Sovellukset
- 8.000.6020Titrimetric analyses of biofuels
Several testing methods such as the determination of the acid and the iodine numbers in biodiesel as well as the quantification of sulfate and chloride in bioethanol are described.
- 8.000.6066Determination of the total acid number (TAN) using thermometric titration
The thermometric titration method presented here permits a simple and direct determination of the total acid number (TAN) in petroleum products. It is an invaluable alternative to current manual and potentiometric methods. Thermometric titration uses a maintenance-free temperature sensor that does not require rehydration and is free of fouling and matrix effects. The procedure requires minimal sample preparation. Results agree closely with those from the potentiometric titrimetric procedure according to ASTM D664, but the thermometric titration method is far superior in terms of reproducibility and speed of analysis, with determinations being complete in approximately one minute.
- 8.000.6080Thermometric titration – the missing piece of the titration puzzle
Thermometric titration can solve application problems that potentiometry cannot solve at all, or at least not satisfactorily.
- AB-141Analysis of edible fats and oils – The seven most important parameters for quality control
As the determination of the exact content of individual glycerides in fats and oils is difficult and time-consuming, several fat sum parameters or fat indices are used for the characterization and quality control of fats and oils. Fats and oils are not only essential for cooking, they are also an important ingredient in pharmaceuticals and personal care products, such as ointments and creams. Consequently, several norms and standards describe the determination of the most important quality control parameters. This Application Bulletin describes eight important analytical methods for the following fat parameters in edible oils and fats:Determination of water content in accordance with the Karl Fischer method; Oxidation stability in accordance with the Rancimat method; Iodine value; Peroxide value; Saponification value; Acid value, free fatty acids (FFA); Hydroxyl number; Traces of nickel using polarography; Special care is taken to avoid chlorinated solvents in these methods. Also, as many of the mentioned methods as possible are automated.
- AB-200Acid value, hydroxyl value, and isocyanates in raw materials for the fabrication of plastics – Determination by automatic potentiometric titration according to various standards
Polyurethanes are one of the most commonly used types of plastic. They are produced by the reaction of raw polyols with isocyanates. Depending on the starting material a wide variety of plastics can be obtained. The determination of the acid value, hydroxyl value, and isocyanate content plays an important part in the analysis of raw materials for plastics.The acid number of polyol raw material is usually used in quality control to ensure batch-to-batch uniformity. Additionally it is used as correction factor for calculating the true hydroxyl number. In this Application Bulletin the determination of the acid number according to ASTM D4662 and ASTM D7253 is described.One raw material for polyurethanes are polyols. Polyols contain multiple hydroxyl groups. Therefore, hydroxyl number of a raw material directly correlates to the amount of polyols present and it is thus an important quality control parameter. In this Application Bulletin the determination of the hydroxyl number according to ASTM E1899 and DIN 53240-3 is described.As polyols react stoichiometrically with isocyanates, the knowledge of the isocyanate content is an important quality parameter for the production of polyurethanes. In this document the determination according to EN ISO 14896 method A, ASTM D5155 method A and ASTM D2572 is described.
- AB-206Titer determination in potentiometry
This Bulletin provides an overview of the potentiometric titer determination of current titrants. Many publications only describe methods with color indicators. However, the titration conditions chosen for the titer determination should resemble those used for the actual analysis as closely as possible. The tables contain suitable titrimetric standard substances and electrodes for selected titrants as well as additional information. Following this, an example is given to show what an SOP for a titer determination could look like.
- AB-404Total acid number titration of petroleum products
The determination of the acid number plays a significant role in the analysis of petroleum products. This is manifested in the numerous standard procedures in use over the world (internal specifications of multinational companies, national and international specifications of ASTM, DIN, IP, ISO, etc.). These procedures differ mainly in the composition of the used solvents and titrants.This bulletin describes the determination of the acid number in petroleum products by applying different types of titration.The potentiometric determination is described according to ASTM D664, the photometric according to ASTM D974 and the thermometric titration according to ASTM D8045.
- AB-405Total base number titration of petroleum products
This Application Bulletin shows the determination of the total base number in petroleum products by applying different titration types according to various standards.
