Applications
- 8.000.6043Automated dialysis as a sample preparation tool in ion chromatography
The analytical challenge treated in the present work consists in the determination of chloride, phosphate and sulfate in the presence of difficult sample matrices that interact with the stationary column phase or even render it unusable. Metrohm`s patented stopped-flow dialysis coupled to the new 881 Compact IC pro ion chromatograph overcomes these drawbacks. Two standard solutions covering the concentration ranges 1.0…3.6 mg/L and 10…36 mg/L as well as two samples, an ultra-high temperature (UHT) processed milk and a baby milk powder, were characterized in terms of analyte concentration, relative standard deviation, calibration quality, carryover and recovery rates. While the five-point calibration curves yielded correlation coefficients (R) better than 0.9999, carryover (between two subsequent injections of a concentrated sample and a blank) was less than 0.49%. Recoveries for the low (10…36 mg/L) and high standard concentrations (1.0…3.6 mg/L) were within 91…99% and 94…100%, respectively. Automated compact stopped-flow dialysis is a leading-edge sample preparation technique that ensures optimum separation performance by effectively protecting the column from detrimental matrix compounds.
- AB-053Determination of ammonium or Kjeldahl nitrogen
The potentiometric titration of Kjeldahl nitrogen is one of the most common analytic procedures. It is referenced in numerous standards, ranging from the food and animal feed industries through sewage and waste analysis and all the way to the fertilizer industry. As a rule, the samples are digested with concentrated sulfuric acid with the addition of a catalyst. The ammonium sulfate that is formed is distilled as ammonia in alkali solution, collected in an absorption solution and titrated there.This Bulletin provides a detailed description of potentiometric nitrogen determination following distillation of the digestion solution, followed by a discussion of the possibilities of coulometric titration (without distillation).
- AB-083Sodium analysis by ion-selective electrode
This document explains how to measure Na ion concentration in diverse matrices with a sodium ion-selective electrode (Na-ISE) using direct measurement and standard addition.
- AB-086Measuring the pH value of dairy products
This Bulletin describes methods for measuring the pH value of dairy products. Particular attention has been paid to the handling, maintenance, and storage of the pH electrodes.
- AB-087Analysis of dairy products
This Bulletin describes potentiometric titration methods for the determination of the acidity in milk and yoghurt according to DIN 10316, ISO/TS 11869, IDF/RM 150, ISO 6091 and IDF 86, the chloride content in milk, butter and cheese according to EN ISO 5943, IDF 88, ISO 15648, IDF 179, ISO 21422, and IDF 242. Additionally the determination of the sodium content in milk using the thermometric titration is described. The determination of the oxidation stability of butter in accordance to AOCS Cd 12b-92, ISO 6886 and GB/T 21121 as well as the determination of lactose in lactose free milk by ion chromatography is also described.For the determination of the pH value in dairy products see Application Bulletin AB-086 and for the determination of calcium and magnesium see Application Bulletin AB-235.
- AB-098Determination of ascorbic acid (Vitamin C) and its compounds
In addition to its natural occurrence in fruit and vegetables, ascorbic acid (Vitamin C) is used as an antioxidant in foods and drinks. Ascorbic acid is furthermore also to be found in numerous drugs.Ascorbic acid and its salts and esters can be determined with titration or by using polarography, for which ascorbic acid is oxidized to form dehydroascorbic acid.Bi-voltammetric or photometric equivalence point indication can be used for titrimetric determination. It must be taken into account here that only bi-voltammetric indication is independent of the inherent color of the sample. Polarography is the most selective of the methods described, as other reducing or oxidizing substances are not recorded.
- AB-130Chloride titrations with potentiometric indication
Potentiometric titration is an accurate method for determining chloride content. For detailed instructions and troubleshooting tips, download our Application Bulletin.
- AB-137Coulometric water content determination according to Karl Fischer
This Application Bulletin gives an overview of the coulometric water content determination according to Karl Fischer.Amongst others, it describes the handling of electrodes, samples, and water standards. The described procedures and parameters comply with the ASTM E1064.
- AB-191Determination of cysteine and cystine simultaneously by polarography
After the degradation of biological samples (e.g. milk, wool, etc.), it is often important to know the cystine/cysteine ratio. This Application Bulletin describes the simultaneous, polarographic determination of the two amino acids. The determination is performed in perchloric acid solution at the DME. Samples with a high protein content require that the determination is performed in an alkaline solution.
- AB-235Potentiometric titration of calcium (magnesium) in dairy products
This Bulletin describes a simple method for the determination of the calcium content in dairy products. The use of CuEGTA and the ion-selective copper electrode (Cu ISE) as indicator electrode allows the determination to be performed without time-consuming sample preparation. If the complexing agent EDTA is used as titrant instead of EGTA, the sum of calcium and magnesium is obtained. The magnesium content can then be calculated from the difference between the results of the two titrations.
