Coulometric KF equipment, including generator electrode with diaphragm

Coulometric KF equipment, including generator electrode with diaphragm
Order number: 6.5406.000

Complete accessory set for KF coulometer.


  • Included parts

Download the complete Scope of Delivery and Optional Accessories for as PDF:

  • Double Pt-wire electrode for coulometry
    6.0341.100
    Double Pt-wire electrode for coulometry

    Indicator electrode used for coulometric Karl Fischer titration.

    1 piece(s)

  • Generator electrode with diaphragm
    6.0344.100
    Generator electrode with diaphragm

    Generator electrode with diaphragm for coulometric Karl Fischer titrations, SGJ 29/22.
    This generator electrode is well suited for:
     

    • samples with very low absolute water contents < 50 ppm
    • coulometric water content determination in oil samples
    • applications where ketone reagents are used
    • applications where low-conducting reagents are used (addition of chloroform, xylene >10%)

    1 piece(s)

  • KF adsorber tube for coulometer cell
    6.1403.030
    KF adsorber tube for coulometer cell

    For KF coulometers.


    1 piece(s)

  • SGJ stopper SGJ 14
    6.1437.000
    SGJ stopper SGJ 14

    1 piece(s)

  • Stopper / B-14/15 / M10
    6.1446.060
    Stopper / B-14/15 / M10

    1 piece(s)

  • Septum 16 mm, 5 pieces
    6.1448.020
    Septum 16 mm, 5 pieces
    Set of 5 pcs.

    2 piece(s)

  • KF titration vessel / 80-250 mL / coulometric
    6.1464.320
    KF titration vessel / 80-250 mL / coulometric

    1 piece(s)

  • Stirring bar / 25 mm
    6.1903.030
    Stirring bar / 25 mm

    Stirring bar with magnetic core, PTFE covering, length 25 mm.


    1 piece(s)

  • Titration vessel holder
    6.2047.020
    Titration vessel holder
    Titration vessel holder for coulometric cells.Used with 756, 831 KF Coulometer

    1 piece(s)

  • Electrode cable / 1 m / F
    6.2104.020
    Electrode cable / 1 m / F
    For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).

    1 piece(s)

  • Electrode cable / 1 m / H
    6.2104.120
    Electrode cable / 1 m / H
    With plug H. For connecting generator electrode - KF Coulometer.

    1 piece(s)

  • 
    GL 18 screw cap with hole
    6.2701.040
    GL 18 screw cap with hole
    Made of PBT. With a hole for the 6.1448.020 septum. For the 6.5405.000 cell without diaphragm and the 6.1464.32X and 6.1465.320 titration vessels.

    1 piece(s)

  • Sleeve
    6.2713.000
    Sleeve

    For the fat-free ground-joint connection with the standard ground-joint SGJ 14.


    2 piece(s)

  • Sleeve
    6.2713.010
    Sleeve

    Sleeve for the fat-free ground-joint connection with the standard ground-joint SGJ 29.


    1 piece(s)

  • Sleeve
    6.2713.020
    Sleeve

    For the fat-free ground-joint connection with the standard ground-joint SGJ 19.


    1 piece(s)

  • Stopper
    6.2730.030
    Stopper

    Complete with nipple and O-ring. For 6.1414.030 titration vessel lids. For KF instruments, VA measurement stands, VA Computrace and IC Dilution.

    1 piece(s)