NIRS XDS MultiVial Analyzer

NIRS XDS MultiVial Analyzer
Order number: 2.921.1210

Rapid, nondestructive analyses of solids in vials

The NIRS XDS MultiVial Analyzer enables rapid, nondestructive analyses of solid powders, coarser granulates, pellets or flakes.

Composition or material identification testing is performed either in the laboratory or at-line, on samples contained in their original packaging, bags or vials. An optional variable spot-size feature enables the sample illumination to be adjusted based on the physical properties of your samples.

The measurement of liquid samples succeeds through the addition of the NIRS Transflection Kit for liquid samples (order number: 6.7400.010).

Entire sample series are analyzed under full automation conditions with the MultiVial Analyzer. The NIRS XDS MultiVial Analyzer is equipped for this purpose with a sample slide that can be moved in x and y direction.

MultiVial trays for vials and/or tablets are available with predefined numbers of boreholes and bore sizes, although individual customized versions can also be produced to meet specific customer requirements.

 

  • Documents
  • Included parts
  • Opt. equipment
  • Brochure: NIRS XDS MultiVial Analyzer – Rapid, nondestructive analyses of solids in vials (english)
    • Prospekt: NIRS XDS MultiVial Analyzer – Schnelle, zerstörungsfreie Analysen von Feststoffen in Vials (deutsch)
  • Brochure: Spectroscopy solutions for pharmaceutical analysis – Faster, safer, and much more economical (english)
  • Declaration of Conformity for NIRS XDS Analyzers (english)
  • Manual for NIRS XDS MultiVial Analyzer (english)
    • NIRS XDS MultiVial Analyzer 手册 (中文)
    • Mode d’emploi NIRS XDS MultiVial Analyzer (français)
    • Handbuch NIRS XDS MultiVial Analyzer (deutsch)
    • Manual NIRS XDS MultiVial Analyzer (español)

Download the complete Scope of Delivery and Optional Accessories for as PDF:

  • NIRS XDS accessory kit
    6.7400.000
    NIRS XDS accessory kit

    Accessory kit for NIRS XDS laboratory monochromators

    1 piece(s)

  • NIRS XDS tray for reflection standard
    6.7410.000
    NIRS XDS tray for reflection standard

    A reflection standard is required for the calibration of the monochromator with the sample module.

    A holder in which the standard is positioned is used to fasten the calibration standard in place.
    A reflection standard and its associated holder are required for:

    • NIRS XDS MultiVial Analyzer (order number: 29211210)
    • NIRS XDS MasterLab Analyzer (order number: 2.921.1310)

    1 piece(s)

  • NIRS XDS iris
    6.7425.000
    NIRS XDS iris

    Iris for focusing mini sample vessels, reflection standard, various vials or a transflection vessel in the NIRS XDS RCA Analyzer, the NIRS XDS MasterLab Analyzer and the NIRS XDS MultiVial Analyzer

    1 piece(s)

Download the complete Scope of Delivery and Optional Accessories for as PDF:

  • Vision Air 2.0 Network Complete
    6.6072.207
    Vision Air 2.0 Network Complete

    Vision Air - Universal spectroscopy software.

    Vision Air Network is a modern and simple-to-operate software solution. The network version enables the structuring of a global server-client network with a central database.

    Overview of the advantages of Vision Air:
     

    • Individual software applications with adapted user interfaces ensure intuitive and simple operation
    • Centralized data and instrument management
    • Simple configuration and updating of several devices in just a few steps
       

    The Vision Air Network Complete version (66072207) contains all applications for quality assurance using Vis-NIR spectroscopy:
     

    • Application for a global instrument and data management
    • Application for method development
    • Application for routine analysis

     

  • Vision Air 2.0 Complete
    6.6072.208
    Vision Air 2.0 Complete

    Vision Air - Universal spectroscopy software.

    Vision Air Complete is a modern and simple-to-operate software solution for use in a regulated environment.

