Applications
- AN-S-091Gluconate, fluoride, chloride, nitrate, and salicylate in a standard solution
Determination of gluconate, fluoride, formate, chloride, nitrate, and salicylate using anion chromatography with conductivity detection after chemical suppression.
- AN-S-131Determination of lactate, acetate, chloride, methylsulfate, bromide, and sulfate
Determination of lactate, acetate, chloride, methylsulfate, bromide, and sulfate using anion chromatography with conductivity detection after chemical suppression.
- AN-S-134Trace anions in the presence of 1 g/L of chloride
Determination of bromide, sulfate, and iodide in 1 g/L sodium chloride using anion chromatography with conductivity detection after chemical suppression.
- AN-S-138Polyphosphates in the presence of standard anions
Determination of pyro-, trimeta-, and tripolyphosphate in the presence of fluoride, chloride, nitrite, bromide, nitrate, phosphate, and sulfate using anion chromatography with a high pressure gradient and conductivity detection after chemical suppression.
- AN-S-139Sulfite, oxalate, thiosulfate, and thiocyanate in the presence of standard anions
Determination of sulfite, oxalate, thiosulfate, and thiocyanate in the presence of fluoride, chloride, nitrite, bromide, nitrate, phosphate, and sulfate using anion chromatography with a high pressure gradient and conductivity detection after chemical suppression.
- AN-S-140Iodide, thiosulfate, and thiocyanate in the presence of standard anions
Determination of iodide, thiosulfate, and thiocyanate in the presence of fluoride, chloride, nitrite, bromide, nitrate, phosphate, and sulfate using anion chromatography with a high-pressure gradient and conductivity detection after chemical suppression.
- AN-S-154Eleven anions with high pressure gradient elution
Determination of fluoride, chloride, nitrite, bromide, nitrate, phosphate, sulfate, oxalate, thiosulfate, iodide, and citrate in a standard solution using anion chromatography with a high pressure gradient and conductivity detection after chemical suppression.
- AN-S-159Arsenic and selenium speciation using «High-Low» Detection
Determination of arsenite, arsenate, selenite, selenate, chloride, and sulfate using anion chromatography with a combination of suppressed and non-suppressed conductivity detection.
- AN-S-195Anions and organic acids with high pressure gradient
Determination of 21 anions and organic acids using anion chromatography with conductivity detection after chemical suppression and applying a high pressure gradient.
- AN-S-199Selenite and selenate in the presence of the standard anions
Determination of fluoride, chloride, nitrite, selenite, phosphate, nitrate, sulfate, and selenate using anion chromatography with conductivity detection after chemical suppression.
- AN-S-201Eight anions separated on column Metrosep A Supp 1
Determination of formate, chloride, nitrite, phosphite, phosphate, sulfite, nitrate, and sulfate using anion chromatography with conductivity detection after chemical suppression.
- AN-S-205Traces of perchlorate in samples with a high ionic background applying heart-cut technique
Determination of traces of perchlorate in a sample with a high salt load using anion chromatography with conductivity detection after chemical suppression.
- AN-S-232Chloride and sulfate in electrolytes used in sensors for transcutaneous CO2 measurement
Determination of chloride and sulfate in an electrolyte used in sensors for transcutaneous CO2 measurement using anion chromatography with conductivity detection after chemical suppression.
- AN-S-234Oxohalides and monovalent organic acids in the presence of standard anions
Determination of chlorite, bromate, chlorate, glycolate, acetate and formate in the presence of fluoride, chloride, nitrite, bromide, nitrate, phosphate and sulfate using anion chromatography and subsequent conductivity detection following chemical suppression.
- AN-S-238Sulfur species with «High–Low Detection»
Determination of sulfide, sulfite, sulfate, and thiosulfate in the presence of chloride, nitrate, and phosphate using anion chromatography with combination of suppressed and nonsuppressed conductivity detection.
- AN-S-254MISP – Metrohm Inline-Ultrafiltration – Cross Contamination < 0.1%
Determination of the cross contamination of 100 mg/L of fluoride, chloride, nitrite, bromide, nitrate, phosphate, and sulfate to ultrapure water using anion chromatography with conductivity detection after chemical suppression and inline ultrafiltration.
