761 Compact IC

761 Compact IC
Order number: 2.761.0010
PC-controlled compact IC system for the analysis of anions and cations without chemical suppression. With built-in double-piston pump, electrically operated injection valve, temperature-stabilized high-performance detector and data acquisition.
  • Tech specs
  • Documents
  • Included parts
  • Opt. equipment
Dimensions in mm (W/H/D) 259/446/355

Compact high-performance ion chromatography system with (2.761.0020) or without (2.761.0010) chemical suppression

  • Built-in six-way injection valve
  • Low-pulsation dual-piston pump, flow range 0.2 to 2.5 mL/min, maximum pressure 25 MPa (250 bar, 3625 psi)
  • Pulsation absorber
  • Insulated column compartment
  • Eluent organizer
  • Detector temperature-stabilized to better than 0.01 °C, temperature range 25...45 °C in 5 °C steps, three measuring ranges 0...50 µS/cm, 0...250 µS/cm, 0...1000 µS/cm
  • Analog output 0...1000 mV
  • Metrohm Suppressor Module «MSM» (2.761.0020 only)
  • Built-in 22-bit AD converter
  • 8 remote output lines for controlling external devices
  • Software for control and integration
  • Free-of-charge application updates from the Internet

Download the complete Scope of Delivery and Optional Accessories for as PDF:

  • Bottle attachment GL 45 for eluents and reagents
    6.1602.160
    Bottle attachment GL 45 for eluents and reagents

    For eluent, reagent, and rinsing bottles, with connectors for the adsorber tube and the aspiration tubing.

    1 piece(s)

  • Eluent bottle / 2 L / GL 45
    6.1608.070
    Eluent bottle / 2 L / GL 45

    1 piece(s)

  • Adsorbing tube, large and bent
    6.1609.000
    Adsorbing tube, large and bent
    For filling with adsorber material.

    1 piece(s)

  • Silicone tubing 6 mm i.d., 1 m
    6.1816.020
    Silicone tubing 6 mm i.d., 1 m
    For waste tubing.

    2 piece(s)

  • PTFE aspiration tube to IC Pump, 2.5 m
    6.1834.010
    PTFE aspiration tube to IC Pump, 2.5 m
    For Compact IC, Personal IC, Basic IC, 6.5324.000 bottle holder.

    1 piece(s)

  • Clip for SGJ 14/15
    6.2023.020
    Clip for SGJ 14/15
    Clip for SGJ 14/16

    1 piece(s)

  • Column holder 8.5 mm
    6.2027.030
    Column holder 8.5 mm
    For mounting columns in column chamber of IC instruments.

    1 piece(s)

  • Column holder 11.3 mm
    6.2027.040
    Column holder 11.3 mm
    For mounting columns in column chamber of IC instruments.

    1 piece(s)

  • RS-232 cable, 5 m, DB9 – DB9
    6.2134.100
    RS-232 cable, 5 m, DB9 – DB9
    Connecting Metrohm RS-232 interface to Titrinos, 756 KF Coulometer, 762 or 771 IC Interfaces, 790 Personal IC, 743 Rancimat, 763 PVC Thermomat, 873 Biodiesel Rancimat.

    1 piece(s)

  • Tool for piston seal
    6.2617.010
    Tool for piston seal
    For removing and assembling the piston seal for all standard pump heads

    1 piece(s)

  • Pulsation absorber (metal-free)
    6.2620.150
    Pulsation absorber (metal-free)
    For all ion chromatographs

    1 piece(s)

  • Adjustable wrench
    6.2621.000
    Adjustable wrench
    Max. opening: 20 mm. For IC instruments

    1 piece(s)

  • Hexagon key 4 mm
    6.2621.030
    Hexagon key 4 mm

    1 piece(s)

  • Pressure screw 5x
    6.2744.010
    Pressure screw 5x
    With UNF 10/32 connection. For the connection of PEEK capillaries

    1 piece(s)

  • Luer/UNF coupling
    6.2744.020
    Luer/UNF coupling
    For IC instruments

    1 piece(s)

  • Syringe 10 mL with Luer connection
    6.2816.020
    Syringe 10 mL with Luer connection
    For various applications in IC and VA

    1 piece(s)

  • Aspiration filter
    6.2821.090
    Aspiration filter
    Pore size 20 µm, set of 5 pieces. For 6.1834.000 Aspiration tubing and 6.1821.040 and 6.1821.050 Filter tubes.

    1 piece(s)

  • Spare filter for inline filter
    6.2821.130
    Spare filter for inline filter
    Spare filter for inline filter.

    1 piece(s)

Download the complete Scope of Delivery and Optional Accessories for as PDF:

  • PTFE capillary 0.5 mm i.d. / 3 m
    6.1803.030
    PTFE capillary 0.5 mm i.d. / 3 m
    Capillary for inline dialysis, for Dialysis Unit, IC Dialysis Sample Processor, IC Liquid Handling Dialysis Unit
  • Holder for dialysis cell
    6.2057.010
    Holder for dialysis cell
    For the dialysis cell in IC column chambers
  • Cable 771 (analog) - 819
    6.2134.140
    Cable 771 (analog) - 819
    Connection of analog and start signals to 771
  • Cable 766/788/813/838 - 761/790/861
    6.2141.130
    Cable 766/788/813/838 - 761/790/861
    Connecting 766, 788, 813, 838-761, 790, 861 IC instruments. Only for sending the sample changer start signal.
  • Piston seal (orange)
    6.2741.020
    Piston seal (orange)
    For all standard pump heads
  • Zirconium oxide piston
    6.2824.070
    Zirconium oxide piston
    Pump piston for all standard pump heads
  • Rotor for flat plate injector (metal-free)
    6.5904.030
    Rotor for flat plate injector (metal-free)
    For all IC instruments with metal-free injectors
  • Injector with 0.25 µL internal loop
    6.5904.050
    Injector with 0.25 µL internal loop
    Flat plate injector with 0.25 µL internal loop
  • Rotor (internal loop, 0.25 µL)
    6.5904.060
    Rotor (internal loop, 0.25 µL)

    Rotor for 4-port flat plate injector (6.5904.050), 0.25 µL internal loop

  • Rotor (internal loop, 1.0 µL)
    6.5904.070
    Rotor (internal loop, 1.0 µL)

    Rotor for 4-port flat plate injector (6.9956.001), 1.0 µL internal loop