- AB-280Automatic Karl Fischer water content determination with the 874 Oven Sample Processor
Generally speaking, the gas extraction or oven method can be used for all samples which release their water when they are heated up. The oven method is indispensable in cases in which the direct volumetric or coulometric Karl Fischer titration is not possible, either because the sample contains disruptive components or because the consistency of the sample makes it very difficult or even impossible to transfer it into the titration vessel.The present Application Bulletin describes automatic water content determination with the aid of the oven technique and coulometric KF titration, using samples from the food, plastic, pharmaceutical and petrochemical industry.
- AB-342Automated determination of calcium and magnesium in milk with thermometric titration
This bulletin deals with the automated determination of calcium and magnesium in commercially available finished milk products using a 859 Titrotherm and a 814 USB Sample Processor. Calcium and magnesium in milk can be rapidly and easily titrated thermometrically using a standard solution of Na4EDTA as titrant.Thermometric titrations are conducted under conditions of constant titrant addition rate. The molarity of the titrant is computed automatically in tiamo (software) using the SLO command. Results are reported as mg Ca and Mg/100 mL.
- AB-343Automated determination of sodium in milk with thermometric titration
This bulletin discusses automated determination of sodium in milk products available to the public using a 859 Titrotherm and a 814 USB Sample Processor. The sodium content of milk can be rapidly and easily titrated thermometrically with a standard solution of Al3+ as titrant. Thermometric titrations are conducted under conditions of constant titrant addition rate. The molarity of the titrant is computed automatically in tiamoTM (software) with the SLO command. Results are reported as mg Na/100 mL. In addition to this application bulletin, you can find more information on thermometric sodium determination in foods in our application video available on YouTube:https://youtu.be/lnCp9jBxoEs
- AB-408Oxidation stability of fats and oils in solid foods using the Rancimat method
The Rancimat method determines the oxidation stability (OSI) and antioxidant capacity (SI) of solid foods. OSI measurements are performed directly, with extracted isolated fat, or via the polyethylene glycol method. SI can be determined when the sample is mixed with a reference of antioxidant-free fat.
- AN-C-028Four cations in an instant baby milk powder using dialysis for sample preparation
Determination of sodium, potassium, calcium, and magnesium in instant baby milk powder using cation chromatography with direct conductivity detection and dialysis for sample preparation.
- AN-C-100Choline in infant milk powder using online dialysis
Determination of choline in infant milk powder using cation chromatography with direct conductivity detection applying Metrohm Inline Dialysis.
- AN-C-179Cations and lactic acid in whey powder applying two separation mechanisms in the same analysis
Whey is the remaining liquid after cheese production. It is mainly used as feed. It is also used as dietary supplement as a beverage or in powder form. This application determines lactic acid as well as cations in one determination. The Metrosep C 6 - 250/4.0 column separates sodium, potassium, magnesium, and calcium by ion exchange. It also acts as an ion-exclusion column, which separates lactic acid. Both lactic acid and the cations can be determined in the same run applying direct conductivity detection. While cations typically elute as negative peaks, lactic acid elutes as an early positive peak. MagIC Net shows both in the usual positive direction.
- AN-CS-004Determination of choline in baby milk powder
Choline is important for the biosynthesis of numerous molecules, e.g., the neurotransmitter acetylcholine, and exists as an intermediate product in the human metabolism. Concentration determination takes place after microwave digestion. Separation is performed on the Metrosep C Supp 1 - 250/4.0 column following sequential suppression. Separation from the standard cations is outstanding.
- AN-H-103Determination of Calcium and Magnesium in Milk
A measured amount of milk is treated with trichloroacetic acid to coagulate milk solids and liberate calcium and magnesium as dissociated ion. The coagulated milk is filtered or centrifuged, and an aliquot of the clear serum is titrated with a standard solution of 1 mol/L tetra-sodium EDTA to thermometrically determined endpoints for Ca and Mg. Acetylacetone is added to alter the Ca- and Mg- EDTA stability constants for better endpoint sharpness.
- AN-H-133Automatic sodium determination in cheese
Sodium can be determined thermometrically in cheese without sample preparation and addition of additives. A homogenizer is responsible for distribution and stirring. In addition to this application note, you can find more information on thermometric sodium determination in foods in our application video available on YouTube:https://youtu.be/lnCp9jBxoEs
- AN-I-032Dissolved oxygen, conductivity, and pH value in liquid dairy products
In the food industry, it is essential to determine and monitor certain quality parameters to guarantee consistency. This is especially important for liquid dairy products, which are subject to a strict cold chain. Both the dissolved oxygen (DO) and the pH value have proven to be reliable quality criteria. Oxygen shortens the shelf life and influences the product quality (e.g., nutritional value, color, and flavor). The DO content depends on the salinity in the sample, which is automatically calculated and corrected by the 914 pH/DO/Conductometer during the parallel conductivity measurement. Acidity is another important characteristic to measure that can be checked easily using the pH value. With the 914 pH/DO/Conductometer, all important quality criteria can be monitored with one device.
