831 KF Coulometer
Determination of water content down to trace amounts
|
|
The 831 KF Coulometer has established
itself for the determination of very small amounts of
water. Besides its extremely compact design, the it fulfills
every Karl Fischer analysis task. The clear display provides
information about the relevant
titration parameters and gives an unmistakable presentation
of the course of titration in form of a curve showing µg
water against time. Improved coulometric generator cells
and reagents ensure interruption-free, reliable results
over a long period.
This favorably-priced coulometer version does not habe a built-in printer, but
otherwise corresponds exactly to the specifications of
the 756 KF Coulometer. |
The innovative solution: convincing arguments
- no titer determination is required in coulometry
- titration cells with or without diaphragm - it's
your choice!
- Metrodata VESUV Light, a PC program for backup and
database functions is included in the delivery package
- two RS 232C interfaces for communication with balance,
computer and external printer
- compatible with the 774 Oven Sample Procesor
- on-line control of reagent consumption versus time
- dialogue languages: English, French, German, Italian,
Portugese, Spanish, Swedish
- meets the requirements of ISO 900X and GLP
- ideal building block for titration networks with
the FDA 21 CFR Part 11 compliant PC program TiNet 2.5
- programmable service and validation intervals
- programmable upper limits for contents and reagent
consumption during automated analysis
|
Just push the button |
Connecting a 700
Dosino to the 831 KF Coulometer allows to siphon
off the contents of the coulometric cell and fill it
with fresh reagent. As the KF vessel remains closed,
no humidity can enter the system. Within a minimum of
time the analysis cell is conditioned again. |
Very flexible but easy to use |
Extensive flexibility and user-friendliness are no contradiction
in terms any more. The 831 KF Coulometer has two principle
working modes: The expert mode allows it to use all different
features of this high tech device. In the standard mode
just a few keystrokes are enough to start your analysis.
|
| The 831 KF Coulometer stores up to 100 different
methods in its internal memory. Methods can easily be transferred
and reloaded via the RS 232C interface to a PC. |
If there is moisture in it, Metrohm titrators will
find it
|
Get more information
If you wish to get more information on the 831 KF
Coulometer you may either submit our reply
form or send an e-mail to info@metrohm.com.
|
Ordering information |
| 2.831.0010 |
831 KF Coulometer including titration cell with
diaphragm, 728 Magnetic Stirrer, Metrodata VESUV Light and extensive
accessories |
| 2.831.0110 |
831 KF Coulometer including titration cell without
diaphragm, Metrodata VESUV Light and extensive accessories (without
728 Magnetic Stirrer) |
|
|
Options
|
| 6.5613.000 |
ECO semi-micro titration equipment |
| 6.0234.100 |
Combined "Long Life" micro pH electrode for eco
semi-micro titration equipment |
| 6.0338.100 |
Double Pt electrode with plug-in head, for eco Karl Fischer
titrations |
| 6.2104.020 |
Electrode cable with F plug, length 1 m |
| 6.2104.030 |
Electrode cable with F plug, length 2 m |
[an error occurred while processing this directive]
Stirrer, titration stands
|
| 2.703.0010 |
703 Titration Stand
Highly integrated, manually operated titration stand with stirrer and pump
for addition of solvents and aspiration of spent solution when performing
endpoint titrations (SET) with conditioning between determinations; especially
suitable for Karl Fischer titrations with the eco semi-micro titration equipment |
| 6.1439.010 |
Tube for addition or siphoning with the 703 Titration
Stand (cell without diaphragm) |
| 6.1805.200 |
Additional PTFE tubing with two M8 screw nipples
for 703 Titration Stand |
| |
or |
2.728.0040
|
728 Magnetic Stirrer with stand, electrode holder and stirring bar |
2.727.0010
|
727 Titration Stand with rinsing pump and rinsing head;
requires 2.722.0010 |
| 2.722.0010 |
722 Rod Stirrer for 2.727.0010, with controller and stirrer propeller |
| 2.727.0100 |
727 Titration Stand with controller and built-in magnetic stirrer, rinsing
pump and rinsing head |
Dosino and Dosing Unit for liquid handling (cell without diaphragm)
|
| 2.700.0020 |
700 Dosino
Buret drive with fixed connecting cable (mini DIN connector), to be mounted
directly, together with the Dosing Unit, on reagent bottles with GL45 thread.
Aspirates spent titrant and adds fresh reagent from the Coulometer's
cell. |
| 6.5617.000 |
Equipment for aspirating the cell contents, including
50 mL Dosing Unit and 6.2055.100 support for two bottles. |
Additional dispensing units
|
2.776.0010
|
776 Dosimat as auxiliary Dosimat |
| 2.765.0010 |
765 Dosimat as auxiliary Dosimat |
| 6.2139.000 |
Connecting cable Titrino - 776 or 765 Dosimat |
Remote Box
|
6.2148.000
|
Remote Box for connecting PC keyboard and barcode reader |
774 Oven Sample Processor
|
2.774.0010
|
Highly flexible instrument combining sample changer, oven and gas pump.
Accommodates 35 sample vessels ("20 mm Headspace Vials") and one
conditioning vessel. Programming and manual operation via keypad equipped
with a two-line LCD display. Extensive accessories including, e.g., crimping
tool, 1000 sample vials and 1000 septum covers. Includes tiamo™
Software. |
Metrodata VESUV© 3.0
|
| 6.6008.200 |
Metrodata VESUV 3.0, including Hardware Dongle, for n instruments |
| PC program (Windows 95, 98, NT, 2000
or XP) for the acquisition of titration data via an RS 232C interface, method
backup, printing of reports, curve display and reprocessing of data. Data
base with filter, search and query functions, data export to Excel, Lotus,
LIMS
Dialog in English or German. |
[an error occurred while processing this directive]
Connecting cables for printers, balances and PCs
|
| 6.2134.110 |
Connecting cable for Custom DP 40 printer |
| 6.2134.050 |
Connecting cable for Epson printers FX, LX, LQ |
| 6.2134.060 |
Cable for Sartorius balances MP8 and MC1 |
| 6.2134.040 |
Cable for PC mit 9-poligem Stecker (DB9) |
| 6.2125.110 |
Cable for PC with 9-pin connector (DB 9) |
Cables
|
| 6.2141.010 |
Cable Coulometer 768 KF Drying Oven |
| 6.2134.040 |
Remote control cable Coulometer (RS-232-C Interface) PC |
|
|
|
 |
|
|
|
|
|