    Overview of the advantages of Vision Air:
     

    • Individual software applications with adapted user interfaces ensure intuitive and simple operation
    • Simple creation and maintenance of operating procedures
    • SQL database for secure and simple data management


    The Vision Air Complete version (66072208) includes all applications for quality assurance using Vis-NIR spectroscopy:
     

    • Application for instrument and data management
    • Application for method development
    • Application for routine analysis


    Additional Vision Air Complete solutions:
     

    • 66072207 (Vision Air Network Complete)
    • 66072209 (Vision Air Pharma Complete)
    • 66072210 (Vision Air Pharma Network Complete)

     

  • Vision Air 2.0 Pharma Complete
    6.6072.209
    Vision Air 2.0 Pharma Complete

    Vision Air - Universal spectroscopy software.

    Vision Air Pharma Complete is a modern and simple-to-operate software solution for use in regulated environments.

    Overview of the advantages of Vision Air:
     

    • Individual software applications with adapted user interfaces ensure intuitive and simple operation
    • Simple creation and maintenance of operating procedures
    • SQL database for safe and simple data management
    • In compliance with all requirements pursuant to Title 21 CFR Part 11


    The Vision Air Pharma Complete version (66072209) contains all applications for quality assurance using Vis-NIR spectroscopy:
     

    • Application for instrument and data management
    • Application for method development
    • Application for routine analysis

     

  • Vision Air 2.0 Pharma Network Complete
    6.6072.210
    Vision Air 2.0 Pharma Network Complete

    Vision Air - Universal spectroscopy software.

    Vision Air Pharma Network Complete is a modern and simple-to-operate software solution. The network version enables the setup of a global server-client network with a central database.

    Overview of the advantages of Vision Air:
     

    • Individual software applications with adapted user interfaces ensure intuitive and simple operation
    • Centralized data and instrument management
    • Simple configuration and updating of several instruments in just a few steps
    • In compliance with all requirements pursuant to Title 21 CFR Part 11


    The Vision Air Pharma Network Complete version (66072210) contains all applications for quality assurance using Vis-NIR spectroscopy:
     

    • Application for a global instrument and data management
    • Application for method development
    • Application for routine analysis
       

     

  • NIRS Liquid Sample Kit Transflection
    6.7400.010
    NIRS Liquid Sample Kit Transflection

    The NIRS Liquid Sample Kit Transflection supplements the following instruments with the function of the transflection measurement of liquids:

    • NIRS DS2500 Analyzer (order number: 2.922.0010)
    • NIRS XDS MasterLab Analyzer (order number: 2.921.1310)
    • NIRS XDS MultiVial Analyzer (order number: 2.921.1120)
    • NIRS XDS RapidContent Analyzer (order number: 2.921.1110)
    • NIRS XDS RapidContent Analyzer - Solids (order number: 2.921.1210)


     

  • NIRS transflection vessel, optically flat
    6.7401.000
    NIRS transflection vessel, optically flat

    Optically flat transflection vessel for the spectral measurement of liquids. Can be used in combination with the following instruments:

    • NIRS DS2500 Analyzer (order number: 2.922.0010)
    • NIRS XDS MasterLab Analyzer (order number: 2.921.1310)
    • NIRS XDS MultiVial Analyzer (order number: 2.921.1120)
    • NIRS XDS RapidContent Analyzer (order number: 2.921.1110)
    • NIRS XDS RapidContent Analyzer - Solids (order number: 2.921.1210)

     

  • NIRS disposable backs for 6.7402.030, 100 pcs.
    6.7402.020
    NIRS disposable backs for 6.7402.030, 100 pcs.

    The disposable backs are used for the secure sealing of the mini sample cups. The sample cups are used in the following:

    • NIRS DS2500 Analyzer (order number: 2.922.0010)
    • NIRS XDS MasterLab Analyzer (order number: 2.921.1310)
    • NIRS XDS RCA Analyzer (order number: 2.921.1110)
    • NIRS XDS MultiVial Analyzer (order number: 2.921.1210)

    The package is comprised of 100 disposable backs.