- AN-S-255Sixteen anions separated on the column Metrosep A Supp 7 - 250/4.0 using gradient elution
Determination of fluoride, hypophosphite, chlorite, bromate, chloride, nitrite, bromide, chlorate, nitrate, phosphite, phosphate, sulfate, arsenate, iodide, chromate, and perchlorate using anion chromatography with conductivity detection after gradient elution and chemical suppression.
- AN-S-256Thirteen anions separated on the column Metrosep A Supp 7 - 250/4.0
Determination of fluoride, hypophosphite, chlorite, bromate, chloride, nitrite, bromide, chlorate, nitrate, phosphite, phosphate, sulfate, and iodide using anion chromatography with conductivity detection after chemical suppression.
- AN-S-259Phosphate and citrate separated on the column Metrosep A Supp 15 - 100/4.0
Determination of chloride, nitrate, sulfate, phosphate, and citrate using anion chromatography with conductivity detection after chemical suppression.
- AN-S-264Inline eluent preparation for anion analysis
Long-term determination of standard anions with automatic inline eluent preparation applying Dosino and Level Control technology using anion chromatography with conductivity detection after sequential suppression.
- AN-S-269MiPT – Metrohm intelligent Partial Loop Injection Technique
Calibration of fluoride, chloride, nitrite, bromide, nitrate, phosphate, and sulfate using intelligent partial loop injection technique and anion chromatography with conductivity detection after sequential suppression. This technique allows a calibration range of 1:100 (e.g. 1 μg/L to 100 μg/L corresponding to 2 μL to 200 μL injected volume) out of 1 calibration solution. Applying the full range of partial loop injection to the samples one calibration covers a sample concentration range of 1 to 10'000.
- AN-S-270Impurities in syringe filters – Anions
Determination of fluoride, acetate, formate, chloride, nitrite, nitrate, phosphate, and sulfate impurities in syringe filters using anion chromatography with conductivity detection after sequential suppression.
- AN-S-275Formate, acetate, oxalate, and molybdate in the presence of standard anions
Determination of fluoride, formate, acetate, chloride, nitrite, bromide, nitrate, sulfate, oxalate, and molybdate using anion chromatography with conductivity detection after chemical suppression and Metrohm Inline Dialysis.
- AN-S-277Hexafluorosilicate in the presence of standard anions
Determination of fluoride, chloride, nitrate, phosphate, sulfate, silicate, and hexafluorosilicate (calculated) using anion chromatography with conductivity detection after chemical suppression and subsequent UV/VIS detection with post-column reaction (see AN U-48). Hexafluorosilicate is hydrolyzed into fluoride and silicate. Both anion concentrations can be used for the calculation of the SiF62- concentration.
- AN-S-279Perchlorate and thiosulfate separated on a guard column
Determination of perchlorate and thiosulfate using anion chromatography with conductivity detection after sequential suppression.
- AN-S-291Reproducibility of the Metrohm Suppressor Module (MSM)
The state-of-the-art tri-chamber suppressor technology provides a fresh suppressor chamber for each measurement. The complete regeneration of the chamber after each sample ensures highly efficient cation exchange – today, tomorrow, and even after years of continuous operation.The chromatograms as well as the statistical data demonstrate the outstanding reproducibility of the measurements with the Metrohm Suppressor Module.
- AN-S-296Anion Inline Eluent Preparation using an 849 Level Control
Eluent preparation on demand (EPOD) is the convenient and flexible way of automatic eluent preparation. The 849 Level Control together with an 800 Dosino equipped with a 50 mL dosing unit are used to dilute an eluent concentrate to the final eluent concentration. The use of eluent concentrates is suitable for any type of eluent. This facilitates unattended operation of the system over several weeks (see AN C-134 for cation eluent preparation).
- AN-S-304Variable Inline Preconcentration including Matrix Elimination for trace anion analysis (MiPCT-ME)
Metrohm Inline Preconcentration Technique with Matrix Elimination (MiPCT-ME) is a powerful tool that combines preconcentration, matrix elimination, and multilevel calibration. The latter only requires a single multi-ion standard solution. The 800 Dosino takes over all liquid handling tasks. The shown system setup allows sample analysis from 0.1 µg/L up to 1.0 mg/L.
