Application Finder
- AB-071pH value and oxidation reduction potential in soil samples – Determination according to EN 15933, ISO 10390, and ASTM D4972
The pH value and oxidation reduction potential (ORP) of soil provide important information about soil properties, such as solubility of minerals and ion mobility. Knowledge of these properties allows making predictions concerning plant growth, bacterial activity, nutrients that may be needed, possible corrosive effects on buildings, etc.Here, the determination of the pH value is described according to ISO 10390, EN 15933 and ASTM D4972. Th oxidation reduction potential determination is carried out in a suspension.
- AN-COR-005Corrosion part 5 – corrosion Inhibitors
A corrosion inhibitor is a substance that reduces the corrosion rate of a metal. A corrosion inhibitor is usually added in a small concentration to the corrosive environment. This application note shows how Metrohm Autolab instruments can be used to check the quality of inhibitors.
- AN-EC-002Reference electrodes and their usage
A reference electrode has a stable and well-defined electrochemical potential (at constant temperature), against which the applied or measured potentials in an electrochemical cell are referred. A good reference electrode is therefore stable and non-polarizable. In other words, the potential of such an electrode will remain stable in the used environment and also upon the passage of a small current. This application note lists the most used reference electrodes, together with their range of use.
- AN-EC-015Metrohm 663 VA stand for Heavy Metal Ions detection in Water Sample
The determination of heavy metal ions in a solution is one of the most successful application of electrochemistry. In this application note, anodic stripping voltammetry is used to measure the presence of two analytes, in a sample of tap water.
- WP-055Corrosion Best Practice – Creating Pipe-flow Conditions Using a Rotating Cylinder Electrode
Electrochemical measurements utilizing a rotating cylinder electrode (RCE) are widely used in industrial corrosion applications when simulation of realistic pipe conditions are necessary in a lab environment. This white paper allows further insight into the particularities and parameters which govern the electrochemical measurements, in particular measurements performed in turbulent flow conditions, and shows a complete picture of the best practice use of this technique. The annexes provide an overview and short explanation of the parameters and laws specific to the fluid behavior in electrochemical cells with RCE.