Automated pipetting and titration system for up to 100 samples

Automated pipetting and titration system for up to 100 samples
Katalogové číslo: MATi 08

Automated system for the performance of potentiometric titrations on acids and bases. Up to 100 samples can be placed on the sample rack. The sample is pipetted out of the beaker into the external titration vessel, after which a completely automatic determination is carried out. The volume to be pipetted can vary between 0.5 and 9.0 mL. After the titration, the external vessel is cleaned thoroughly using the membrane pumps built into the Sample Processor. The control of this completely automatic analysis system takes place using the proven tiamo™ titration software.
 

  • Součástky
  • Možnosti

Kompletní rozsah dodávky a doplňkové příslušenství ke stažení

  • 786 Swing Head
    2.786.0040
    786 Swing Head
    Additional equipment for Robotic Sample Processors XL without titration or transfer heads.

    1 piece(s)

  • 800 Dosino
    2.800.0010
    800 Dosino

    Drive with write/read hardware for intelligent Dosing Units. With fixed cable (length 150 cm).

    2 piece(s)

  • 802 Stirrer (propeller stirrer) for 804 Ti Stand
    2.802.0040
    802 Stirrer (propeller stirrer) for 804 Ti Stand
    Rod stirrer with 6.1909.010 Propeller stirrer.

    1 piece(s)

  • 804 Ti Stand without stand rod
    2.804.0010
    804 Ti Stand without stand rod
    Titration stand and controller for 802 Stirrer. The 804 Ti Stand together with the optional 802 Stirrer provides an alternative to the magnetic stirrer. Without stand.

    1 piece(s)

  • 815 Robotic USB Sample Processor XL (1T/2P)
    2.815.0020
    815 Robotic USB Sample Processor XL (1T/2P)

    Robotic USB Sample Processor XL with one workstation and two built-in membrane pumps for the automatic processing of routine samples in series with large quantities and for complex sample preparation or parallel runs. Up to three dosing devices for Liquid Handling tasks can be connected.

    Because of the multitude of application variants, rack, stirrer, titration head, robotic arm, Swing Head and sample vessels must be tailored to the application and ordered separately.
     

    1 piece(s)

  • 854 iConnect
    2.854.0010
    854 iConnect

    854 iConnect - electrode cable and measuring amplifier for intelligent electrodes «iTrodes».

    1 piece(s)

  • 905 Titrando
    2.905.0010
    905 Titrando

    High-end titrator for potentiometric titration with one measuring interface for use with Dosino dosing systems.
     

    • up to four dosing systems of the 800 Dosino type
    • dynamic (DET), monotonic (MET) and endpoint titration (SET)
    • Measurement with ion-selective electrodes (MEAS CONC)
    • Dosing functions with monitoring, Liquid Handling
    • four MSB connectors for additional stirrers or dosing systems
    • "iTrode" intelligent electrodes
    • USB connector
    • For use with tiamo PC software or Touch Control unit
    • Compliance with GMP/GLP and FDA regulations such as 21 CFR Part 11, if required

    1 piece(s)

  • iEcotrode plus
    6.0280.300
    iEcotrode plus

    Intelligent, combined pH electrode with integrated memory chip for storing of sensor data. This electrode is suitable for aqueous acid/base titrations.

    The fixed ground-joint diaphragm is insensitive to contamination.
    Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.
    iTrodes can be connected to Titrando, Ti-Touch or 913/914 meters.

    1 piece(s)

  • Titration vessel lid automation
    6.1414.080
    Titration vessel lid automation

    Titration vessel lid for external use with the 6.1415.250 titration vessel base in automation.


    1 piece(s)

  • Titration vessel / 50-150 mL
    6.1415.250
    Titration vessel / 50-150 mL

    1 piece(s)

  • Sample beaker, clear glass, 75 mL, 1 piece 
    6.1432.210
    Sample beaker, clear glass, 75 mL, 1 piece 

    Sample beaker, clear glass, 75 mL, suitable for sample racks 6.2041.340, 6.2041.350, 6.2041.800 and 6.2041.900, 1 piece
     

    100 piece(s)

  • Robotic arm with transfer head for 786 Swing Head, right swinging
    6.1462.040
    Robotic arm with transfer head for 786 Swing Head, right swinging
    Transfer robotic arm for liquid handling purposes

    1 piece(s)

  • 3-way stopper with antidiffusion valve
    6.1543.210
    3-way stopper with antidiffusion valve
    Stopper with three buret tips for connecting 3 x M6 tubing

    1 piece(s)

  • Pipetting tubing / 10 mL with holder for sample processors
    6.1562.120
    Pipetting tubing / 10 mL with holder for sample processors

    Pipetting tubing for liquid transfer.

    1 piece(s)

  • Amber glass bottle / 1000 mL / GL 45
    6.1608.023
    Amber glass bottle / 1000 mL / GL 45
    For Exchange Units. Bottle for auxiliary solutions.