- AB-427Acid number in petroleum products with thermometric titration
This Application Bulletin describes the determination of the total acid number in various oil samples by catalytic thermometric titration as per ASTM D8045.
- AN-H-001Determination of TAN in oils
Determination of Total Acid Number (TAN) values in mineral oils and similar fluids.
- AN-H-060Standardization of 0.1 mol/L perchloric acid in glacial acetic acid
Standardization of 0.1mol/L perchloric acid in glacial acetic acid by catalyzed endpoint thermometric titration.
- AN-H-064Total base number (TBN) in used motor oils
The determination of the total base number (TBN) in motor oils is accomplished by means of titration with a standard solution made up of trifluoromethanesulfonic acid in glacial acetic acid and isobutyl vinyl ether as reagent for improved end point identification.
- AN-H-073Determination of total acid number (TAN) in biodiesel
Determination of Total Acid Number (TAN) values in biodiesel to <0.05 mg KOH/g sample.
- AN-H-088Automated determination of total acid number (TAN) in oils
Automated determination of total acid number (TAN) in new and used lubricating oils and crude oils using the 814 USB Sample Processor. Dissolve oil sample in mixture of toluene and 2-propanol, add paraformaldehyde and titrate with 0.1 mol/L or 0.01 mol/L KOH in propan-2-ol. The endpoint is indicated by an endothermic response caused by the base-catalyzed depolymerization of paraformaldehyde.Reference: 1. M. J. D. Carneiro, M. A. Feres Júnior, and O. E. S. Godinho. Determination of the acidity of oils using paraformaldehyde as a thermometric end-point indicator. J. Braz. Chem. Soc. 13 (5) 692-694 (2002)
- AN-H-096Determination of total base number of lubricating oils
Dissolution of oil in toluene, and titration with standard 0.1 mol/L trifluoromethanesulfonic acid in acetic acid using isobutyl vinyl ether as a thermometric endpoint indicator.
- AN-H-100Determination of total acids in highly acidic etch solutions
Determination of the total acids concentration in mixtures of nitric-hydrofluoric acid intended for etching silicon substrates.
- AN-H-141Acid number in crude oil and gas oil according to ASTM D8045
Thermometric titration can determine the total acid number (TAN) of various crude oil products according to ASTM D8045 without requiring any sensor maintenance.
- AN-NIR-023Quality Control of PET
Determination of the diethylene glycol content, isophthalic acid content, intrinsic viscosity (ASTM D4603), and the acid number (AN) of polyethylene terephthalate (PET) is a lengthy and challenging process due to the sample’s limited solubility and the need to use different analytical methods. This application note demonstrates that the DS2500 Solid Analyzer operating in the visible and near-infrared spectral region (Vis-NIR) provides a cost-efficient and fast solution for a simultaneous determination of these parameters in PET. Vis-NIR spectroscopy allows for the analysis of PET in less than one minute without sample preparation or using any chemical reagents.
- AN-NIR-035Quality control of polyols with NIRS
Polyols are widely used as polyurethane feedstocks, where tight quality control of parameters such as hydroxyl value, acid number, moisture, and viscosity is essential. Conventional titration methods are standardized but slow and costly due to hazardous chemicals and waste handling. Near-infrared spectroscopy (NIRS), recognized by ASTM for hydroxyl value determination, enables rapid, reagent-free, multiparameter analysis of polyols with significantly lower operating costs.
- AN-NIR-041Multiparameter Quality Control of Lubricants with NIRS
For lubricant analysis, determination of the Acid Number (ASTM D664), viscosity (ASTM D445), moisture content (ASTM D6304), and color number (ASTM D1500) require the use of multiple analytical technologies and, in part, large volumes of chemicals. This application note demonstrates that the XDS RapidLiquid Analyzer operating in the visible and near-infrared spectral region (Vis-NIR) provides a fast and cost-efficient alternative for the determination of the AN, viscosity, moisture content, and color number of lubricants. With no sample preparation or chemicals needed, Vis-NIR spectroscopy allows for multi parameter analysis of lubricants in less than one minute.
- AN-NIR-043Analytical data transfer between a Fourier transform and a dispersive NIR instrument
This Application Note demonstrates the data transfer from a Fourier transform to a dispersive NIR instrument, using quality control of lubricating oils as an example application. It is shown that FT-NIR instruments can be replaced by dispersive ones without time-consuming sample remeasurement and subsequent method development.
