell (or «H cell») is successfully used to evaluate the permeation of hydrogen through sheets or membranes. As small amounts of hydrogen pass through the sheet or membrane, a very sensitive potentiostat is required for its detection. A study of the hydrogen permeation properties of different iron sheets is discussed in this Application Note while taking the instrumental requirements into account.
- AN-EC-035Using a portable standalone system for easy fermentation monitoring
By using an enzymatic sensor with a screen-printed electrode, producers can measure lactic acid production, thereby monitoring fermentation processes.
- AN-EC-039Spectro-electrochemiluminescence study of simultaneous emission from two luminophores
Spectro electrochemiluminescence experiments comparing photodiode and microspectrometer detectors, showing how each sensor captures ECL signals for the analysis of single and dual luminophore systems.
- AN-FET-001Caractérisation et études de performance des transistors à effet de champ (FET) à l'aide de μStat-i 400.
Ces dernières années, les transistors à effet de champ (FET) ont été de plus en plus utilisés comme plate-forme de détection pour une multitude d'applications électrochimiques et biologiques. Ces dispositifs sont des transducteurs bioélectroniques prometteurs qui permettent à la fois un fonctionnement à faible potentiel et des mesures potentiométriques stables. Dans la communauté scientifique, les FET sont désormais considérés comme une alternative intéressante aux systèmes de détection électrochimique conventionnels. Cette note d'application donne des indications approfondies sur le fonctionnement des bipotentiostats Metrohm DropSens pour la caractérisation des FET et leur utilisation en tant que transducteurs. Un seul appareil μStat-i 400, un bipotentiostat et galvanostat petit et portable, est utilisé pour démontrer les expériences.
- AN-FLU-002Understanding the mechanism of a bioassay indicator by fluorescence
Alamar Blue is monitored with fluorescence spectroelectrochemistry during its irreversible reduction to resorufin and further reversible reduction to dihydroresorufin.
- AN-NIR-089Contrôle de la qualité des stratifiés
Dans l'industrie des semi-conducteurs, les résines thermodurcissables combinées à du tissu ou du papier sont utilisées comme couche intermédiaire entre les substrats des cartes de circuits imprimés (PCB). Ces feuilles à base de polymères (laminés) sont choisies en fonction de leur épaisseur et de leurs caractéristiques thermomécaniques et électriques.La spectroscopie proche infrarouge (NIRS) est une méthode d'analyse rapide, non destructive et facile à utiliser qui permet de mesurer plusieurs paramètres de qualité clés en moins d'une minute. La note d'application suivante décrit la détermination du temps de transition des stratifiés de PCB par NIRS, un paramètre en corrélation avec l'épaisseur, la température de transition vitreuse et la résistance à la traction du matériau.
- AN-NIR-093Contrôle de la qualité des processus de fermentation
La production de biocarburants à partir de matières premières renouvelables a connu un essor considérable au cours des dernières années. Le bioéthanol est l'une des alternatives les plus intéressantes aux combustibles fossiles, car il peut être produit à partir de matières premières riches en sucres et en amidon. La fermentation de l'éthanol est l'un des processus de fermentation les plus anciens et les plus importants utilisés dans l'industrie biotechnologique. Bien que le processus soit bien connu, il existe un grand potentiel d'amélioration et de réduction proportionnelle des coûts de production. En raison des variations saisonnières de la qualité des matières premières, les producteurs d'éthanol doivent surveiller le processus de fermentation pour s'assurer que le produit obtenu est de même qualité. La spectroscopie proche infrarouge (NIRS) permet une prédiction rapide et fiable de la teneur en éthanol, en sucres, en Brix, en acide lactique, en pH et en solides totaux à n'importe quel stade du processus de fermentation.
- AN-NIR-099Quality Control of fermentation broths
Cell fermentation processes are a reliable production method for small molecules and protein-based active pharmaceutical ingredients (APIs). The fermentation process requires monitoring of many different parameters to ensure optimal production. These quality parameters include pH, bacterial content, potency, glucose, and concentration of reducing sugars. Traditional laboratory analysis takes a significant amount of time and requires different analytical techniques to monitor these different quality parameters. Near-infrared spectroscopy (NIRS) offers a faster and more cost-efficient alternative to traditional methods for the determination of critical parameters in fermentation broths at any stage of the fermentation process.