  • NIRS mini sample cups, 10 pcs. including 100 disposable backs 
    6.7402.030
    NIRS mini sample cups, 10 pcs. including 100 disposable backs 

    Mini sample cup for the spectral recording of powders and granulates in reflection. The sample cup can be sealed with disposable backs in order to avoid sample loss and for the uniform distribution of the powder or granulate in the sample cup.

    The sample cups are used with the following instruments:

    • NIRS DS2500 Analyzer (order number: 2.922.0010)
    • NIRS XDS MasterLab Analyzer (order number: 2.921.1310)
    • NIRS XDS MultiVial Analyzer (order number: 2.921.1120)
    • NIRS XDS RapidContent Analyzer (order number: 2.921.1110)
    • NIRS XDS RapidContent Analyzer - Solids (order number: 2.921.1210)
  • NIRS XDS coarse granular sample cell
    6.7402.040
    NIRS XDS coarse granular sample cell

    NIRS XDS coarse granular sample cell for the reflection measurement of samples with different surface properties.

  • Disposable vials 15 mm Reflection
    6.7402.110
    Disposable vials 15 mm Reflection

    192 lockable disposable glass vials with a diameter of 15 mm for analyses of solids in reflection. Suitable for the following analyzers:

    • NIRS DS2500 Analyzer
    • NIRS XDS RapidContent (Solid) Analyzer
    • NIRS XDS MultiVial Analyzer
    • NIRS XDS MasterLab Analyzer

     

  • Disposable vials 19 mm Reflection
    6.7402.120
    Disposable vials 19 mm Reflection

    232 lockable disposable glass vials with a diameter of 19 mm for analyses of solids in reflection. Suitable for the following analyzers:

    • NIRS DS2500 Analyzer
    • NIRS XDS RapidContent (Solid) Analyzer
    • NIRS XDS MultiVial Analyzer
    • NIRS XDS MasterLab Analyzer

     

  • Disposable vials 22 mm Reflection
    6.7402.130
    Disposable vials 22 mm Reflection

    192 lockable disposable glass vials with a diameter of 22 mm for analyses of solids in reflection. Suitable for the following Analyzers:

    • NIRS DS2500 Analyzer
    • NIRS XDS RapidContent (Solid) Analyzer
    • NIRS XDS MultiVial Analyzer
    • NIRS XDS MasterLab Analyzer

     

  • Disposable vials 28 mm Reflection
    6.7402.140
    Disposable vials 28 mm Reflection

    216 lockable disposable glass vials with a diameter of 28 mm for analyses of solids in reflection. Suitable for the following Analyzers:

    • NIRS DS2500 Analyzer
    • NIRS XDS RapidContent (Solid) Analyzer
    • NIRS XDS MultiVial Analyzer
    • NIRS XDS MasterLab Analyzer

     

  • Stopper for 6.7402.120
    6.7402.210
    Stopper for 6.7402.120

    232 stoppers for 19 mm Reflection disposable vials.

  • Stopper for 6.7402.130
    6.7402.220
    Stopper for 6.7402.130

    192 stoppers for 22 mm Reflection disposable vials.

  • Stopper for 6.7402.140
    6.7402.230
    Stopper for 6.7402.140

    216 stoppers for 28 mm Reflection disposable vials.

  • NIRS MultiVial tray for 4x5 15 mm vials
    6.7410.010
    NIRS MultiVial tray for 4x5 15 mm vials

    NIRS MultiVial tray for 4x5 15 mm vials

  • NIRS MultiVial tray for 3x5 19 mm vials
    6.7410.020
    NIRS MultiVial tray for 3x5 19 mm vials

    NIRS MultiVial tray for 3x5 19 mm vials

  • NIRS MultiVial tray for 3x5 22 mm vials
    6.7410.030
    NIRS MultiVial tray for 3x5 22 mm vials

    NIRS MultiVial tray for 3x5 22 mm vials

  • NIRS MultiVial tray for 2x3 27 mm vials
    6.7410.040
    NIRS MultiVial tray for 2x3 27 mm vials

