Just 2 clicks to moisture analysis – NIRS, a fast and accurate technique for analysis of moisture in your samples
06-06-2018 15:00 - 06-06-2018 16:00 (India)

Choice of the right method
KF titration is suitable for water content determinations in all sample forms: solids, slurries, liquids, and even gases. For low water contents between 0.001% and 1%, coulometric KF titration is recommended, whereas samples with a water content from 0.1% up to 100% are determined volumetrically.

Use KF for NIRS validation
The concordance of these two methods has to be tested now and then. For this purpose, a sample with a known amount of water is tested with KF titration as well as with NIRS and the values are compared.
NIRS XDS RapidContent Analyzer for solid samples
Spectral data acquisition
Samples in the form of powders, liquids, and creams can be analyzed with NIRS without any sample preparation. Solids are most conveniently measured in high-quality disposable glass vials, while liquids should be measured in high-quality disposable glass cuvettes. For creams, the «NIRS Slurry Cup» is recommended as it can be cleaned with only one swipe. Place the sample vessel in the instrument and start the data acquisition.

Convenient NIRS routine analysis
The use of NIRS for routine analysis is straightforward. Only two clicks are required in the software to select and start the method. The instrument automatically runs an internal wavelength standardization measurement, followed by the actual sample measurement, all in less than 60 seconds. The Vision Air 2.0 software automatically displays the result and, if required, indicates if the water content is within the user defined limits.

Webinar registration

Metrohm has shaped moisture analysis for more than half a century. Find out about new developments in water analysis and learn how near-infrared spectroscopy can increase your sample throughput and boost your productivity. You are cordially invited to join us for a FREE webinar. Here are the details:

Title: Just 2 clicks to moisture analysis – NIRS, a fast and accurate technique for analysis of moisture in your samples

Date: June 6, 2018 (Wednesday)

Time: 15:00 - 16:00 hrs (IST)

Webinar: Just 2 clicks to moisture analysis - NIRS, a fast and accurate technique for analysis of moisture in your samples

Please fill in the details for enrolling in the webinar
*
*
*
*
*
It will be a privilege to have you online in the webinar, but we would also love to hear from you, just in case the webinar time/date is not suitable to you. Connect with us or write to us at info@metrohm.in