Metrohm - The world's leader in ion analysis
 
nav_left
Applications nav_space Products nav_space Support nav_space Distributors nav_space About Metrohm
Support > Ion Chromatography > Instruments
Second level navigation
Select your instrument
Titration
Ion Chromatography
VA & Polarography
Stability Measuring
Meters
Successors Overview
News and Articles
Quality Management
 
Info Center
Info Request

 

 
back

788 IC Filtration Sample Processor / IC Dialysis Sample Processor

The 788 IC Filtration Processor is a powerful sample changer with a built-in ultrafiltration cell. It integrates membrane filtration as a sample preparation step directly into your automated IC system. The 788 helps to increase the working life of your separating columns while processing your critical samples fully automatically and comfortably.

Apart from ultrafiltration, the 788 IC Filtration Sample Processor can also be used for all other sample changer tasks such as direct injections or sample enrichment.

Ultrafiltration using the 788 IC Filtration Sample Processor is particularly suitable for light to medium-loaded samples such as drinking water, surface water and wastewater, digestion solutions, extracts, etc. Unloaded samples can be injected directly with the same sample changer. With strongly loaded samples, e.g. fruit juice containing fruit pulp, in-line sample dialysis with the 788 IC Dialysis Sample Processor is recommended.

The 788 IC Filtration Sample Processor/IC Dialysis Sample Processor is freely programmable and is fully supported by Metrodata IC Net. It can be used as the master or as a slave in a PC-controlled IC system. The sample rack offers places for 127 x 11 mL sample vessels. Two additional rinsing positions ensure carry-over-free sample application even with very different sample matrices.

Metrohm IC brochure

Technical information

Capacity 127 x 11 mL (standard) or 2.5 mL (optional) sample tubes plus 2 x 300 mL PE bottles (rinsing positions)
Sampling with PEEK tube (for open sample tubes) or PEEK needle (for sealed sample tubes)
Pump type 2-channel peristaltic pump
Pump tubing material PVC (Tygon®)
Ultrafiltration cell material Plexiglas (polymethylmethacrylate, PMMA)
Filter membrane material regenerated cellulose; other materials can also be used
Dialysis membrane material cellulose acetate; other materials can also be used
Pore size 0.15 µm
Diameter 47 mm
Remote control for controlling external devices
RS 232 interface for connecting a computer or printer
Dimensions in mm (W/H/D) 280/660/480

Ordering information

Order number Description
2.788.0010 788 IC Filtration Sample Processor
2.788.0020 788 IC Dialysis Sample Processor

Ordering information: Accessories and Spare Parts of the 788 IC Filtration Sample Processor

Order number Description
6.2714.010 Filter membrane, cellulose acetate; 50 pieces
6.2714.020 * Filter membrane, regenerated cellulose; 50 pieces
6.2743.040 PP sample vessels, 2.5 mL; 2000 pieces
6.2743.047 PP sample vessels, 2.5 mL; 200 pieces
6.2743.050 * PP sample tubes (11 mL); 2000 pieces
6.2743.057 PP sample tubes (11 mL); 200 pieces
6.2743.070 * PP stoppers, perforated, for sealing sample vessels; 2000 pieces
6.2743.077 PP stoppers, perforated, for sealing sample vessels; 200 pieces
6.1608.080 * PE bottle (300 mL)
6.1826.010 Pump tubing (color code white / white, i.d. = 1.0 mm) for operation without ultrafiltration
6.1826.030 * Pump tubing (color code orange / yellow, i.d. = 0.5 mm) for transferring the sample to the sample loop
6.1826.040 Pump tubing (color code black / black, i.d. = 0.76 mm) for transferring the sample
6.1826.070 * Pump tubing (color code yellow / yellow, i.d. = 1.4 mm) for transferring the sample to the ultrafiltration cell
  * Already included in the standard equipment of the Sample Processor

Ordering information: Accessories and Spare Parts of 788 IC Dialysis Sample Processor

Order number Description
6.2714.010 * Filter membrane, cellulose acetate; 50 pieces
6.2714.020 Filter membrane, regenerated cellulose; 50 pieces
6.2743.040 PP sample vessels, 2.5 mL; 2000 pieces
6.2743.047 PP sample vessels, 2.5 mL; 200 pieces
6.2743.050 * PP sample tubes (11 mL); 2000 pieces
6.2743.057 PP sample tubes (11 mL); 200 pieces
6.2743.070 * PP stoppers, perforated, for sealing sample vessels; 2000 pieces
6.2743.077 PP stoppers, perforated, for sealing sample vessels; 200 pieces
6.1608.080 * PE bottle (300 mL)
6.1826.010 Pump tubing (color code white / white, i.d. = 1.0 mm) for operation without ultrafiltration
6.1826.030 * Pump tubing (color code orange / yellow, i.d. = 0.5 mm) for transferring the sample to the sample loop
6.1826.040 * Pump tubing (color code black / black, i.d. = 0.76 mm) for transferring the sample
6.1826.070 Pump tubing (color code yellow / yellow, i.d. = 1.4 mm) for transferring the sample to the ultrafiltration cell
  * Already included in the standard equipment of the Sample Processor
 
   
788 IC Filtration Sample Processor / IC Dialysis Sample Processor
borderline
Analytical instruments in Swiss quality