The following overview shows you details of the important
features and will help you choose the optimum Titrino.
|
|
|
|
|
|
|
|

808 Titrando |
809
Titrando |
842
Titrando |

835 Titrando |
836
Titrando |
841
Titrando |

857 Titrando |
|
|
|
|
|
|
|
| Dosing elements |
1 integrated Dosimat with
806 Exchange Unit |
Space for two 800 Dosinos
with 807 Dosing Unit |
1 integrated Dosimat with
806 Exchange Unit |
Space for two 800 Dosinos
with 807 Dosing Unit |
Space for
two 800 Dosinos with 807 Dosing Unit |
Space for
two 800 Dosinos with 807 Dosing Unit |
| Attachment of additional dosing elements |
9 x 805 Dosimat with 806 Exchange Unit |
12 x 800 Dosino with 807
Dosing Unit |
9 x 805 Dosimat with 806 Exchange Unit |
12 x 800 Dosino with 807 Dosing Unit |
12 x 800 Dosino with
807 Dosing Unit |
12 x 800 Dosino with
807 Dosing Unit |
| Intelligent Exchange Unit/Dosing
Unit with integral Data Chip |
yes |
yes |
yes |
yes |
yes |
yes |
yes |
| Dosing steps per cylinder
volume (resolution) |
808 Titrando and 805
Dosimat: 20'000 |
800 Dosino:
10'000 |
835 Titrando and 805
Dosimat: 20'000 |
800 Dosino: 10'000 |
800
Dosino: 10'000 |
800
Dosino: 10'000 |
| Operation, dialog |
Touch Control,
PC Control or tiamo™ |
| Determination
Modes |
|
|
|
|
|
|
|
| DET: Dynamic
Equivalence-point Titration |
yes
|
yes |
- |
yes
|
yes
|
- |
yes |
| MET: Monotonic
Equivalence-point Titration |
yes
|
yes
|
- |
yes
|
yes
|
- |
yes |
| SET: titration
to a preset endpoints with automatic conditionings |
yes
|
yes
|
yes
|
yes
|
yes
|
yes |
yes |
| KFT: Karl Fischer
Titrations |
- |
- |
- |
yes |
yes
|
yes |
yes
(2.857.0020) |
| STAT: pH/mV stat
titration |
- |
- |
yes
|
yes
|
yes
|
- |
yes |
| DOS: Controlled dosing with
monitoring of pH value and temperature |
- |
- |
yes |
yes |
yes |
- |
yes |
| MEAS: pH/mV/temp.
measurement |
Resolution:
0.001 pH, 0.1 mV, 0.1 °C; measuring interval:
100 ms |
| MEAS CONC: Direct measurement
using ISE and calculation of concentration |
yes |
yes |
- |
yes |
yes |
- |
yes
(2.857.0020) |
| CAL: Calibration
with automatic buffer recognition |
yes
|
yes
|
yes
|
yes |
yes |
yes |
yes |
| Liquid handling with expanded
dosing instructions for the 800 Dosino |
yes |
yes |
yes
|
yes |
yes |
yes
|
yes |
| Automatic reagent
exchange |
yes |
yes |
yes
|
yes
|
yes |
yes |
yes |
| Tandem dosing:
uninterrupted dosing or titrating with two burets |
only dosing |
only dosing |
yes |
yes |
yes |
only
dosing |
yes |
|
|
|
|
|
|
|
|
808
Titrando |
809
Titrando |
842
Titrando |
835
Titrando |
836
Titrando |
841
Titrando |
857
Titrando |
|
|
|
|
|
|
|
| Hardware |
|
|
|
|
|
|
|
| Second, galvanically separated
measuring interface for pH, U/mV, T/°C |
Option
|
yes (2.857.0020) |
| Connection of 854 iConnect
and intelligent electrodes «iTrodes» |
- |
- |
- |
- |
- |
-
|
yes
|
| Ipol
& Upol: integrated programmable polarizer |
yes
|
yes
|
|
yes
|
yes
|
|
yes
(2.857.0020) |
| Differential amplifier |
Option
|
| Temperature sensor |
Pt 1000
or NTC |
| Real-time curve display |
yes:
on Touch Control (90 x 120 mm color graphics LSC)
or PC screen |
| Dialog languages |
English
and German; additional languages can easily be added |
| Stirrers, titration stand |
4 x 801
Magnetic Stirrer or 4 x 802 Rod Stirrer with 804 Titration
Stand
or 803 KF Titration Stand |
| Attachment of Dosimats, Dosinos, stirrers |
4 MSB
connectors (Metrohm Serial Bus, Daisy Chain) |
| Stirrer on/off and setting of stirrer
speed via Titrando |
yes |
| Sample changer connection |
1 sample
changer via USB |
| Attachment of balances, printer, PC, PC
keyboard, barcode reader and/or LabLink |
Via 2
USB Slave Ports, RS 232 Box USB (option) |
| Bluetooth USB Adpater for wireless communication
with printer, balance… |
Option
(for 840 Touch Control) |
| Sequence can be freely programmed by the
user |
yes |
| Additional possibilities of titration-curve
evalution |
fixed endpoints,
pK values (HNP), minimum/maximum, break point (photometry
or conductometry) |
| PCMCIA memory-card port |
yes (for
methods, results, Keycard (user identification), backup) |
| 8 MB CompactFlash Card with large number
of user methods |
yes |
| Data memory |
Method
and sample data, results (database) |
| Comprehensive GLP/GMP functions |
yes |
| meet compliance requirements of |
FDA
21 CFR Part 11 |
| Access control |
by
means of login with password protection, «Electronic
Signature» |
| Check for result limits |
yes |
|
|
|
|
|
|
|
|
808
Titrando |
809
Titrando |
842
Titrando |
835
Titrando |
836
Titrando |
841
Titrando |
857
Titrando |
|
|
|
|
|
|
|