- AN-S-318Fast IC: Separation of standard anions in three minutes
Fast IC means a high sample throughput. This is attained with short columns, relatively high flows and strong eluents. Here standard anions are determined within three minutes on the Metrosep A Supp 10 - 50/4.0.
- AN-S-319Fast IC: separation of organic acid anions as well as sulfate in three minutes
Fast IC means a high sample throughput. This is attained with short columns, relatively high flows and strong eluents. Malate, tartrate, oxalate as well as sulfate are separated within three minutes.
- AN-S-322Fast IC: Standard anions and oxalate in less than eight minutes.
Fast IC means short run times and a high sample throughput. This is attained using short columns and strong eluents. Fluoride, chloride, nitrate, phosphate, sulfate and oxalate are separated in less than eight minutes using the Metrosep A Supp 5 - 100/4.0.
- AN-S-331Separation of seven standard anions with the Metrosep A Supp 5 microbore anion column
The Metrosep A Supp 5 microbore anion column is available in 150 and 250 mm lengths. For the two columns, the run times for separating the 7 standard anions are 20 and 29 minutes. In addition to the good separation properties and the short running times, microbore columns use approximately 75% less eluent than does their 4 mm counterpart.
- AN-S-334Thiosulfate, thiocyanate and perchlorate in addition to standard anions using a low-pressure gradient
Retention of thiosulfate, thiocyanate and perchlorate is strong on the Metrosep A Supp 5 - 250/2.0 column. A shorter run time for the separation of the anions mentioned along with standard anions is achieved using a low-pressure gradient.
- AN-S-33915 organic acids on the Metrosep A Supp 7 - 250/4.0 using a high-pressure gradient
High-pressure gradients combine the advantages of weak and concentrated eluents. Weak eluents promote the separation of the components that elute early and in close proximity to one another; in contrast to this, concentrated eluents accelerate the analysis of the components that are stronger retained at the column. The high-pressure gradient used in this application makes it possible to separate 15 organic acid anions in a single run. The blank subtraction option in the MagIC Net software simplifies the allocation of the peaks and with it the quantification.
- AN-S-350Parallel anion (and cation) analysis applying the Metrohm IC Driver 2.0 for Empower
Parallel anion and cation analysis is typically used when both anions and cation have to be analyzed. Here, the anion part of such an analysis is shown. The sample is injected to the anion channel from the 889 IC Sample Center by its built-in injector. The whole system is controlled by Empower applying the Metrohm IC Driver 2.0. For cation analysis, see AN-C-166.
- AN-S-363Combination of Inline Dilution with subsequent Inline Ultrafiltration and automatic calibration
Metrohm Inline Sample Preparation (MISP) is a collection of versatile, time- and cost- effective techniques reducing manual sample preparation. This Application Note describes the combination of Inline Dilution with Inline Ultrafiltration. Samples are automatically diluted and subsequently filtered before injection. MagIC Net allows to run intelligent dilution by checking results and rediluting the sample if the result is out of the calibration range. Also the multipoint calibration is performed by automatically diluting the stock standard solution. In this way, an automatic calibration of each analyte is effectively achieved.
- AN-S-368STREAM – the perfect way of MSM rinsing – even with iron and aluminum in the matrix
The STREAM (suppressor treatment reusing eluent after measurement) is applied since quite some time. The suppressor rinsing with suppressed eluent is advantageous over ultrapure water rinsing: a smaller water dip, faster MSM equilibration, and the avoidance of an additional water supply are just a few. Injecting samples containing iron in the matrix under sulfuric acid regeneration yields reduced peak areas and broader peaks for phosphate. Switching to a regenerant based on sulfuric and oxalic acid allows full regeneration of the MSM. The overlay above shows three subsequently taken chromatograms after more than 300 injections of 10 mg/L iron(II) onto one single MSM chamber. No difference in peak shape or peak area is observed.