- AN-RA-004UV/VIS spectroelectrochemical monitoring of 4-nitrophenol degradation
Spectroelectrochemistry is a multi-response technique that provides both electrochemical and spectroscopic information about a chemical system in a single experiment, i.e., it offers information from two different points of view. Spectroelectrochemistry focused on the UV/VIS region is one of the most important combinations because this allows us to obtain not only valuable qualitative information, but also outstanding quantitative results. In this application note, the degradation kinetics for 4-nitrophenol, a known pollutant, were determined using SPELEC.
- AN-RA-005Characterization of single-walled carbon nanotubes by Raman spectroelectrochemistry
Spectroelectrochemistry is a multi-response technique that provides electrochemical and spectroscopic information about a chemical system in a single experiment, i.e., it offers information from two different points of view. Raman spectroelectrochemistry could be considered as one of the best techniques for both the characterization and behavioral understanding of carbon nanotube films, as it has traditionally been used to obtain information about their oxidation-reduction processes as well as the vibrational structure. This application note describes how the SPELEC RAMAN is used to characterize single-walled carbon nanotubes by studying their electrochemical doping in aqueous solution as well as to evaluate their defect density.
- AN-RS-042Revealing battery secrets with EC-Raman solutions
Electrochemical Raman (EC-Raman) spectroscopy enhances comprehension of energy storage devices by tracking physicochemical changes. This note details EC-Raman findings during nickel-metal hydride (NiMH) battery charge and discharge simulations.
- EB-001Spectroscopie proche infrarouge pour l'analyse des produits pétrochimiques
Améliorez le contrôle qualité dans le secteur pétrochimique grâce à la technologie NIRS. Rapide, économique et sans préparation d'échantillons. Pour en savoir plus, consultez notre eBook.
- EB-002Spectroscopie NIR : un gain d'efficacité pour les laboratoires de contrôle qualité
Améliorez le contrôle qualité dans la production de matériaux et de produits chimiques grâce à la technologie NIRS. Rapide, économique et sans préparation d'échantillons. Pour en savoir plus, consultez notre eBook.
- EB-004Spectroscopie proche infrarouge et Raman pour l'analyse des polymères : Une introduction
Ce livre électronique explique comment les spectroscopies Raman et proche infrarouge (NIR) permettent une analyse rapide et non destructive des polymères, garantissant une qualité élevée tout en réduisant les coûts et les déchets.
- WP-046Surmonter la limitation de l'eau en spectroélectrochimie NIR
La spectroscopie proche infrarouge NIR est traditionnellement limitée du fait de l'absorption d'eau dans cette gamme spectrale. C'est ainsi que la bien connue restriction due à l'eau a limité le développement de nouvelles applications pour la spectroélectrochimie NIR. Cette étude propose différentes alternatives intéressantes pour réduire ou même éliminer la contribution aqueuse dans cette gamme spectrale.
- WP-054Booster l'efficacité en laboratoire de contrôle qualité ou comment la NIRS permet de réduire jusqu'à 90 % des coûts
La sous-estimation des procédures de contrôle qualité (CQ) est l'un des principaux facteurs entraînant une défaillance interne et externe des produits, dont il est rapporté qu'elle aurait provoqué entre 10 et 30 % de pertes de chiffre d'affaires. En conséquence, bon nombre de normes ont été mises en place pour assister les fabricants dans leur procédure de contrôle qualité. Cependant, le temps de résultat et les coûts associés aux produits chimiques peuvent être parfois excessifs, ce qui conduit de nombreuses entreprises à introduire la spectroscopie proche infrarouge (NIRS) dans leur procédure de contrôle qualité. Cet article montre les possibilités offertes par la spectroscopie proche infrarouge et indique des économies potentielles pouvant atteindre 90 % des coûts.
- WP-055Meilleures pratiques en matière de corrosion – Création de conditions d'écoulement dans des conduits à l'aide d'une électrode à cylindre tournant
Les mesures électrochimiques avec électrode à cylindre tournant (RCE) sont largement employées dans les applications industrielles sur la corrosion lorsque la simulation réaliste des conditions d'écoulement dans des conduits est nécessaire en laboratoire. Ce livre blanc permet de mieux comprendre les particularités et les paramètres qui régissent les mesures électrochimiques, en particulier les mesures effectuées dans des conditions d'écoulement turbulent, et donne un tableau exhaustif des meilleures pratiques d'application de cette technique. Les annexes fournissent un aperçu et une brève explication des paramètres et des lois spécifiques au comportement des fluides dans les cellules électrochimiques avec RCE.