Karl Fischer Titrators: Product Overview

 

Volumetric
KF Titrators

Coulometric
KF Titrators

Tech Specs
870 KF Titrino plus 795 KFP Titrino 841 Titrando 756 KF Coulometer 831 KF
Coulometer
Recommended measuring range 100 ppm ... 100% 100 ppm ... 100% 100 ppm ... 100% 10 µg ...
200 mg
10 µg ...
200 mg
Requires volumetric titer determination
yes
yes
yes
-
-
Absolute method,
no titer determination necessary
-
-
-
yes
yes
Titration to preset pH/mV endpoints
-
-
yes
-
-
pH calibration and pH measurement
-
-
yes
-
-
Real-time volume/time curve on graphics LCD
yes
yes
yes
yes
yes
Input of maintenance and validation intervals
-
yes
yes
yes
yes
Dialog languagues
1
7
4
7
7
Integrated printer
-
-
-
yes
-
Predefined Methods
yes
yes
yes
yes
yes
MEMORY CARD External memory card
-
-
yes
-
-
Comprehensive memory for sample data, methods and results
-
yes
yes
yes
yes
Result memory
-
yes
yes
yes
yes
Version for Coulometer cell with or without diaphragm
-
-
-
yes
yes
Parallel titration
-
-
yes (tiamo)
-
-

Connections, Interfaces

 
Connection for PC keyboard and/or barcode reader (option)
yes
yes
yes
yes
yes
Second galvanically separated measuring interface
-
-
option
-
-
Automatic change of reagent with Dosino (option)
-
-
yes
yes
yes
Connection for further dosing devices for auxiliary solutions (Titrando: 800, Titrino: 776, 765) - back-titration
-
2
4
-
-
Connection for two additional dosing devices for titrations (800)
-
-
4
-
-
Connection for KF Oven
for automatic water extraction
yes
yes
yes
yes
yes
Connection for stirrer
yes
yes(1)
yes (1)
yes(1)
yes(1)
Connection for sample changer
-
yes
yes
yes
yes
Interface for printer, PC, balance
yes
USB
yes
RS 232C
yes
USB
yes
RS 232C
yes
RS 232C
Additional interface
optional
RS 232C
yes
RS 232C
yes
USB
yes
RS 232C
yes
RS 232C

Software

 
tiamoTM software for PC titration network
-
yes
yes
yes
yes
PC Control or Touch Control - - yes - -
TiNet 2 software for PC titration network
-
yes
-
yes
yes
Compatible with VESUV 3.0 software for databases
-
yes
-
yes
yes
VESUV 3.0 software included in the scope of delivery - yes - - -
           
(1) The stirrer connections of 841 Titrando, 795 KFT Titrino and of 756 and 831 KF Coulometer are remote controlled by the titrator.
Take your time and make your choice. If you wish to get more information on KF Titrinos or KF Coulometers you may either submit our reply form or send an e-mail to info@metrohm.com.
 
   
Analytical instruments in Swiss quality