- AN-S-383Metrohm IC Driver for OpenLab CDS: Anions with Dose-in Gradient and Dosino Regeneration
OpenLab CDS is the newest generation of chromatography data systems from Agilent. The Metrohm IC Driver 1.0 for OpenLab CDS implements Metrohm ion chromatographs in OpenLab CDS for full control and data acquisition. This application shows the use of a gradient (Dose-in Gradient) as well as Dosino Regeneration in OpenLab CDS. Fluoride, chloride, nitrite, bromide, nitrate, sulfate, phosphate, and iodide in a standard solution are separated and determined.
- AN-S-384Metrohm IC Driver for OpenLab CDS: Iodide measurement with amperometric detection
OpenLab CDS is the newest generation of the Agilent chromatography data systems platform. The Metrohm IC Driver 1.0 for OpenLab CDS enables introducing Metrohm IC instruments to this platform for full control and data acquisition. This application shows the analysis of iodide by amperometric detection, enabling detection at trace levels. The eluent is produced automatically by the 941 Eluent Production Module. In this way, amperometric detection can be executed with the same functionality and performance as with MagIC Net.
- AN-SEC-001Spectroelectrochemistry: an autovalidated analytical technique
Spectroelectrochemical experiments not only provide outstanding qualitative information about samples, but also offer other quantitative data that can be considered when performing analyses. A single set of experiments allows analysts to obtain two calibration curves: one with the electrochemical data and another with the spectroscopic information. The concentration of tested samples is calculated by using both curves, confirming the obtained results by two different routes. In this Application Note, comparison between electrochemical and spectroscopic determinations demonstrates that the two methods measure uric acid (UA) indistinctively, with close agreement of the calculated values with empirical data.
- AN-SEC-002Gathering information from spectroelectrochemical experiments
In-situ spectroelectrochemistry provides dynamic electrochemical and spectroscopic information concurrently with the redox reaction occurring on the electrode surface. Although different spectroelectrochemical configurations can be used, simple equations explain how to relate electrochemistry and spectroscopy for each experimental setup. This Application Note describes how the quantification of one electrochemical parameter (the diffusion coefficient) is calculated from the spectroscopic data as a proof of this concept.
- AN-SEC-003UV-Vis spectroelectrochemical cell for conventional electrodes
The development of a novel reflection cell for conventional electrodes facilitates the performance of spectroelectrochemical measurements. This device allows researchers to work in aqueous solutions as well as in organic media due to its chemical resistance.
- AN-SEC-004Spectroelectrochemical analysis of electrochromic materials
Poly(3,4-ethylenedioxythiophene) (PEDOT) is one of the most promising ICPs due to its high conductivity, electrochemical stability, catalytic properties, high insolubility in almost all common solvents and interesting electrochromic properties (transparent in the doped state and colored in the neutral state). In this Application Note, PEDOT film is evaluated by spectroelectrochemical techniques.
- AN-SEC-005UV/VIS spectroelectrochemical monitoring of 4-nitrophenol degradation
Spectroelectrochemistry is a multi-response technique that provides both electrochemical and spectroscopic information about a chemical system in a single experiment, i.e., it offers information from two different points of view. Spectroelectrochemistry focused on the UV/VIS region is one of the most important combinations because this allows us to obtain not only valuable qualitative information, but also outstanding quantitative results. In this application note, the degradation kinetics for 4-nitrophenol, a known pollutant, were determined using SPELEC.
- AN-SENS-001Quantification of paracetamol with square wave voltammetry
This Application Note demonstrates square wave voltammetry for sensitive, reproducible quantification of paracetamol using a screen-printed electrode and INTELLO.
- AN-SENS-002Detection of heavy metals with differential pulse voltammetry
This Application Note presents DPV as a sensitive, selective method for detecting heavy metals in water, detailing setup, parameters, and advantages over other techniques.
- AN-T-095Automated mixing of a suspension and a solvent using a 50 mL dosing unit
Automated mixing of a suspension and a solvent in a 50 mL dosing unit can be used to add a well-defined amount of a suspension-solvent mixture to a sample solution without clogging the dosing unit and tubing by the undiluted suspension.The method is explained by means of the TAN determination of a petroleum sample using thermometric titration. For a better endpoint recognition, small amounts of a paraformaldehyde-solvent suspension are added (catalyzed endpoint thermometric titration).