- AN-K-007Water in yoghurt powder
The water content of yoghurt powder is determined according to Karl Fischer. Because of the relatively high water and fat content, the sample is prediluted with a 1:1 mixture of chloroform and methanol.
- AN-NIR-128Milk powder analysis by near-infrared spectroscopy
Near-infrared spectroscopy saves time and resources by simultaneously measuring key quality parameters like lactose, moisture, fat, and protein content in milk powder.
- AN-NIR-139Quality control of ice cream mix with near-infrared spectroscopy
NIR spectroscopy measures ice cream quality parameters like total solids, fat content, lactose, protein percentage, sucrose content, and calories in seconds.
- AN-NIR-144Whey permeate analysis with NIRS
NIRS simultaneously measures important quality parameters in whey permeate (i.e., ash, phosphate, lactose, protein, pH, and moisture) without any sample preparation.
- AN-P-055Lactose residues in "lactose-free" milk
Lactose intolerance means that lactose cannot be digested. Lactose is contained in milk and milk products. "Lactose-free milk" is analyzed following Inline Dialysis. No lactose was detected in the milk sample investigated. The chromatogram of the spiked sample corresponds to the limit value of 100 mg/L that applies for lactose-free milk. The separation is performed on the Metrosep Carb 2 - 150/4.0 column.
- AN-P-071IC-amperometric sugar analysis in fruit yogurt pursuant to EU regulation 1169/2011
EU Regulation 1169/2011 defines rules for nutrition declaration on foodstuffs. The objective is to provide food information to the general public and to label food ingredients that are hazardous to health when consumed in larger quantities. This Application Note describes the determination of fruit yogurt with the aid of the Metrosep Carb 2 - 150/2.0 column.
- AN-P-085Iodine monitoring in natural sources
Iodine is an essential mineral for human health, where it is necessary for e.g., the production of thyroid hormones. The presented method describes the determination of free iodide in milk samples using Metrohm Low Volume Inline Dialysis for automated sample preparation prior to injection into an ion chromatograph (IC) and subsequent amperometric detection in direct current (DC) mode.
- AN-P-088Quality testing for infant formula
This Application Note presents ion chromatography with pulsed amperometric detection as fast and reliable method to determine low level lactose in complex matrices such as infant formula.
- AN-P-089Lactose intolerance and reliance on accurate food labels
Worldwide, milk and dairy products are vital sources for human nutrition. A major component and energy source in dairy products is lactose. To efficiently metabolize lactose, the enzyme lactase is indispensable. However, globally nearly 70% of the population is lactose intolerant and they have difficulties to digest lactose. Lactose malabsorption leads to numerous gastrointestinal and extra-intestinal symptoms and other complaints with varying extents. Therefore, consumers rely on accurate food labels and for manufacturers appropriate sensitive analytical techniques are a must to comply with these demands. Ion chromatography with pulsed amperometric detection (IC-PAD) enables the determination of very low lactose contents. Validation according to AOAC requirements shows the high sensitivity and reliability of this method as a routine analysis.
- AN-RS-015Trace Detection of Melamine in Dairy Products
In 2008, a scandal was discovered in China that melamine was being deliberately added to raw milk. Thousands of young children and infants that consumed formula produced from melamine-tainted milk experienced kidney damage and death. As a result, both daily intake limits and increased monitoring of melamine in dairy products were established globally.Misa (Metrohm Instant SERS Analyzer) provides quick, easy, and robust detection of melamine in a complex food matrix. As a direct test with no additional reagents, Misa’s assay format requires minimal user training, in contrast to standard analytical tests for detecting melamine, including capillary electrophoresis, GC-MS, LC-MS, and immune-based assays.
- AN-S-162Iodide in milk powder
Determination of iodide in milk powder using anion chromatography with conductivity detection after chemical suppression and inline sample preparation by dialysis.
- AN-S-297Iodide, thiocyanate, and perchlorate in milk applying Inline Dialysis
Anion analysis in milk requires a sophisticated sample preparation to avoid column fouling by fats or proteins. Here Metrohm Inline Dialysis is the perfect automated technique. In dairy products iodide, thiocyanate, and perchlorate need to be determined regularly for health and hygiene reasons. This application allows for the first time to analyze these three components in this matrix within one run.
- AN-T-066Calcium in cheese
Determination of calcium in cheese by potentiometric titration with EGTA using the Cu-ISE.
