Dimensions in mm (W/H/D) 405/353/466
Dimensions remark Height with accessories

Heating

  • 2 individually heated aluminum heating blocks


Max. number of samples

  • 8 (4 in each block)


Temperature range

  • 50 - 220°C, can be set in increments of 1°C


Temperature correction

  • -9.9 - +9.9°C, can be set in increments of 0.1°C


Max. deviation from the set temperature

  • < 0.3°C


Reproducibility of the set temperature

  • < 0.2°C


Stability of the temperature (max. temperature fluctuation)

  • < 0.1°C


Temperature differential between the individual measurement positions

  • < 0.3°C


Heating up time from 20°C

  • to 120°C: approx. 45 min
  • to 220°C: approx. 60 min


Gas supply

  • From external nitrogen bottle


Gas flow range

  • 4 - 15 L/h


Conductivity measurement

  • 0 - 500 µS/cm


Interface

  • RS-232 C


Software

  • Metrodata 763 PVC Thermomat Software 1.1

Download the complete Scope of Delivery and Optional Accessories for as PDF:

  • Measuring vessel cover for stability measuring instruments
    6.0913.130
    Measuring vessel cover for stability measuring instruments
    With built-in conductometric measuring cell.

    8 piece(s)

  • Reaction vessel short for stability measurements
    6.1429.040
    Reaction vessel short for stability measurements


    Reaction vessel for stability measurements with Rancimat and PVC Thermomat. Set of 117 pieces.


    1 piece(s)

  • O-Ring
    6.1454.040
    O-Ring


    O-ring for air tube for stability measurements. Set of 8 pieces.


    4 piece(s)

  • PVC tubing / 4 mm / 7 mm / 1 m
    6.1801.000
    PVC tubing / 4 mm / 7 mm / 1 m

    1 piece(s)

  • FEP tubing / M6 / 150 cm
    6.1805.030
    FEP tubing / M6 / 150 cm
    With light and kink protection

    1 piece(s)

  • FEP tubing / M6 / 25 cm
    6.1805.080
    FEP tubing / M6 / 25 cm
    With light and kink protection.

    8 piece(s)

  • Tubing adapter olive / M6 inner
    6.1808.020
    Tubing adapter olive / M6 inner
    1 M6 inner thread and 1 tubing nozzle. Part of the screw connections for Exchange Units and stability measuring instruments.

    1 piece(s)

  • Tubing adapter olive / M8 outer
    6.1808.050
    Tubing adapter olive / M8 outer
    1 M8 outer thread and 1 tubing olive. E.g. for thermostat jacket of exchange units and stability measuring instruments.

    16 piece(s)

  • Thread adapter M8 outer / M6 inner
    6.1808.090
    Thread adapter M8 outer / M6 inner
    Outer thread M8, inner thread M6, e.g. for mounting 6.2418.XXX Air tubes in 6.1429.XXX Reaction vessels of stability measuring instruments.

    8 piece(s)

  • Silicone tubing 0.22 m
    6.1816.010
    Silicone tubing 0.22 m
    Connection tubing for stability measuring instruments.

    24 piece(s)

  • Cannula for gas feeding
    6.1819.080
    Cannula for gas feeding
    For stability measuring instruments.

    8 piece(s)

  • Holder for reaction vessels
    6.2041.190
    Holder for reaction vessels
    Reaction vessel holder for stability instruments; for 8 reaction vessels.

    1 piece(s)

  • RS-232 cable, 5 m, DB9 – DB9
    6.2134.100
    RS-232 cable, 5 m, DB9 – DB9
    Connecting Metrohm RS-232 interface to Titrinos, 756 KF Coulometer, 762 or 771 IC Interfaces, 790 Personal IC, 743 Rancimat, 763 PVC Thermomat, 873 Biodiesel Rancimat.

    1 piece(s)

  • Labels laminated
    6.2250.000
    Labels laminated
    Labels for measuring vessel cover for stability measuring instruments. Labeling: A1, A2, A3, A4, B1, B2, B3, B4. 5 sets of 8 items each.

    1 piece(s)

  • Gas inlet tube for PVC measurements
    6.2418.120
    Gas inlet tube for PVC measurements
    Set of 117 pieces. In combination with 6.1429.040.

    1 piece(s)

  • Holder for reaction vessel
    6.2628.000
    Holder for reaction vessel
    Reaction vessel holder for stability instruments; for 1 reaction vessel for weighing in the sample.

    1 piece(s)

  • Reaction vessel cover for stability measurements
    6.2753.107
    Reaction vessel cover for stability measurements
    For 6.1429.040 or 6.1429.050 Reaction vessel. Set of 100 pieces.

    1 piece(s)

  • 763 PVC Thermomat Software 1.1
    6.6037.010
    763 PVC Thermomat Software 1.1

    Software for instrument control and administration of data. For the following operating systems: Windows ® 2000, Windows ® XP Professional, Windows ® Vista (32-bit) and Windows ® 7 (32-bit).


     


    1 piece(s)

Download the complete Scope of Delivery and Optional Accessories for as PDF:

  • 2.145.0320
    Port extension USB - 4xDB9 
    For connection (DB9) of 4 additional instruments to the USB interface of the computer (WIN98, 2000 or XP).
  • Pt100 temperature sensor for stability measuring devices
    6.1111.010
    Pt100 temperature sensor for stability measuring devices

    Pt100 temperature sensor (length 17.5 cm) with fixed cable and mini-DIN-plug. This glass-free temperature sensor is well suited for use with a 711 Liquino and instruments for stability measurement (743 Rancimat, 763 PVC Thermomat, 892 Professional Rancimat, or 895 Professional PVC Thermomat).

  • Glass measuring vessel for stability measurements
    6.1428.030
    Glass measuring vessel for stability measurements


    Conductivity measuring vessel made of clear glass for stability measuring devices


  • Turning ring
    6.2059.000
    Turning ring
    Turning ring for the swiveling setup of stability measuring instruments.
  • RS-232 cable 3 m, 25-pin – 9-pin
    6.2125.110
    RS-232 cable 3 m, 25-pin – 9-pin
    Connecting Metrohm RS-232 interface to PC. Used with pH Meters, Titrinos, KF Coulometers, VA Trace Analyzer.
  • KCl ion standard 250 mL
    6.2301.060
    KCl ion standard 250 mL

    KCl ion standard (c(ion) = 0.1000 +/-0.0005 mol/L), can also be used as standard solution for conductometry 12.87 mS/cm (25 °C).

  • Conductivity standard 100 µS/cm 250 mL
    6.2324.010
    Conductivity standard 100 µS/cm 250 mL
    Conductivity standard for calibration of conductivity measuring cells with cell constant = 0.1/cm.
  • Silicone oil for stability measuring instruments (50 mL)
    6.2326.000
    Silicone oil for stability measuring instruments (50 mL)


    Silicone oil for the determination of temperature correction in stability measuring instruments


  • Air collection tube for stability measuring instruments
    6.2757.000
    Air collection tube for stability measuring instruments
    Including 8 stoppers.
  • Aspiration filter
    6.2821.090
    Aspiration filter
    Pore size 20 µm, set of 5 pieces. For 6.1834.000 Aspiration tubing and 6.1821.040 and 6.1821.050 Filter tubes.
  • 
    Equipment for determination of temperature correction with Rancimats and PVC Thermomats.
    6.5616.100
    Equipment for determination of temperature correction with Rancimats and PVC Thermomats.

    Set for exact temperature adjustment