- AN-T-104Fully automated determination of barium in aqueous solution
This Application Note describes the fully automated complexometric determination of barium in aqueous solutions with a copper ion-selective electrode.
- AN-T-105Fully automated determination of bismuth(III) in aqueous solution
This application note shows how to determine the bismuth content automatically in aqueous solution with potentiometric titration.
- AN-T-125Automatic determination of cadmium in aqueous solution with the Cu ISE
This application note describes the analysis of cadmium in aqueous solution using a copper ion-selective electrode with Cu-EDTA complex used as an indicator.
- AN-T-126Automatic determination of cobalt in aqueous solution with the Cu ISE
This application note describes the fast, accurate determination of cobalt with a copper ion-selective electrode (Cu ISE) and Cu-EDTA complex as an indicator.
- AN-T-127Automatic determination of copper in aqueous solution with the Cu ISE
This Application Note describes the automated complexometric determination of copper with the Cu ISE.
- AN-T-128Automatic determination of magnesium in aqueous solution with the Cu ISE
Magnesium can be determined with the Cu ISE. A small amount of Cu-EDTA complex is used as an indicator, as the Cu ISE is not selective for magnesium itself.
- AN-T-129Automatic determination of nickel in aqueous solution with the Cu ISE
Nickel can be determined with the Cu ISE. A small amount of Cu-EDTA complex is used as an indicator, as the Cu ISE is not selective for nickel itself.
- AN-T-130Automatic determination of lead in aqueous solution with the Cu ISE
Lead can be analyzed with the Cu ISE. Diammonium tartrate is added to the solution to prevent the precipitation of lead hydroxide in the alkali titration medium.
- AN-T-140Automatic photometric determination of lead using the Optrode
Lead is determined at pH 4 to 5 using back titration with zinc sulfate. Xylenol orange is used as an indicator for visualization of the equivalence point. The equivalence point is detected with the Optrode at a wavelength of 574 mm.
- AN-T-141Automatic photometric determination of manganese using the Optrode
Manganese is determined as Mn(II) in aqueous solutions at pH 10 with Eriochrome Black T as indicator. Ascorbic acid is added to ensure that manganese is present in its bivalent form. The precipitation of water-insoluble manganese hydroxide is prevented by adding triethanolamine (TEA). The Optrode is used for detection at a wavelength of 610 nm.
- AN-T-142Determination of barium using automatic photometric titration
Barium is analyzed in alkali media using direct titration with EDTA. Phthalein purple is used as the indicator; the equivalence point is determined with the Optrode at a wavelength of 574 nm.
- AN-T-143Determination of cobalt using automatic photometric titration
Cobalt is analyzed in aqueous solutions using direct titration with EDTA at a pH value of 9. The indicator is murexide. The equivalence point is determined with the Optrode at a wavelength of 574 nm.
- AN-T-144Mercury analysis using automatic photometric titration
Mercury can be determined in alkali media using back titration with zinc sulfate. Eriochrome black T is used as the indicator for this procedure. The Optrode is used for indication at a wavelength of 502 nm.
- AN-T-145Determination of palladium using automatic photometric titration
Palladium is determined at a pH value of 4 to 5 using back titration with zinc sulfate. Xylenol orange is used as the indicator for visualization of the endpoint. The equivalence point is determined with the Optrode at a wavelength of 610 nm.
- AN-T-146Automatic determination of tin using photometric titration
Tin with EDTA forms very stable complexes in its divalent and tetravalent forms. Hydroxo complexes form in alkali media, which is also why tin is titrated in an acidic medium (pH 2.1). Xylenol orange is used as the indicator. The equivalence point is determined with the Optrode at a wavelength of 574 nm.
- AN-T-147Determination of thallium using automatic photometric titration
Thallium is titrated in slightly acidic medium as Tl(III). Xylenol orange is used as the indicator to determine the endpoint. The equivalence point is determined with the Optrode at a wavelength of 574 nm.
- AN-T-148Determination of zirconium using automatic photometric titration
Zirconium is titrated directly with EDTA in acidic aqueous solution (buffer, pH 1). Eriochrome cyanine R is used as the indicator for this procedure. The equivalence point is determined with the Optrode at a wavelength of 520 nm.