    NIRS MultiVial tray for 2x3 27 mm vials

  • NIRS MultiVial tray for 2x3 29 mm vials
    6.7410.050
    NIRS MultiVial tray for 2x3 29 mm vials

    NIRS MultiVial tray for 2x3 29 mm vials

  • NIRS gold diffuse reflector, 1 mm total pathlength
    6.7420.000
    NIRS gold diffuse reflector, 1 mm total pathlength

    Gold diffuse reflector for the transflection measurement of liquids. Can be used in combination with the following instruments:

    • NIRS DS2500 Analyzer (order number: 2.922.0010)
    • NIRS XDS MasterLab Analyzer (order number: 2.921.1310)
    • NIRS XDS MultiVial Analyzer (order number: 2.921.1120)
    • NIRS XDS RapidContent Analyzer (order number: 2.921.1110)
    • NIRS XDS RapidContent Analyzer - Solids (order number: 2.921.1210)

     

  • NIRS gold diffuse reflector, 2 mm total pathlength
    6.7420.010
    NIRS gold diffuse reflector, 2 mm total pathlength

    Gold diffuse reflector for the transflection measurement of liquids. Can be used in combination with the following instruments:

    • NIRS DS2500 Analyzer (order number: 2.922.0010)
    • NIRS XDS MasterLab Analyzer (order number: 2.921.1310)
    • NIRS XDS MultiVial Analyzer (order number: 2.921.1120)
    • NIRS XDS RapidContent Analyzer (order number: 2.921.1110)
    • NIRS XDS RapidContent Analyzer - Solids (order number: 2.921.1210)

     

  • NIRS gold diffuse reflector, 4 mm total pathlength
    6.7420.020
    NIRS gold diffuse reflector, 4 mm total pathlength

    Gold diffuse reflector for the transflection measurement of liquids. Can be used in combination with the following instruments:

    NIRS DS2500 Analyzer (order number: 2.922.0010)
    NIRS XDS MasterLab Analyzer (order number: 2.921.1310)
    NIRS XDS MultiVial Analyzer (order number: 2.921.1120)
    NIRS XDS RapidContent Analyzer (order number: 2.921.1110)
    NIRS XDS RapidContent Analyzer - Solids (order number: 2.921.1210)

     

  • NIRS XDS lab spare lamp
    6.7430.000
    NIRS XDS lab spare lamp

    Spare lamp with 12 V and 50 W for the monochromator of the NIRS XDS laboratory instruments

  • NIRS XDS lab spare parts kit
    6.7430.010
    NIRS XDS lab spare parts kit

    NIRS XDS lab spare parts kit

  • NIRS XDS Monochromator fan filter, 10 pcs.
    6.7430.020
    NIRS XDS Monochromator fan filter, 10 pcs.

    Ten NIRS XDS fan filters for the monochromator

  • Micro Fiber Cleaning Cloth
    6.7430.060
    Micro Fiber Cleaning Cloth

    Cleaning cloth for monitors and optics.

  • NIRS reflection standard, set of 2
    6.7450.000
    NIRS reflection standard, set of 2

    Set of wavelength standard and 80% reflection standard for the calibration of an NIRS XDS MasterLab Analyzer, NIRS XDS RCA Analyzer, NIRS XDS MultiVial Analyzer, NIRS XDS SmartProbe Analyzer, NIRS XDS Interactance OptiProbe Analyzer and NIRS DS2500 Analyzer.

  • NIRS reflection standard, set of 7
    6.7450.010
    NIRS reflection standard, set of 7

    Set comprised of six reflection standards and one wavelength standard for the calibration of an NIRS XDS MasterLab Analyzer, NIRS XDS RCA Analyzer, NIRS XDS MultiVial Analyzer, NIRS XDS SmartProbe Analyzer, NIRS XDS Interactance OptiProbe Analyzer and NIRS DS2500 Analyzer in regulated environments.