Metrohm - The world's leader in ion analysis
 
nav_left
Applications nav_space Products nav_space Support nav_space Distributors nav_space About Metrohm
Products > Potentiometric Titration > Photometer
  
Titration
Potentiometric Titration
Karl Fischer Titration
Automation
Thermometric Titr.
Dosing & Stirring
Ion Chromatography
VA / Polarography / CVS
Stability Measuring
ProcessLab
Meters
Sensors
Accessories
 
Sales Documents
Technical Documents
Info Request

 

662 Photometer

Insert the photometer into the sample, not vice versa!

The 662 Photometer allows exact measurement of absorption and transmission as well as their direct conversion to concentration values. The analog output is used in combination with a titrator for the photometric endpoint determination.

A moderately priced, practice-oriented alternative in photometry.

  • Display of transmission, absorption and concentration: Transmission and absorption are the traditional measured quantities. Additionally, the 662 Photometer determines the concentration of sample solutions after previous calibration.
  • Glass fiber light guide: Measurements can be performed in any sample container, be it a beaker, a test tube, a titrating vessel, etc. The long, flexible light guide is just as convenient to use as a pH electrode; its resistance to solvents is excellent.
  • Gradual filter: Thanks to the continuous wavelength scale with stepless adjustment, measurements can always be performed at the point of maximum absorption. Accordingly, there is no loss of sensitivity due to non-optimal selection of the wavelength.
Expensive cells are no longer needed: the long, flexible glass-fibre light guide of the 662 Photometer makes photometric determinations just as easy as, for example, a pH measurement – in a wide range of different vessels and over the entire visible wavelength range (400 ... 700 nm).

If you wish to get more information you may either submit our reply form or send an e-mail to info@metrohm.com.

Ordering Information, Options

2.662.0010

662 Photometer (CE)

Spectral range lambda = 400...700 nm with continuously variable filter; for direct measurements of ab-sorption, transmission, concentration as well as for titrations; automated calibration with standards; with analog output; incl. 6.1108.010 light guide with 3.616.2390 mirror with 2 x 10 = 20 mm light path, support rod and holder.


Options

6.1250.000 Mirror with 2x 5 = 10 mm light path, to be attached onto probe
6.2116.000 Cable for Titrinos
3.540.2290 RS 232C data output
On request Connecting cable for 662 Photometer data output
 
   
Photometer with flexible light guide