- AN-T-149Determination of thorium using automatic photometric titration
Thorium is titrated with EDTA at a pH value of 4.9. Xylenol orange is used as the indicator for visualization of the equivalence point. The equivalence point is determined with the Optrode at a wavelength of 574 nm.
- AN-T-150Determination of nickel using automatic photometric titration
Nickel analysis can be carried out conveniently in alkali media using photometric titration. Murexide is used as the indicator for visualization of the endpoint. The equivalence point is determined with the Optrode at a wavelength of 574 nm.
- AN-T-153Determination of cadmium using automatic photometric titration
Cadmium can be determined in aqueous solutions using back titration with zinc sulfate. Eriochrome black T is used as the indicator for this procedure. The equivalence point is determined with the Optrode at a wavelength of 610 nm.
- AN-T-158Determination of gallium using automatic photometric titration
Gallium is determined at a pH value of 4.7 using back titration with zinc sulfate. Xylenol orange is used as the indicator for visualization of the equivalence point. The equivalence point is determined with the Optrode at a wavelength of 610 nm.
- AN-T-221SET titration of HPLC mobile phases
This Application Note shows the automatic pH adjustment of a mixture of acetonitrile, water and amine using a Metrohm titrator.
- AN-T-226Determination of functional groups in graphite and graphene oxide
Boehm titration is a quantitative analysis of functional groups on the surface of carbon materials based on their reactions with basic solutions of NaHCO3 (pKa = 6.4), Na2CO3 (pKa = 10.3), and NaOH (pKa = 15.7). This is a cost-efficient method that gives absolute values with high precision of the accessible, mainly oxygen-containing functional groups on the surface. Originally, Boehm titration was developed for carbon materials like conductive carbon black (CCB), activated carbon, porous carbon, and graphite. Modern carbon-based materials like graphene, graphene oxide (GO), or carbon nanotubes can also be analyzed this way.
- AN-T-244Standardization of sodium thiosulfate
The OMNIS Titrator equipped with a Pt Titrode accurately and reliably determines titer concentration even in diluted titrants as shown in this Application Note.
- AN-U-052Transition metal cations applying UV/VIS detection after post-column reaction with PAR (4-(2-pyridylazo)resorcinol)
The Metrosep C 4 columns are mainly used for the separation of alkali and alkaline earth metal cations including ammonium and organic amines. Additionally transition metals may be determined.
- AN-U-061Speciation of iron(II) and iron(III) applying post-column reaction and subsequent UV/VIS detection
Speciation analysis is an important tool in analytical chemistry giving information about the quantitative distribution of different oxidation states of one and the same metal ion. The speciation of iron(II) and iron(III) (Fe 2+/Fe 3+) is achieved by ion chromatographic separation of their anionic dipicolinic acid complexes. Afterwards, post-column reaction with 4-(2-)pyridylazo-resorcinol (PAR) allows VIS detection at 510 nm.
- AN-U-067Trace determination of transition metals with preconcentration (MiPCT), post-column reaction, and UV/VIS detection
The determination of transition metals by ion chromatography is possible with direct conductivity detection (see AN-C-137) as well as with UV/VIS detection after post-column reaction. Here, the cations are separated as anionic complexes and analyzed after post-column reaction with PAR with subsequent UV/VIS detection. Speciation determination of iron (separation of Fe(II) and Fe(III)) is possible with this procedure. For trace analysis, Metrohm Inline Preconcentration Technique (MiPCT) is applied.
- BWT-4907Fundamentals of Raman Spectroscopy
The fundamentals of Raman instrumentation and spectroscopy are presented along with common applications of Raman.
- BWT-4909The Use of Raman Spectroscopy in the Field of Cancer Diagnostics
Raman spectroscopy and surface enhanced Raman spectroscopy (SERS) are proving to be invaluable tools in the field of biomedical research and clinical diagnostics. Raman systems are also being developed for molecular diagnostic testing to detect and measure human cancer biomarkers. This review highlights two applications realting to breast cancer and pancreatic cancer diagnosis together with examples of the use of Raman spectrometry in biomedical research areas such as the identification of bacterial infections, showing that Raman is an important part of the medical toolbox, as we continually strive to improve diagnostic techniques and bring a better health care system to patients.
