945 Professional Detector Vario – Amperometry

945 Professional Detector Vario – Amperometry
Order Number: 2.945.0020

Intelligent stand-alone detector equipped with the IC Amperometric Detector. Outstanding selectivity due to the four measuring modes: DC, PAD, flexIPAD, CV. The excellent signal/noise ratio and the very fast start-up guarantee the highest in measurement precision. For use with intelligent IC instruments or as independent detector.

  • Documents
  • Included parts
  • Options
  • Brochure: 945 Professional Detector Vario IC Amperometric Detector – Amperometric detection for the determination of electroactive substances (english)
    • Prospekt: 945 Professional Detector Vario IC Amperometric Detector – Amperometrische Detektion zur Bestimmung elektroaktiver Substanzen (deutsch)
  • Declaration of Conformity for 945 Professional Detector Vario (english)
  • Manual for 29450020 Professional Detector Vario Amp (english)
    • 29450020 Professional Detector Vario Amp 手册 (中文)
    • Mode d’emploi 29450020 Professional Detector Vario Amp (français)
    • Handbuch 29450020 Professional Detector Vario Amp (deutsch)
    • Manual 29450020 Professional Detector Vario Amp (español)

Download the complete Scope of Delivery and Optional Accessories for as PDF:

  • PEEK capillary 0.25 mm i.d. / 3 m
    6.1831.010
    PEEK capillary 0.25 mm i.d. / 3 m
    For all IC components.

    1 piece(s)

  • Cable USB A - USB B  1.8 m
    6.2151.020
    Cable USB A - USB B 1.8 m
    USB connecting cable

    1 piece(s)

  • Connecting cable to 61257XXX
    6.2165.000
    Connecting cable to 61257XXX
    Connecting cable for amperometric detector cell.

    1 piece(s)

  • Pressure screw 2x
    6.2744.014
    Pressure screw 2x
    With UNF 10/32 connection. For the connection of PEEK capillaries

    1 piece(s)

  • 
      
    Dummy cell to the IC Amperometric Detector.
    6.2813.040
    Dummy cell to the IC Amperometric Detector.
    Dummy cell for performance tests.

    1 piece(s)

Download the complete Scope of Delivery and Optional Accessories for as PDF:

  • Wall-Jet Cell
    6.1257.010
    Wall-Jet Cell

    Amperometric detector cell with Wall-Jet geometry.

  • 
    Thin-Layer cell
    6.1257.100
    Thin-Layer cell

    Amperometric detector cell with Thin-Layer geometry. For special applications and systems with higher backpressure (e.g. amperometry MS couplings).


  • 
    Au working electrode, 3 mm
    6.1257.210
    Au working electrode, 3 mm
    Working electrode made of gold for amperometric detection, 3 mm diameter.
  • GC working electrode
    6.1257.220
    GC working electrode

    Working electrode made of Glassy Carbon for amperometric detection, 3 mm diameter.


  • Pt working electrode
    6.1257.230
    Pt working electrode
    Platinum working electrode for amperometric detection, 3 mm diameter.
  • Ag working electrode
    6.1257.240
    Ag working electrode
    Silver working electrode for amperometric detection, 3 mm diameter.
  • 
    Au working electrode, 2 mm
    6.1257.260
    Au working electrode, 2 mm
    Working electrode made of gold for amperometric detection, 2 mm diameter.
  • Cu working electrode, 2 mm
    6.1257.270
    Cu working electrode, 2 mm

    Working electrode made of copper for amperometric detection, 2 mm diameter. Alternative working electrode for the gold electrode in carbohydrate analysis.

  • 
      
    Ag/AgCl reference electrode for 6.1257.xxx
    6.1257.720
    Ag/AgCl reference electrode for 6.1257.xxx


    Silver/silver chloride reference electrode for amperometric detection.


  • Pd reference electrode to 6.1257.xxx
    6.1257.740
    Pd reference electrode to 6.1257.xxx

    Palladium reference electrode for amperometric detection.

  • 50 µm spacer for the Wall-Jet cell.
    6.1257.810
    50 µm spacer for the Wall-Jet cell.

    50 µm spacer for the amperometric Wall-Jet cell, 3 pcs.

