913 pH Meter with accessories case

913 pH Meter with accessories case
Order number: 2.913.0110

Portable two-channel pH measuring instrument for measuring pH/mV and temperature. You will be optimally equipped for measurements outdoors with this battery-operated measuring instrument.
 

  • Portable pH meter with built-in battery pack and two galvanically isolated pH measuring inputs.
  • Analog pH measuring input for Metrohm standard pH electrodes
  • Digital pH measuring input for the intelligent pH electrodes from Metrohm
  • Robust, water-tight and dust-tight housing (IP67) for hard outdoor and laboratory use
  • LCD color display with background illumination for simple legibility of the results
  • USB interface for simple data export to PC or printer
  • Large internal memory (10,000 data sets)
  • Pin-protected User and Expert modes, prevents unwanted parameter changes
  • GLP-compliant printout and data export with User ID and timestamp
  • Robust field case for routine measurements in the field

 

  • Tech specs
  • Documents
  • Included parts
  • Opt. equipment
Dimensions (W/H/D) 208 mm / 92 mm / 34 mm
Display 3.5" color display
Good Laboratory Practice (GLP) Yes, data with User ID, timestamp, electrode ID
Measuring inputs 2
Measuring mode 1 x pH/U/T analog
1 x pH/U/T digital
Memory size 10,000 measured values
mV accuracy ±0.2 mV
mV range -1,200.0 mV - +1,200.0 mV
mV resolution 0.1 mV
pH accuracy ±0.003 pH
pH calibration points 1 - 5
pH range -13,000 - +20,000
pH resolution 0.001 pH
Power supply Lithium-polymer rechargeable battery 3.7 V; 3,000 mAh
Protection class IP67
Weight 400 g
  • Brochure: 912 Conductometer, 913 pH Meter, 914 pH/Conductometer – The new generation of Metrohm meters for pH and conductivity measurement (english)
    • 中文产品手册:912 Conductometer、913 pH Meter、914 pH/Conductometer-新一代万通 pH 值及电导测量仪 (中文)
    • Prospectus : 912 Conductometer, 913 pH Meter, 914 pH/Conductometer – La nouvelle génération d'instruments de mesure du pH et de la conductivité de Metrohm (français)
    • Prospekt: 912 Conductometer, 913 pH Meter, 914 pH/Conductometer – Die neue Generation von Metrohm Metern für die pH- und Leitfähigkeitsmessung (deutsch)
    • Brochure: 912 Conductometer, 913 pH Meter, 914 pH/Conductometer – The new generation of Metrohm meters for pH and conductivity measurement (日本語)
  • Declaration of conformity for 913 pH Meter (english)
  • Leaflet Accu Management 91x Meter
  • Manual for 912/913/914 pH Meter/Conductometer (english)
    • 912/913/914 pH Meter/Conductometer 手册 (中文)
    • Mode d'emploi du 912/913/914 pH Meter/Conductometer (français)
    • Handbuch 912/913/914 pH Meter/Conductometer (deutsch)
    • Manual de pH-metro/conductímetro 912/913/914 (español)
  • Release Notes 91x pH-Conductometer 5.91x.0014 (english)
    • Release Notes 91x pH-Conductometer 5.91x.0014 (deutsch)
  • Release Notes for 912 Conductometer | 913 pH Meter | 914 pH/Conductometer - 591xx012 (english)
    • Release Notes 912 Conductometer | 913 pH Meter | 914 pH/Conductometer - 591xx012 (deutsch)
  • Release Notes for 912 Conductometer | 913 pH Meter | 914 pH/Conductometer - 591xx013 (english)

Download the complete Scope of Delivery and Optional Accessories for as PDF:

  • Primatrode with NTC (IP67, fixed cable 1.2 m)
    6.0228.020
    Primatrode with NTC (IP67, fixed cable 1.2 m)

    Combined pH electrode with integrated temperature sensor (NTC) and fixed cable conforming to IP67 (1.2 m).
    This electrode is suitable for an introduction to GLP-compliant pH measurements in solutions that do not contain precipitates, proteins, or sulfides. This electrode is mechanically resistant thanks to the robust/unbreakable plastic shaft made of polypropylene and impact protection for the glass membrane.
    Additionally, this electrode offers a waterproof plug for mobile use with Metrohm pH meters.
    Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.