- WP-002Basics of potentiometry
The present article addresses the theory, practical aspects and troubleshooting of potentiometry.
- WP-003pH measurement: Six technical tips
This white paper presents six technical tips that you should consider before taking a pH measurement.
- WP-009Automated determination of major anions and oxyhalides in drinking water using OMNIS IC and single-standard calibration
This white paper demonstrates how OMNIS IC combines high analytical performance with advanced laboratory automation for drinking water analysis.
- WP-020Near-infrared spectroscopy: Technology comparison
This White Paper compares the two most commonly used technologies in near-infrared spectroscopy: Predispersive monochromator technology and Fourier transformation technology. In addition to measurement speeds and captured spectral ranges, the noise levels and the signal-noise ratios associated with them are also contrasted with one another.
- WP-022In situ SERS effect with screen-printed silver electrodes
In this work, time resolved Raman spectroelectrochemistry measurements with screen printed electrodes are shown. The instrument used combines in a totally integrated box: a 785 nm laser source, a high resolution Raman spectrometer and a bipotentiostat/galvanostat. Experiments are controlled with an excellent spectroelectrochemical software which allows real time data collection and useful data treatment.
- WP-046Overcoming the aqueous limitation at NIR Spectroelectrochemistry
NIR spectroscopy has been traditionally limited due to the water absorption in this spectral range. In this way, the well-known water restriction has limited the development of new applications for NIR spectroelectrochemistry. In this work, several interesting alternatives are proposed in order to minimize or even to remove the aqueous contribution in this spectral range.
- WP-052A Guide to Li-ion Battery Research and Development
The commercialization of Li-ion batteries in 1991 was the culmination of in-depth R&D conducted by scientists and engineers around the globe over the preceding few decades. Further development of Li-ion batteries and alternative rechargeable batteries has continued until today. As the world is rapidly moving towards a new era defined by green technologies, more practical and accurate R&D is required in order to meet the increasing demands for energy storage systems, specifically from the automotive industry. This white paper presents the basics of the Li-ion battery technology and guides the reader through the relevant techniques and terminologies in Li-ion battery research.
- WP-055Corrosion Best Practice – Creating Pipe-flow Conditions Using a Rotating Cylinder Electrode
Electrochemical measurements utilizing a rotating cylinder electrode (RCE) are widely used in industrial corrosion applications when simulation of realistic pipe conditions are necessary in a lab environment. This white paper allows further insight into the particularities and parameters which govern the electrochemical measurements, in particular measurements performed in turbulent flow conditions, and shows a complete picture of the best practice use of this technique. The annexes provide an overview and short explanation of the parameters and laws specific to the fluid behavior in electrochemical cells with RCE.
- WP-058Virus detection: Fast, sensitive, and cost-effective with electrochemical testing
With significant global viral outbreaks becoming the norm rather than generational outliers, it is imperative that fast, sensitive, and cost-effective testing is available to the masses. Screen-printed electrodes (SPEs) allow rapid, widespread testing of populations for infectious disease, without the need of skilled personnel or burdensome equipment in the field. The possibility of point-of-care (POC) testing with SPEs has been exhibited in several recent studies. Metrohm DropSens combines high production capabilites of custom-made SPEs with a valid ISO 13485 certification "Manufacturing of sensors for medical devices", meaning testing procedures developed on these SPEs can be reliably scaled up for larger operations, with easier regulatory approval for commercialization.
- WP-062Overcoming difficulties in ion measurement: Tips for standard addition and direct measurement
Ion measurement can be conducted in several different ways, e.g., ion chromatography (IC), inductively coupled plasma optical emission spectrometry (ICP-OES), or atom absorption spectroscopy (AAS). Each of these are well-established, widely used methods in analytical laboratories. However, the initial costs are relatively high. In contrast, ion measurement by the use of an ion-selective electrode (ISE) is a promising alternative to these costly techniques. This White Paper explains the challenges which may be encountered when applying standard addition or direct measurement, and how to overcome them in order for analysts to gain more confidence with this type of analysis.