- AN-NIR-071Automated acid number determination in lubricants with near-infrared spectroscopy
Acid Number (AN) analysis of lubricants (ASTM D664) can be a lengthy and costly process due to usage of large amounts of chemicals and required cleaning steps of the analytical equipment between each measurement. This application note demonstrates that the XDS RapidLiquid Analyzer operating in the visible and near-infrared spectral region (Vis-NIR) provides a cost-efficient, fast alternative for the determination of the acid number of lubricants. With no sample preparation or chemicals needed, Vis-NIR spectroscopy allows for the analysis of AN in less than a minute.
- AN-NIR-097Total base number in lubricants with near-infrared spectroscopy
Alkaline additives in engine lubricants are used to prevent the build-up of acids and as a result, they inhibit corrosion. The total base number (TBN) indicates the amount of basic additives present in samples and thus can be used as a measure for the degradation of the lubricant. The standard test method for TBN in lubricants is potentiometric titration according to ASTM D2896. This method requires the use of toxic reagents involves a labor-intensive cleaning procedure. In contrast to the primary method, near-infrared spectroscopy (NIRS) is a fast analytical technique which does not produce any chemical waste and completes the TBN analysis in less than one minute.
- AN-NIR-150Monitoring the production of stearic acid and its salts with NIR spectroscopy
Stearic acid and stearate derivatives are produced through multistep processing and require monitoring of key quality attributes, including iodine value, acid value, moisture, ash content, melting point, and granulometry. This study demonstrates that near-infrared (NIR) spectroscopy with the OMNIS NIR Analyzer enables rapid, nondestructive quantitative analysis of these parameters for both in-process and final-product samples.
- AN-PAN-1037Online measurement of the acid number (AN) in oils with thermometric titration (ASTM D8045)
Online acid number analysis in various oil products is possible with thermometric catalytic titration according to ASTM D8045 using the 2060 TI Ex Proof Process Analyzer.
- AN-PAN-1041Inline monitoring of free isocyanate (%NCO) content in polyurethane
Polyurethanes are a class of synthetic polymers formed by reacting liquid di/polyisocyanates and polyols with a catalyst and various additives in a reactor. Polymer properties are modified with stepwise additions of these chemicals at different points in time depending on whether the process has reached an equilibrium. NCO functional groups from unreacted isocyanates must be quenched at the end for a finished product, and this parameter must be known to determine the proper chemical mixing ratio. A fast, non-destructive real-time measurement of %NCO can be obtained by using NIR spectroscopy with a probe seated directly in the reactor.
- AN-PAN-1053Monitoring of DOTP production via esterification with inline analysis
This Process Application Note presents a way to closely monitor multiple parameters simultaneously during the dioctyl terephthalate production process with near-infrared spectroscopy.
- AN-T-092Acid number in insulating, transformer and turbine oils – Use of a photometric sensor increases precision and reliability for the determination according to ASTM D974
The acid number (AN) of insulating, transformer, and turbine oils is crucial to ensure safe operation, operating equipment control, and corrosion prevention. These oils generally have low AN specifications and their AN determination by manual color-indicator titration is difficult, especially when analyzing colored samples.Using a Titrator with a photometric sensor to detect the end point ensures that the titrations are always carried out under the same conditions. This greatly increases the precision and reliability of the results, which in turn results in improved monitoring for your operations.
- AN-T-093Total base number in used engine oil – Fully automatic photometric determination increases reliability of results
Basic additives are added to petroleum products to inhibit corrosion as they have a neutralizing effect on acidic compounds, which are formed as a result of degradation processes. Total base number (TBN) indicates the amount of basic additives present and thus can be used as a measure for the degradation of the petroleum product.Using an automated titration system with a photometric sensor to detect the end point ensures that the titrations are always carried out under the same conditions. This improves the precision and reliability of the results.This Application Notes describes the fully automated photometric determination of TBN in used engine oil using the Metrohm Optrode for the indication of the methyl orange endpoint (at 520 nm).
