Metrohm - The world's leader in ion analysis
 
nav_left
Applications nav_space Products nav_space Support nav_space Distributors nav_space About Metrohm
  
Titration
Potentiometric Titr.
Karl Fischer Titration
Automation
Thermometric Titr.
Dosing & Stirring
Ion Chromatography
VA / Polarography / CVS
Stability Measuring
ProcessLab
Meters
Sensors
Accessories
 
Sales Documents
Technical Documents
Info Request

 

786 Swing Head

More Samples in Minimal Space

If a 786 Swing Head is used then the numbers and amounts of samples can be varied within very wide limits. The increased flexibility results as the range of positions on the Sample Processor which can be accessed is considerably increased. The 786 Swing Heads are true masters in accuracy: they move pipetting tips to microtiter plates millimeter by millimeter or take up disposable filters.

Titration version

Direct titration in the sample vessel with everything you need. The titration head is large enough to accommodate an 802 Rod Stirrer, two sensors as well as three buret tips. At the end of the titration this inserts is rinsed by three spray nozzles and the rinsing solution is aspirated off completely. This reliably prevents cross-contamination.

Pipetting version

Pipetting is a complicated sample preparation step - but fortunately it can be fully automated. You no longer need to bother about the time-consuming measuring out of the sample and also profit from the high degree of dosing accuracy of the Dosino, which works with a volume resolution of 10 000 steps per buret volume.

External titration

The Sample Processor cannot only use its versatile components on the sample rack, it is also able to serve externally situated titration cells. Pipetting and/or transferring is no problem for the Sample Processor. The samples are transferred to the external cell where the determination takes place, e.g. in a connected titration cell. During the determination the Sample Processor is ready to carry out other tasks, no matter whether these include a parallel titration or the preparation of the next sample.

No time is lost, as time is money!

Ordering Information

786 Swing Head

2.786.0010 786 Swing Head with Transfer Head Left
2.786.0020 786 Swing Head with Transfer Head Right
2.786.0030 786 Swing Head with Titration Head
2.786.0040 786 Swing Head - special model (without Titration Head)

Ordering information for 786 Swing Head accessories


DIS-COVER
6.1462.080 Transfer Swing Head «DIS-COVER» (left)
   
6.2037.050 Cover Lid for sample beaker 75 mL
6.2037.060 Cover Lid for sample beaker 200 mL

Titration version including beaker sensor
6.1462.150 Titration head for 786 including sensor (left/right)
6.1462.160 Titration head for 786 including sensor (left/max)
6.1462.170 Titration head for 786 including sensor (right/max)

Automation in Titration – quite easy with Metrohm

Get more information

If you wish to get more information you may either submit our reply form or send an e-mail to info@metrohm.com.

 
   
786 Swing Head
borderline
Analytical instruments in Swiss quality