    1 piece(s)

  • SGJ stopper / B-14/(15)
    6.1446.000
    SGJ stopper / B-14/(15)

    2 piece(s)

  • Bottle / 25 mL
    6.1613.010
    Bottle / 25 mL

    2 piece(s)

  • Bottle / 25 mL / label pH 7 (empty)
    6.1613.020
    Bottle / 25 mL / label pH 7 (empty)

    1 piece(s)

  • Bottle / 25 mL / label pH 4 (empty)
    6.1613.030
    Bottle / 25 mL / label pH 4 (empty)

    1 piece(s)

  • Wash bottle / 250 mL
    6.1614.000
    Wash bottle / 250 mL

    1 piece(s)

  • Holder for electrode storage vessel
    6.2008.060
    Holder for electrode storage vessel

    Practical holder for fastening the electrode storage vessels to the 912, 913 or 914 pH/Conductometers.

    1 piece(s)

  • Carrying strap for 912/913/914
    6.2050.010
    Carrying strap for 912/913/914

    Carrying strap for 912/913/914 meters

    1 piece(s)

  • Adapter USB MINI (OTG) - USB A
    6.2151.100
    Adapter USB MINI (OTG) - USB A
    For connecting USB instruments.

    1 piece(s)

  • Cable USB MINI (OTG) - USB A, 1.8 m
    6.2151.110
    Cable USB MINI (OTG) - USB A, 1.8 m
    For connecting USB instruments.

    1 piece(s)

  • USB power supply unit 5.25 V / 1.53 A
    6.2166.100
    USB power supply unit 5.25 V / 1.53 A

    USB power supply unit for 912 / 913 / 914

    Efficiency Level VI

    1 piece(s)

  • Buffer solutions pH 4, 7 and 9
    6.2307.230
    Buffer solutions pH 4, 7 and 9
    Mixed buffer solutions pH 4.00/7.00/9.00 (25 °C) in single use sachets, colourless, box of 3 x 10 x 30 mL

    1 piece(s)

  • Electrolyte  3 mol/L KCl (50 mL)
    6.2308.050
    Electrolyte 3 mol/L KCl (50 mL)
    Electrolyte solution c(KCl) = 3 mol/L (for Ag/AgCl reference systems)

    1 piece(s)

  • Case for 912 / 913 / 914
    6.2716.060
    Case for 912 / 913 / 914

    Case for the 912 / 913 / 914 pH/Conductometers.

    1 piece(s)

  • PP beaker, 100 mL
    6.2717.000
    PP beaker, 100 mL

    Beaker made of PP, 100 mL.

    1 piece(s)

Download the complete Scope of Delivery and Optional Accessories for as PDF:

  • USB thermal printer Neo's
    2.141.0100
    USB thermal printer Neo's

    Compact printer with USB interface for the Ti-Touch, the Titrino plus and Dosimat plus and the 91X Meter instruments.

    Paper width 60 mm (40 characters). Including 6.2151.120 USB cable.

  • EPSON TM U220B impact printer
    2.143.0100
    EPSON TM U220B impact printer

    Impact printer with USB interface for the 912/913/914 hand meter.

    Power supply units: 100 - 240 V
    Paper width: 76 mm

     

  • 854 iConnect
    2.854.0010
    854 iConnect

    854 iConnect - electrode cable and measuring amplifier for intelligent electrodes «iTrodes».

  • Stand plate for 912/913/914
    6.2001.130
    Stand plate for 912/913/914

    Stand plate for converting a mobile 912/913/914 pH/Conductometer into a laboratory meter.

  • Y cable USB A St - USB B St - Mini B St
    6.2151.140
    Y cable USB A St - USB B St - Mini B St

    Y cable for connection of a USB printer to the pH/Conductometers 912 / 913 / 914. This cable allows a printer and the power supply unit to be connected to the measuring instrument at the same time.

  • 12 V USB adapter for 912 / 913 / 914 pH/Conductometer
    6.2166.500
    12 V USB adapter for 912 / 913 / 914 pH/Conductometer

    12 V USB adapter for 912 / 913 / 914 pH/Conductometer.

  • pHit kit
    6.2325.000
    pHit kit

    Maintenance kit for pH electrodes

    The kit contains:

    • 50 mL cleaning solution
    • 50 mL 3M KCl solution
    • 50 mL storage solution
    • 2 Storage vessels
    • Instructions for use
  • tiBase 1.1 full (1 license)
    6.6063.112
    tiBase 1.1 full (1 license)

    PC program for managing titration data.


    The following instruments are supported:

    • 899 Coulometer
    • 848 Titrino plus
    • 862 Compact Titrosampler
    • 870 Titrino plus
    • 877 Titrino plus
    • 840 Touch Control (Titrando)
    • 900 Touch Control (Titrando)
    • 912 Conductometer
    • 913 pH Meter
    • 914 pH/Conductometer
    • 915 KF Ti-Touch
    • 916 Ti-Touch
    • 917 Coulometer