- AN-T-095Automated mixing of a suspension and a solvent using a 50 mL dosing unit
Automated mixing of a suspension and a solvent in a 50 mL dosing unit can be used to add a well-defined amount of a suspension-solvent mixture to a sample solution without clogging the dosing unit and tubing by the undiluted suspension.The method is explained by means of the TAN determination of a petroleum sample using thermometric titration. For a better endpoint recognition, small amounts of a paraformaldehyde-solvent suspension are added (catalyzed endpoint thermometric titration).
- AN-T-096Acid number in lubricants with potentiometric titration
Fresh as well as used petroleum products may contain acidic components as additives or degradation products. The acid number (AN) is a measure for the relative amount of acids present expressed as mg KOH per g sample. Moreover, AN is used as a quality parameter of lubricating oils both for assessing the quality of new formulations and as an indicator for the degradation of such formulations during service. The use of a pH electrode suitable for non-aqueous titrations ensures the reliable determination of the equivalence point. A flexible sleeve diaphragm facilitates its cleaning especially after use in heavily contaminated samples, such as in used engine oils. Using the correct electrode greatly increases the precision and reliability of the results. This Application Note describes the potentiometric determination of the acid number according to ASTM D664 and IP 177 using the pH electrode Solvotrode easyClean.
- AN-T-097Base number in petroleum products with potentiometric titration
Basic chemicals are added to petroleum products to prevent corrosion as they neutralize acidic components that form during the use and aging of these products. The base number (BN) gives an indication regarding the amount of these basic additives present, and it can be used as a measure for the degradation of the petroleum product.This Application Note describes the potentiometric determination of the base number according to ISO 3771, ASTM D2896, and IP 276 using the Metrohm Solvotrode easyClean and a fully automated OMNIS system.
- AN-T-098Total base number according to IP test method 400
This Application Note describes the conductometric determination of the total base number in engine oil according to IP 400.
- AN-T-099Fully automated determination of acidity in orange juice
The present Application Note describes an automated system with which the acidity can be determined in a wide variety of juice samples. The high degree of automation (e.g., automated calibration and titer determination) reduces errors to a minimum and offers outstanding reproducibility.
- AN-T-159Basicity and CPR in polyols according to ISO 14899
The basicity and the CPR (controlled polymerization rate) are very important parameters for the quality of polyols used in polyurethane production. The knowledge of these values is crucial to prevent gelation during handling in the production. In this Application Note their determination by automated, potentiometric titration according to ISO 14899 is described.
- AN-T-160Determination of the acid number in acrylic acid
Acrylic acid dimerizes spontaneously. Determining the dimer content is, therefore, a key part of the quality control for acrylic acid. One quality control parameter for the dimerization is the acid number. This Application Note describes its determination by automated, potentiometric titration.
- AN-T-164Partial acid number in unsaturated polyester resin according to EN ISO 2114
The partial acid number (also partial acid value) describes the quantity of potassium hydroxide that is required for neutralizing all carboxyl-terminated groups and free acids plus half the anhydride groups in an unsaturated polyesterresin (UPR). This Application Note describes the determination of the partial acid value by automatic, potentiometric titration according to EN ISO 2114 using KOH in ethanol as titrant.
- AN-T-165Total acid number in unsaturated polyester resin according to EN ISO 2114
The total acid number (TAN) indicates the amount of potassium hydroxide required for neutralizing all carboxyl-terminated groups and free acids plus the free anhydride groups in an unsaturated polyester resin (UPR). In this Application Note the TAN determination using automated, potentiometric titration according to EN ISO 2114 using KOH in ethanol as titrant is described.
- AN-T-179Fully automated determination of TAN/TBN according to ASTM D664 and ASTM D2896
Fully automated determination of the total acid number and total base number in engine oils according to ASTM D664 and ASTM D2896 is possible with the OMNIS Titrator.
- AN-T-199Photometric determination of acidity in ethanol according to ASTM D7795
Denatured fuel ethanol may contain additives such as corrosion inhibitors and detergents as well as contaminants from manufacturing that can affect the acidity of produced ethanol fuel. An increased acid content in solvents could lead to a variety of problems like a shorter storage stability or chemical corrosion. Using the Optrode with phenolphthalein as indicator, the acidity is determined as acetic acid by titration with sodium hydroxide as titrant.