- AN-T-106Fully automated determination of calcium in milk
In this Application Note, the determination of calcium in milk is shown with the copper ion-selective electrode which is less sensitive to contamination from proteins.
- AN-T-132Titratable acidity in milk and yogurt
The titratable acidity gives an indication of the freshness of milk and yogurt as well as other fermented milk products. The determined titratable acidity in milk is mainly given through the absorption of hydroxyl ions by milk proteins and milk salts. The acidity increases with bacterial acidification and with enzymatic lipolysis. The titratable acidity corresponds to the amount of sodium hydroxide required to titrate 100 g sample to a pH value of 8.30.In this Application Note, an easy and accurate method to determine the titratable acidity in milk according to DIN 10316 and in yogurt according to ISO/TS 11869 and IDF/RM 150 is demonstrated.
- AN-T-133Chloride in milk and milk powder
In order to maintain product quality, the sodium chloride content in dairy products must be monitored and not exceed the limits defined by the respective public health authorities. The chloride content in food correlates with the salt content, its determination is therefore described in various norms and standards. However, preparation of such samples is time consuming, as it includes a chloride extraction with warm water. Whole milk powders in particular are difficult to handle as an inhomogeneous dispersion of fat in the titration suspension occurs.In order to reduce the workload, increase sample throughput, and eliminate the matrix challenges posed by high fat products, this Application Note presents a fully automatic potentiometric titration of chloride with silver nitrate in milk and milk powder based on ISO 21422, IDF 242, AOAC 2015.07, AOAC 2015.08 and AOAC 2016.03
- AN-T-134Chloride in salted butter – Automated standard method reduces saves time and helps increase throughput
The salt content in food is a critical parameter, given that the WHO recommends a maximum daily intake of 5 g for an adult. In butter with a salt content exceeding 0.1%, it can be determined by a precipitation titration of chloride with silver nitrate. However, during manual titration the operator cannot leave the system unattended because he has to exchange the sample beakers manually which is time consuming and prone to errors.This Application Note describes the automated determination of chloride in salted butter in accordance with ISO 15648, ISO 21422, IDF 179 and IDF 242. If automated according to the norms and standards, salt determination can be performed completely unattended with superior reproducibility of results increasing efficiency in the laboratory.
- AN-T-135Chloride in cheese – Automation reduces sample preparation and increases throughput
The WHO recommends a maximum daily intake of 5 g salt for an adult. The chloride content in food correlates with the salt content, its determination is therefore described by various standards. In cheese and cheese products with a chloride content higher than 0.2%, chloride is usually determined by a precipitation titration with silver nitrate. However, time-consuming sample preparation is required, as the cheese has to be homogenized and the chloride extracted with hot water.This Application Note describes the fully automatic determination of chloride in cheese according to EN ISO 5943, ISO 21422, IDF 242 and IDF 88 including sample preparation with a Polytron homogenizer. This increases productivity due to a higher sample throughput and lower work load for the operator.
- AN-T-171Redox titration of vitamin C in milk powder using the double Au-ring electrode
Vitamin C is an important antioxidant included in milk powder. The double Auring electrode provides an excellent titration curve when using 2,6-dichlorophenolindophenol (DPIP) as titrant and is easy to clean.With the OMNIS system, a fast and accurate determination of vitamin C in milk powder by a bi-voltametric titration is realized.
- AN-U-042Melamine in food using cation chromatography with UV/VIS detection
Determination of melamine in milk, diary products, eggs, and egg-based foodstuffs using cation chromatography.
- AN-V-060Cysteine and cystine in caseinate
Determination of cysteine and cystine in caseinate after sample preparation with NaOH.
- EB-003Ion chromatography for food and beverage analysis
Efficiently analyze food products with ion chromatography (IC). Discover its robust applications in quality control for beverages, food additives, and dairy.
- WP-050Manual titration vs. automatic titration: benefits and advantages to switching
This white paper summarizes the advantages and benefits of automated titration in comparison to manual titration. The increase in accuracy and precision of measurements as well as significant time and cost savings are discussed.
- WP-077Robust multiparameter analysis of infant and follow-on formulas with ion chromatography (IC)
Free white paper gives comprehensive overview of how to reliably assess the quality of infant formula with ion chromatography.
- WP-088Simplified analysis of dairy products with Metrohm Inline Dialysis
This White Paper compares automated Inline Ultrafiltration and Inline Dialysis to the traditional Carrez clarification procedure for the analysis of milk samples by ion chromatography (IC). A continuous test series over approximately six months proved Inline Dialysis to be a reliable and valuable alternative to treat dairy products prior to IC analysis.
- WP-097Why switch to OMNIS Client/Server (C/S)?
OMNIS Client/Server boosts business performance with scalable server management, cutting costs by reducing hardware, energy use, and maintenance across locations.