  • 
    50 µm spacer to Thin-Layer cell
    6.1257.820
    50 µm spacer to Thin-Layer cell

    50 µm spacer for the amperometric Thin-Layer cell, 3 pcs.


  • 25 µm spacer for the Wall-Jet cell
    6.1257.830
    25 µm spacer for the Wall-Jet cell

    25 µm spacer for the amperometric Wall-Jet cell, 3 pcs.

  • 
    25 µm spacer to Thin-Layer cell
    6.1257.840
    25 µm spacer to Thin-Layer cell

    25 µm spacer for the amperometric Thin-Layer cell, 3 pcs.


  • Accessory kit: IC Amperometric Detector
    6.5000.200
    Accessory kit: IC Amperometric Detector

    Optional accessory kit for the IC Amperometric Detector for determinations in low-conductivity solutions.

  • IC equipment Wall-Jet cell: without electrodes
    6.5337.000
    IC equipment Wall-Jet cell: without electrodes

    Equipment comprised of Wall-Jet cell with additional accessories, without electrode.

  • IC equipment Wall-Jet cell: Carb (Au, Pd)
    6.5337.010
    IC equipment Wall-Jet cell: Carb (Au, Pd)

    Equipment comprised of Wall-Jet cell with additional accessories. For carbohydrate analysis with a gold working electrode and a Pd reference electrode.

  • IC equipment Wall-Jet cell: Cyanide (Ag, Pd)
    6.5337.020
    IC equipment Wall-Jet cell: Cyanide (Ag, Pd)

    Equipment comprised of Wall-Jet cell with additional accessories. For cyanide analysis with a silver working electrode and a Pd reference electrode.

  • IC equipment Wall-Jet cell: Anion (GC, Ag/AgCl).
    6.5337.030
    IC equipment Wall-Jet cell: Anion (GC, Ag/AgCl).

    Equipment comprised of Wall-Jet cell with additional accessories. For anion analysis with a Glassy Carbon and an Ag/AgCl reference electrode.

  • IC equipment Thin-Layer cell: without electrodes
    6.5337.200
    IC equipment Thin-Layer cell: without electrodes

    Equipment comprised of Thin-Layer cell with additional accessories, without electrodes.

  • MagIC Net 3.2 Professional CD: 1 license
    6.6059.322
    MagIC Net 3.2 Professional CD: 1 license

    Professional PC program for controlling all of the intelligent Professional IC systems, Compact IC instruments and their peripherals, such as various Autosamplers, 800 Dosinos, 771 Compact Interface, etc. The software permits the inspection, data acquisition, data evaluation, data monitoring and report generation of ion chromatographic analyses.

    Graphical user interface for routine operations, extensive database programs, method development, configuration and manual system control; very flexible user administration, efficient database operations, extensive data export functions, individually configurable report generator, control and monitoring of all system components and the chromatography results.

    MagIC Net Professional complies fully with FDA Regulation 21 CFR Part 11 as well as GLP.

    MagIC Net is available in 16 dialog languages.

    1 license.

  • MagIC Net 3.2 Multi CD: 3 licenses
    6.6059.323
    MagIC Net 3.2 Multi CD: 3 licenses

    Professional PC program for controlling all of the intelligent Professional IC systems, Compact IC instruments and their peripherals, such as various Autosamplers, 800 Dosinos, 771 Compact Interface, etc. The software permits the inspection, data acquisition, data evaluation, data monitoring and report generation of ion chromatographic analyses.

    Graphical user interface for routine operations, extensive database programs, method development, configuration and manual system control; very flexible user administration, efficient database operations, extensive data export functions, individually configurable report generator, control and monitoring of all system components and the chromatography results.

    MagIC Net Multi complies fully with FDA Regulation 21 CFR Part 11 as well as with GLP.

    MagIC Net is available in 16 dialog languages.

    Client/server version with 3 licenses.

  • Metrohm IC Driver 2.0 for Empower
    6.6070.200
    Metrohm IC Driver 2.0 for Empower

    Software drivers for integrating Metrohm IC instruments in "Empower" from Waters. One license authorizes the operation of one IC system under "Empower".