Search
6.0730.100
Complete LL-Ag/AgCl(gel) reference electrodeMaintenance-free Double-Junction Ag/AgCl reference electrode for voltammetry. Made of glass with electrolyte c(KCl) = 3 mol/L (gel), for pH 0 - 8. Suitable for use in continuous operation in automated systems and online instruments.
6.0726.110
Ag/AgCl reference electrode (length 16.2 cm)Silver / silver chloride reference electrode with double junction system, installation length 13.8 cm. This reference electrode is well suited for automated applications. The SGJ 14/15 enables easy assembly and the flexible ground-joint diaphragm, which is insensitive to contamination, can be easily replaced. The reference and bridge electrolyte can be freely selected according to the application and are easy to exchange. This sensor is delivered without electrolyte filling.
6.0729.100
Ag/AgCl reference electrode (length 12.5 cm)Silver/silver chloride reference electrode with Double-Junction System and separate shielding, installation length 10 cm.This reference electrode is well-suited for:Nonaqueous samples; Differential potentiometry; The standard ground-joint 14/15 enables easy assembly, and the flexible ground-joint diaphragm, which is insensitive to contamination, can be replaced at any time. The reference electrolyte and the bridge electrolyte can be selected freely according to use, and are easy to replace. The sensor is supplied without electrolyte filling.
6.0729.110
Ag/AgCl reference electrode (length 16.2 cm)Silver/silver chloride reference electrode with Double-Junction System and separate shielding, installation length 13.8 cm.This reference electrode is well-suited for:Automated applications; Nonaqueous samples; Differential potentiometry; The standard ground-joint 14/15 enables easy assembly, and the flexible ground-joint diaphragm, which is insensitive to contamination, can be replaced at any time. The reference electrolyte and the bridge electrolyte can be selected freely according to use, and are easy to replace. The sensor is supplied without electrolyte filling.
6.0726.100
Ag/AgCl reference electrode (length 12.5 cm)Silver/silver chloride reference electrode with Double-Junction System, installation length 10 cm.The standard ground-joint 14/15 enables easy assembly, and the flexible ground-joint diaphragm, which is insensitive to contamination, can be replaced at any time. The reference electrolyte and the bridge electrolyte can be selected freely according to use, and are easy to replace. This sensor is supplied without electrolyte filling.
6.0726.107
Ag/AgCl reference electrode with KCl (length 12.5 cm)Silver / silver chloride reference electrode with double junction system, installation length 10 cm.The SGJ 14/15 enables easy assembly and the flexible ground-joint diaphragm, which is insensitive to contamination, can be easily replaced. The reference and bridge electrolyte can be freely selected according to the application and are easy to exchange. This sensor is pre-filled with c(KCl) = 3 mol/L as reference and bridge electrolyte.