861 Advanced Compact IC with MSM II

861 Advanced Compact IC with MSM II
Katalogové číslo: 2.861.0020
The Advanced Compact IC is suited for applications with or without suppression such as anion determinations as well as for methods combining conductivity with other types of detection.
  • Technické specifikace
  • Dokumenty
  • Součástky
Dimensions in mm (W/H/D) 259/446/355

  • Built-in six-way injection valve
  • Low-pulsation serial dual-piston pump, flow range 0.2 to 2.5 mL/min, typical 0.4 to 1.5 mL/min
  • Maximum pressure 35 MPa (350 bar, 5040 psi)
  • Pulsation absorber
  • Insulated column compartment
  • Column heating for two separation columns – adjustable between ambient temperature +5 °C and 80 °C
  • Eluent Organizer
  • Detector temperature-stabilized to better than 0.01 °C, temperature range 25...45 °C in 5-°C steps, four measuring ranges 0...50 µS/cm, 0...250 µS/cm, 0...1000 µS/cm, 0…5000 µS/cm
  • Metrohm Suppressor Module «MSM II»
  • Built-in 22-bit A/D converter
  • Analog and digital signal output
  • 8 Remote output lines for controlling external devices
  • Software for control and integration
  • Free application updates from the Internet

Kompletní rozsah dodávky a doplňkové příslušenství ke stažení

  • 
    Bottle attachment / GL 45 - 3 x UNF 10/32
    6.1602.150
    Bottle attachment / GL 45 - 3 x UNF 10/32

    For the connection of 1/16 in. capillaries. Used in conjunction with MSM auxiliary solutions and in Metrohm Inline Sample Preparation.


    2 piece(s)

  • Bottle attachment GL 45 for eluents and reagents
    6.1602.160
    Bottle attachment GL 45 for eluents and reagents

    For eluent, reagent, and rinsing bottles, with connectors for the adsorber tube and the aspiration tubing.

    1 piece(s)

  • Amber glass bottle / 1000 mL / GL 45
    6.1608.023
    Amber glass bottle / 1000 mL / GL 45
    For Exchange Units. Bottle for auxiliary solutions.

    2 piece(s)

  • Eluent bottle / 2 L / GL 45
    6.1608.070
    Eluent bottle / 2 L / GL 45

    1 piece(s)

  • Adsorbing tube, large and bent
    6.1609.000
    Adsorbing tube, large and bent
    For filling with adsorber material.

    1 piece(s)

  • PTFE capillary 0.97 mm i.d. / 5 m
    6.1803.020
    PTFE capillary 0.97 mm i.d. / 5 m
    For all IC instruments

    1 piece(s)

  • Silicone tubing 6 mm i.d., 1 m
    6.1816.020
    Silicone tubing 6 mm i.d., 1 m
    For waste tubing.

    2 piece(s)

  • PTFE aspiration tube to IC Pump, 2.5 m
    6.1834.010
    PTFE aspiration tube to IC Pump, 2.5 m
    For Compact IC, Personal IC, Basic IC, 6.5324.000 bottle holder.

    1 piece(s)

  • Clip for SGJ 14/15
    6.2023.020
    Clip for SGJ 14/15
    Clip for SGJ 14/16

    1 piece(s)

  • Column holder 8.5 mm
    6.2027.030
    Column holder 8.5 mm
    For mounting columns in column chamber of IC instruments.

    1 piece(s)

  • Column holder 11.3 mm
    6.2027.040
    Column holder 11.3 mm
    For mounting columns in column chamber of IC instruments.

    1 piece(s)

  • RS-232 cable, 5 m, DB9 – DB9
    6.2134.100
    RS-232 cable, 5 m, DB9 – DB9
    Connecting Metrohm RS-232 interface to Titrinos, 756 KF Coulometer, 762 or 771 IC Interfaces, 790 Personal IC, 743 Rancimat, 763 PVC Thermomat, 873 Biodiesel Rancimat.

    1 piece(s)

  • Tool for piston seal
    6.2617.010
    Tool for piston seal
    For removing and assembling the piston seal for all standard pump heads

    1 piece(s)

  • Pulsation absorber (metal-free)
    6.2620.150
    Pulsation absorber (metal-free)
    For all ion chromatographs

    1 piece(s)

  • Adjustable wrench
    6.2621.000
    Adjustable wrench
    Max. opening: 20 mm. For IC instruments

    1 piece(s)

  • Hexagon key 4 mm
    6.2621.030
    Hexagon key 4 mm

    1 piece(s)

  • Pressure screw 5x
    6.2744.010
    Pressure screw 5x
    With UNF 10/32 connection. For the connection of PEEK capillaries

    3 piece(s)

  • Luer/UNF coupling
    6.2744.020
    Luer/UNF coupling
    For IC instruments

    1 piece(s)

  • Coupling olive/UNF 10/32, 2x
    6.2744.034
    Coupling olive/UNF 10/32, 2x

    Connection between pressure screw and pump tubing. 2 pieces. For IC instruments with peristaltic pump.

    1 piece(s)

  • Pump tubing connector with security lock and filter
    6.2744.180
    Pump tubing connector with security lock and filter
    For the connection of a pump tubing and a capillary with built-in filter

    2 piece(s)

  • Syringe 10 mL with Luer connection
    6.2816.020
    Syringe 10 mL with Luer connection
    For various applications in IC and VA

    1 piece(s)

  • Aspiration filter
    6.2821.090
    Aspiration filter
    Pore size 20 µm, set of 5 pieces. For 6.1834.000 Aspiration tubing and 6.1821.040 and 6.1821.050 Filter tubes.

    1 piece(s)

  • Spare filter for inline filter
    6.2821.130
    Spare filter for inline filter
    Spare filter for inline filter.