899 Coulometer with generator electrode without diaphragm and Neo's USB thermal printer

899 Coulometer with generator electrode without diaphragm and Neo's USB thermal printer
Order number: 2.899.1110

Thanks to the integrated stirrer, the 899 Coulometer takes up less space on the laboratory table than a sheet of DIN A4 paper. Although small and compact, the coulometer does not compromise on performance. Water contents can be determined with precision down to trace levels. Indicator electrode, generator electrode without diaphragm and a Neo's USB thermal printer are included in the scope of delivery.

Recommended measuring range: 10 µg - 200 mg absolute water

Coulometry is the ideal method for water content determination in liquids, solids and gases in the trace range. In addition, coulometry is an absolute method and thus no titer determination is necessary.

  • Documents
  • Included parts
  • Opt. equipment
  • Brochure: 899 Coulometer - Mobile coulometer for water determination anywhere you want (english)
    • Prospectus: 899 Coulometer - Coulomètre mobile compact avec fonctionnement sur batterie (en option) (français)
    • Prospekt: 899 Coulometer - Mobiles Kompakt-Coulometer mit optionalem Batteriebetrieb  (deutsch)
    • Folleto: 899 Coulometer - Coulómetro portátil para determinar el contenido de agua en cualquier lugar (español)
  • Declaration of conformity:  899 Coulometer (english)
  • Manual - Short instructions 899 Coulometer (english)
    • 899 Coulometer(电量计)简介手册 (中文)
    • Mode d'emploi – Guide rapide 899 Coulometer (français)
    • Handbuch — Kurzanleitung 899 Coulometer (deutsch)
    • ハンドブック – クイックスタートガイド 899 Coulometer (日本語)
    • Manual – Guía rápida 899 Coulometer (español)
  • Manual 899 Coulometer (english)
    • 899 Coulometer(电量计)手册 (中文)
    • Mode d'emploi 899 Coulometer (français)
    • Handbuch 899 Coulometer (deutsch)
    • Manual 899 Coulometer (español)
  • Release Notes 848, 870, 877, 865, 876, 862, 885, 899   (english)

Download the complete Scope of Delivery and Optional Accessories for as PDF:

  • Double Pt-wire electrode for coulometry
    6.0341.100
    Double Pt-wire electrode for coulometry

    Indicator electrode used for coulometric Karl Fischer titration.

    1 piece(s)

  • Generator electrode without diaphragm
    6.0345.100
    Generator electrode without diaphragm

    Generator electrode without diaphragm for coulometric Karl Fischer titrations, SGJ 29/22.
    This generator electrode is well suited for most applications where the sample is highly soluble in alcohol.

    1 piece(s)

  • KF adsorber tube for coulometer cell
    6.1403.030
    KF adsorber tube for coulometer cell

    For KF coulometers.


    1 piece(s)

  • SGJ stopper SGJ 14
    6.1437.000
    SGJ stopper SGJ 14

    1 piece(s)

  • Septum 16 mm, 5 pieces
    6.1448.020
    Septum 16 mm, 5 pieces
    Set of 5 pcs.

    2 piece(s)

  • KF titration vessel / 80-250 mL / coulometric
    6.1464.320
    KF titration vessel / 80-250 mL / coulometric

    1 piece(s)

  • Stirring bar / 25 mm
    6.1903.030
    Stirring bar / 25 mm

    Stirring bar with magnetic core, PTFE covering, length 25 mm.


    1 piece(s)

  • Titration vessel holder for 899/917
    6.2047.040
    Titration vessel holder for 899/917

    Titration vessel holder for coulometric cells for 899 Coulometer and 917 Ti-Touch

    1 piece(s)

  • Adapter red  2 mm plug / 4 mm socket
    6.2103.130
    Adapter red 2 mm plug / 4 mm socket
    For connecting plug B (4 mm) to 2 mm socket.

    1 piece(s)

  • Adapter black 2 mm plug / B socket 4 mm
    6.2103.140
    Adapter black 2 mm plug / B socket 4 mm
    For connecting plug B (4 mm) to 2 mm socket.

    1 piece(s)

  • Electrode cable / 1 m / F
    6.2104.020
    Electrode cable / 1 m / F
    For connecting electrodes with Metrohm plug-in head G to Metrohm instruments (socket F).

    1 piece(s)

  • Electrode cable / 1 m / H
    6.2104.120
    Electrode cable / 1 m / H
    With plug H. For connecting generator electrode - KF Coulometer.

    1 piece(s)

  • Numerical USB keypad
    6.2147.000
    Numerical USB keypad

    Numerical USB keypad for Titrino plus, Dosimat plus, 862 Compact Titrosampler, 869 Compact Sample Changer, 863 Compact Autosampler and 899 Coulometer. With two integrated USB connectors.

    1 piece(s)

  • Adapter USB MINI (OTG) - USB A
    6.2151.100
    Adapter USB MINI (OTG) - USB A
    For connecting USB instruments.

    1 piece(s)

  • Cable USB MINI (OTG) - USB B, 1.8 m
    6.2151.120
    Cable USB MINI (OTG) - USB B, 1.8 m
    For connecting USB instruments.