- WP-066An introduction to ion chromatography mass spectrometry (IC-MS)
Ion chromatography mass spectrometry (IC-MS) is a powerful tool that can handle many challenging analytical tasks which cannot be performed adequately by IC alone. IC-MS is a robust, sensitive, and selective technique used for the determination of polar contaminants like inorganic anions, organic acids, haloacetic acids, oxyhalides, or alkali and alkaline earth metals. After separation of the sample components via IC, mass selective detection guarantees peak identity with low detection limits. The inclusion of automated Metrohm Inline Sample Preparation (MISP) allows not only water samples, but also chemicals, organic solvents, or post-explosion residues to be readily analyzed without need for extensive manual laboratory work. This White Paper explains the benefits of IC-MS over IC in certain cases, the hyphenation of IC and different MS systems, as well as related norms and standards.
- WP-069(Un)Grounded: Grounded and floating measurements and their application in electrochemical research
In this White Paper, details of the electronic (PGSTAT) and electrochemical cell grounding are presented together with the necessity of using a floating PGSTAT for different application and experimental examples. Due to the wide variation of experimental requirements and kinds of electrochemical cells, the use of an electrochemical instrument with a selectable floating feature (such as VIONIC) which brings additional versatility to the user is recommended.
- WP-073On-site detection of hexavalent chromium in protective paint primers
It is widely accepted that prolonged exposure to hexavalent chromium compounds can have dire health effects. This has led to increased regulation of chromium-containing products and greater demand for technologies that can positively identify hexavalent chromium in potential matrices. These include paints, dyes, and primers, which can pose a problem for interrogation with Raman, as strongly colored materials often exhibit fluorescence when stimulated at 785 nm. Fluorescence can obscure the Raman signal and prevent positive identification. MIRA XTR DS provides all the functionality of handheld material ID with a new capability that selectively eXTRacts the Raman signal from fluorescent materials. Fluorescence rejection at 785 nm provides higher sensitivity and resolution than 1064 nm systems, as well as a much wider scope of applications amenable to Raman spectroscopy. MIRA XTR DS offers a comprehensive and versatile material ID test solution for field operations.
- WP-079How to characterize a catalyst? Cyclic voltammetry in action
This White Paper introduces the principles of cyclic voltammetry (CV) and the various ways it can be used for catalyst investigation. A case study and helpful glossary are provided to support your understanding.
- WP-080Seamless electrochemical measurements with VIONIC powered by INTELLO
This White Paper introduces seamless measurements that are possible with VIONIC powered by INTELLO and applications that can benefit from this unique feature. The combination of software and new generation electronics provides data in real-time with no gaps or missed reactions.
- WP-083Hyphenated electrochemical-Raman spectroscopy: Another dimension for your research
White paper about Raman spectroscopy and electrochemistry and their combination (electrochemical Raman).
- WP-086Measuring organic acids and inorganic anions with ion chromatography mass spectrometry
This White Paper focuses on selected IC-MS applications for the straightforward identification and quantification of organic acids and inorganic anions in different matrices.
- WP-087Green alternative methods for voltammetric analysis in different water matrices
This White Paper presents four different «green» sensors: the scTRACE Gold, screen-printed electrodes, the glassy carbon electrode, and the Bi drop electrode from Metrohm that can be used to determine low concentrations of heavy metals in different sample matrices, such as boiler feed water, drinking water, and sea water.
- WP-091Case study: Ion chromatography in pharmaceutical research and development
This White Paper will walk you through the selection process of ion chromatography as the best analytical tool in the product development of a cell-based gene therapy.
- WP-095The future of manufacturing and commercializing green ammonia with electrochemistry
Free White Paper outlines the fundamental principles of the nitrogen reduction reaction. It then delves into the technical barriers hindering the industrialization of green ammonia production, their impact on final yield and selectivity, and potential strategies or research gaps to overcome these issues.
- WP-097Why switch to OMNIS Client/Server (C/S)?
OMNIS Client/Server boosts business performance with scalable server management, cutting costs by reducing hardware, energy use, and maintenance across locations.