Volumetric
KF Titrators |
Coulometric
KF Titrators |
| Tech Specs
|
870
KF Titrino plus |
795
KFP Titrino |
841
Titrando |
756
KF Coulometer |
831
KF
Coulometer |
| Recommended measuring range |
100 ppm
... 100% |
100 ppm
... 100% |
100
ppm ... 100% |
10 µg ...
200 mg |
10 µg ...
200 mg |
| Requires volumetric titer determination |
yes |
yes |
yes |
- |
- |
Absolute method,
no titer determination necessary |
- |
- |
- |
yes |
yes |
| Titration to preset pH/mV endpoints |
- |
- |
yes |
- |
- |
| pH calibration and pH measurement |
- |
- |
yes |
- |
- |
| Real-time volume/time curve on graphics LCD |
yes |
yes |
yes |
yes |
yes |
| Input of maintenance and validation intervals |
- |
yes |
yes |
yes |
yes |
| Dialog languagues |
1 |
7 |
4 |
7 |
7 |
| Integrated printer |
- |
- |
- |
yes |
- |
| Predefined Methods |
yes |
yes |
yes |
yes |
yes |
| MEMORY CARD External memory card |
- |
- |
yes |
- |
- |
| Comprehensive memory for sample data, methods and results |
- |
yes |
yes |
yes |
yes |
| Result memory |
- |
yes |
yes |
yes |
yes |
| Version for Coulometer cell with or without diaphragm |
- |
- |
- |
yes |
yes |
| Parallel titration |
- |
- |
yes (tiamo) |
- |
- |
| Connections,
Interfaces |
|
|
|
|
|
| Connection for PC keyboard and/or barcode reader (option) |
yes |
yes |
yes |
yes |
yes |
| Second galvanically separated measuring interface |
- |
- |
option |
- |
- |
| Automatic change of reagent with Dosino (option) |
- |
- |
yes |
yes |
yes |
| Connection for further dosing devices for auxiliary
solutions (Titrando: 800, Titrino: 776, 765) - back-titration |
- |
2 |
4 |
- |
- |
| Connection for two additional dosing devices for titrations
(800) |
- |
- |
4 |
- |
- |
Connection for KF Oven
for automatic water extraction |
yes |
yes |
yes |
yes |
yes |
| Connection for stirrer |
yes |
yes(1)
|
yes
(1) |
yes(1) |
yes(1) |
| Connection for sample changer |
- |
yes |
yes |
yes |
yes |
| Interface for printer, PC, balance |
yes
USB |
yes
RS 232C |
yes
USB |
yes
RS 232C |
yes
RS 232C |
| Additional interface |
optional
RS 232C |
yes
RS 232C |
yes
USB |
yes
RS 232C |
yes
RS 232C |
| Software |
|
|
|
|
|
| tiamoTM
software for PC titration network |
- |
yes |
yes |
yes |
yes |
| PC Control or Touch Control |
- |
- |
yes |
- |
- |
| TiNet 2 software for PC titration network |
- |
yes |
- |
yes |
yes |
| Compatible with VESUV 3.0 software for databases |
- |
yes |
- |
yes |
yes |
| VESUV 3.0 software included in the scope of delivery |
- |
yes |
- |
- |
- |
| |
|
|
|
|
|
| (1) The stirrer connections of 841 Titrando,
795 KFT Titrino and of 756 and 831 KF Coulometer are remote
controlled by the titrator. |
| Take your time and make your choice. If
you wish to get more information on KF Titrinos or KF
Coulometers you may either submit our reply
form or send an e-mail to info@metrohm.com.
|