    1 piece(s)

  • Power supply unit 100 - 240 V/24 V DC
    6.2164.010
    Power supply unit 100 - 240 V/24 V DC
    Power supply unit for 915 KF Ti-Touch and 916 Ti-Touch

    1 piece(s)

  • 
    GL 18 screw cap with hole
    6.2701.040
    GL 18 screw cap with hole
    Made of PBT. With a hole for the 6.1448.020 septum. For the 6.5405.000 cell without diaphragm and the 6.1464.32X and 6.1465.320 titration vessels.

    1 piece(s)

  • Sleeve
    6.2713.000
    Sleeve

    For the fat-free ground-joint connection with the standard ground-joint SGJ 14.


    3 piece(s)

  • Sleeve
    6.2713.010
    Sleeve

    Sleeve for the fat-free ground-joint connection with the standard ground-joint SGJ 29.


    1 piece(s)

  • Sleeve
    6.2713.020
    Sleeve

    For the fat-free ground-joint connection with the standard ground-joint SGJ 19.


    1 piece(s)

  • Protective cover for Titrino plus
    6.2723.310
    Protective cover for Titrino plus

    Protective cover for display and keypad for all instruments of the Titrino plus family.


    Suitable for: 848 Titrino plus, 862 Compact Titrosampler, 863 Compact Autosampler, 865 Dosimat plus, 869 Compact Sample Changer, 870 KF Titrino plus, 876 Dosimat plus, 877 Titrino plus, 899 Coulometer.


     


    1 piece(s)

  • Funnel
    6.2738.000
    Funnel

    For the KF coulometer.


    1 piece(s)

  • Molecular sieve
    6.2811.000
    Molecular sieve
    Molecular sieve. Bottle containing 250 g. Pore size: 0.3 nm. Without moisture indicator. For Rancimats and Karl Fischer instruments.

    1 piece(s)

  • Needle with Luer connector
    6.2816.030
    Needle with Luer connector

    Needle for filling in mercury into the Multi-Mode Electrode and for sample addition in Karl Fischer titration.


     


    2 piece(s)

  • Syringe 5 mL
    6.2816.090
    Syringe 5 mL

    5 mL syringe made of PP, with Luer connector.


    2 piece(s)

  • Thermal paper for Custom Neos-N / Q3X
    6.9001.050
    Thermal paper for Custom Neos-N / Q3X

    Thermal paper 60 mm / 25 m for Custom Neos-N / Q3X.
    New: 25-year legibility with correct storage.

    1 role

    4 piece(s)

Download the complete Scope of Delivery and Optional Accessories for as PDF:

  • 
    801 Stirrer
    2.801.0010
    801 Stirrer

    Magnetic stirrer without stand for supplementing the Titrino plus, Dosimat plus, Titrandos, Sample Processors, 805 Dosimats and 780/781 pH Meters. With permanently attached cable for MSB (Metrohm Serial Bus).


  • 803 TI Stand with stirrer and pump
    2.803.0010
    803 TI Stand with stirrer and pump

    Compact titration stand with magnetic stirrer and built-in pump for solvent addition and aspiration of the titration vessel contents. Suitable for Karl Fischer titrations with Titrandos. MSB connection.
    Including comprehensive accessories, solvent bottle and waste bottle.

  • 860 KF Thermoprep
    2.860.0010
    860 KF Thermoprep

    The 860 KF Thermoprep is designed for thermal sample preparation in Karl Fischer titration.

    Numerous substances cannot be analysed by direct Karl Fischer titration as they are not soluble, react with the Karl Fischer reagent or release their water only very slowly or not until heated to high temperatures. Using tightly sealed sample vials, the sample is inserted in the oven. The samples can be subsequently analysed by any volumetric or coulometric KF titrator.

  • 885 Compact Oven Sample Changer
    2.885.0010
    885 Compact Oven Sample Changer
    The 885 Compact Oven Sample Changer is used for thermal sample preparation in Karl Fischer titration. In the oven the samples can be heated up to 250°C. The moisture contained in the sample evaporates and is transported by a dry carrier gas into the titration cell, where the analysis takes place.
  • Remote cable 885 - 899
    6.2141.390
    Remote cable 885 - 899

    Remote cable for connecting an 885 Compact Oven Sample Changer to the 899 Coulometer.

  • RS-232/USB Box
    6.2148.030
    RS-232/USB Box

    Extends the Titrino plus by two RS-232 interfaces, e.g., for the connection of balances, PC (tiBase software), LIMS. Requires 6.2151.030 cable.

  • Power Box for 899
    6.2164.500
    Power Box for 899

    The Power Box offers the option of operating the 899 Coulometer independently of the mains supply.


  • Coulometric KF equipment, including generator electrode with diaphragm
    6.5406.000
    Coulometric KF equipment, including generator electrode with diaphragm

    Complete accessory set for KF coulometer.


  • Coulometric KF equipment, including generator electrode without diaphragm
    6.5406.010
    Coulometric KF equipment, including generator electrode without diaphragm

    Complete accessory set for KF coulometer.