    2 piece(s)

  • Guide shaft to pipetting tubing
    6.1823.010
    Guide shaft to pipetting tubing
    For assembly in the transfer robotic arm on the Robotic Sample Processors

    1 piece(s)

  • Support stand for Sample Processors
    6.2001.070
    Support stand for Sample Processors
    Support stand for Sample Processors, for external titrations and dilutions (IC)

    1 piece(s)

  • Sample rack 100 x 75 mL
    6.2041.800
    Sample rack 100 x 75 mL
    Sample rack for 100 x 75 mL samples, multi-row

    1 piece(s)

  • Cable USB A – mini-DIN 8-pin
    6.2151.000
    Cable USB A – mini-DIN 8-pin
    Controller cable

    1 piece(s)

  • Buffer solution pH 4 (500 mL)
    6.2307.100
    Buffer solution pH 4 (500 mL)
    Ready-to-use buffer solution pH = 4 (25 °C), colored, with closure seal

    1 piece(s)

  • Buffer solution pH 7 (500 mL)
    6.2307.110
    Buffer solution pH 7 (500 mL)
    Ready-to-use buffer solution pH = 7 (25 °C), colored, with closure seal

    1 piece(s)

  • Buffer solution pH 9 (500 mL)
    6.2307.120
    Buffer solution pH 9 (500 mL)
    Ready-to-use buffer solution pH = 9 (25 °C), colorless, with closure seal

    1 piece(s)

  • pHit kit
    6.2325.000
    pHit kit

    Maintenance kit for pH electrodes

    The kit contains:

    • 50 mL cleaning solution
    • 50 mL 3M KCl solution
    • 50 mL storage solution
    • 2 Storage vessels
    • Instructions for use

    1 piece(s)

  • Screw nipple
    6.2730.080
    Screw nipple
    PCTFE. Used with 6.5613.000 ECO titration equipment with 722 Stirrer

    1 piece(s)

  • Wrench
    6.2739.000
    Wrench
    For tightening connectors

    1 piece(s)

  • Safety shield Transfer set to 789/815
    6.2751.120
    Safety shield Transfer set to 789/815


    Safety shield for Sample Processors with 786 Swing Head and transfer set.


    1 piece(s)

  • Dosing Unit 10 mL
    6.3032.210
    Dosing Unit 10 mL
    Dosing unit with integrated data chip with 10 mL glass cylinder and light protection, mountable on reagent bottle with ISO/DIN GL45 thread. FEP tubing connection, anti-diffusion buret tip.

    2 piece(s)

  • Tiamo 2.5 Light CD: 1 license
    6.6056.251
    Tiamo 2.5 Light CD: 1 license

    tiamo™ 2.5 Light computer program for controlling a titration system.

    • Up to two Metrohm instruments (Titrino, Titrando, etc.) can be connected; balances and other generic (i.e. non-Metrohm) instruments can be included without limitation
    • Graphical method editor with numerous templates
    • Layout manager for individual monitor interface
    • Professional database with reevaluation
    • High-performance report generator
    • Data export as PDF file, CSV, SLK
    • No parallel titration
    • No data export in XML format for LIMS
    • Dialog languages: German, English, French, Italian, Spanish, Czech, Portuguese, Polish, Russian, Slovakian, Japanese, Chinese, Traditional Chinese

     

    1 piece(s)

Kompletní rozsah dodávky a doplňkové příslušenství ke stažení

  • iAquatrode plus with Pt1000
    6.0277.300
    iAquatrode plus with Pt1000

    Intelligent, combined pH electrode with integrated memory chip for storing sensor data and with Pt1000 temperature sensor for pH measurements/titrations in ion-deficient aqueous media (e.g., drinking water, process water). This electrode shows a very short response time in these samples.

    The fixed ground-joint diaphragm is insensitive to contamination.
    When c(KCl) = 3 mol/L is used as bridge electrolyte, storage in storage solution is recommended.
    The bridge electrolyte can be easily replaced with a chloride-free electrolyte (e.g., potassium nitrate c(KNO3) = 1 mol/L (6.2310.010)). Storage in the used bridge electrolyte.
    iTrodes can be connected to Titrando, Ti-Touch, or 913/914 meters.

  • iUnitrode with Pt1000
    6.0278.300
    iUnitrode with Pt1000

    Intelligent, combined pH electrode with integrated memory chip for storing sensor data and Pt1000 temperature sensor. This electrode is particularly suitable:

    • for pH measurements and titrations in difficult, viscous, or alkaline samples
    • at elevated temperatures
    • for long-term measurements

    The fixed ground-joint diaphragm is insensitive to contamination.

    Reference electrolyte: c(KCl) = 3 mol/L, storage in storage solution.
    Alternatively: reference electrolyte for measurements at T>80°C: Idrolyte, storage in Idrolyte.
    iTrodes can be connected to Titrando, Ti-Touch or 913/914 meters.