- AN-T-200Potentiometric determination of acidity in ethanol according to ASTM D7795
Denatured fuel ethanol may contain additives such as corrosion inhibitors and detergents as well as contaminants from manufacturing that can affect the acidity of produced ethanol fuel. An increased acid content in solvents could lead to a variety of problems like a shorter storage stability or chemical corrosion.Using the dSolvotrode for indication, the acidity is determined as acetic acid by titration with sodium hydroxide as titrant.
- AN-T-203Acidity in volatile solvents and chemical intermediates
The presence of acidic components in volatile solvents could be a result of contamination, decomposition during storage, distribution or manufacture. An increased acid content in solvents could lead to a variety of problems like shorter storage stability or chemical corrosion. Using the Optrode for indication, the acidity is determined by photometric titration with sodium hydroxide as titrant and phenolphthalein as indicator. If the volatile solvent is water soluble, it is dissolved in deionized water, if not, it is dissolved in carbon-dioxide free ethanol.
- AN-T-240Total acid number with conductometric titration
The total acid number (TAN) is an important parameter for assessing the acidity of oils and fuels. This Application Note determines TAN using conductometric titration.
- AN-T-247Photometric titration of acid value in biodiesel according to EN 14104
The acid value of fatty acid methyl esters (FAME) like biodiesel can be determined according to EN 14104 using photometric titration with OMNIS and the Optrode.
- EB-001Near-infrared spectroscopy for the analysis of petrochemicals
Improve petrochemical quality control with NIRS. Fast, cost-effective, and no sample prep needed. Learn more in our eBook.
- EB-002NIR spectroscopy: The efficiency boost for QC labs
Enhance quality control in material and chemical production with NIRS. Fast, cost-effective, and no sample prep needed. Learn more in our eBook.
- EB-004Near-infrared and Raman spectroscopy for polymer analysis: An introduction
This e-book explains how Raman and near-infrared (NIR) spectroscopy enable rapid, nondestructive polymer analysis, ensuring high quality while reducing costs and waste.
- WP-012Corrosion control: Thermometric TAN analysis in oil & refinery distillation fractions
Many refiners look at discounted opportunity crudes as a means to improve their margin spread. The varieties of these cheap crude oils on the market are growing in number, but they have hidden risks for the purchaser caused by factors such as high naphthenic acid and sulfur content. Sulfur compounds and naphthenic acids are among the substances that contribute to the corrosive nature of crude oils and petroleum products. This is why the risk of corrosion is increased when processing crude oils with high naphthenic acid and sulfur content. The refiner must balance the cost benefit versus the risk and the cost of corrosion control when processing these crudes. A reliable acid number determination is a crucial part of corrosion control. Guest authors Bert Thakkar, Bryce McGarvey, and Colette McGarvey of Imperial Oil and Larry Tucker and Lori Carey of Metrohm USA were involved in the development of the new ASTM Method D8045 for acid number determination. Here, they report on the method and how it came to be.
- WP-053Determination of Acid Number (AN) with Titration and NIR Spectroscopy
The acid number (AN) is a measure for the quality of oils and their potential to enhance corrosion. When analyzing fresh, unused oils, the AN is used to ensure the specified quality from the manufacturer, whereas for used oils the AN is determined to observe its increase until a critical level is reached. Although it is generally assumed that the AN correlates to the corrosive potential of the oil, this is not exactly correct, as it is the change of the AN value which indicates this issue. Therefore it is necessary to determine the AN on a regular basis.Several standards already exist to determine AN via titration methods, however it is also possible to measure this parameter via spectroscopic (NIRS) methodology. No matter which technique you choose, Metrohm has you covered with high-performance instruments suitable for these published norms.
- WP-054Boost efficiency in the QC laboratory: How NIRS helps reduce costs up to 90%
Underestimation of quality control (QC) processes is one of the major factors leading to internal and external product failure, which have been reported to cause a loss of turnover between 10–30%. As a result, many different norms are put in place to support manufacturers with their QC process. However, time to result and the associated costs for chemicals can be quite excessive, leading many companies to implement near-infrared spectroscopy (NIRS) in their QC process. This paper illustrates the potential of NIRS and displays cost saving potentials up to 90%.