tiamoTM 2.3 - New features
New instruments
089 Photometer
New or updated commands
- MET Cond: Command for monotonic equivalence point titrations with conductometric measurement.
- MEAS TMF: Command for the determination of the transmission factor of a measurement configuration
- MEAS Opt: Command for extinction measurements (new for the 089 Photometer).
- MEAS Opt Conc: Command for concentration measurements (direct measurement) with spectrometer or photometer.
- CAL LOOP Opt: Loop command for the calibration of colorimetric sensors, used together with the command CAL MEAS Opt.
- CAL MEAS Opt: Command for measuring standard solutions for the calibration of colorimetric sensors, used together with the command CAL LOOP Opt.
- ELT LOOP: Loop command for the electrode test (test of pH electrodes), used together with the command ELT MEAS.
- ELT MEAS: Command for measuring calibration buffers for the electrode test (test of pH electrodes), used together with the command ELT LOOP.
New features in the program part Database
- The determination comment is available as an additional column in the determination overview; it is also possible to search for it and to generate a filter for this purpose.
New features in the program part Method
- There are method templates available for MET Ipol, MET Cond, STDADD auto, CAL Cond and ELT LOOP.
- Drift-controlled measurements are now possible with the Avantes spectrometer.
- In the case of commands with conditioning, it is possible to control the sample addition time manually ("infinite" sample addition time).
- The command MEAS Opt has a tab Additional measured values.
New features in the program part Configuration
- New subwindow Colorimetric sensors. They are used in the commands CAL MEAS Opt and MEAS Opt Conc.
- In the configuration of the sample changers, a position can be defined on the tab Initializing position which is automatically moved to when initializing the sample changer.
- One can define electrode type templates for the electrode test, of which three are supplied in the default settings (Gel, Non-aqueous, Standard).
tiamoTM 2.2 - New features
New Instruments:
859 Titrotherm
New commands:
- TET: Command for thermometric titration with the 859 Titro
- RLS DEV: Release device for parallel working on another workplace
- RLS DOS: Release dosing device for parallel working on another workplace
New features & improvements in the program part Method
- In the formula editor the sample data variables of the next sample line are available.
New features & improvements in the program part Workplace
- Sample data: By typing in the first characters to the field Method the selection of the method is continuously restricted and allows fast selecting of the method required
- Statistical results are being additionally regressed against the Sample size. This results in the new variables .SLO, .ITC, .COR. This can be used e.g. for validation purposes, for titer and blank value determinations (thermal titration).
New features & improvements in the program part Configuration
- Besides client-specific common variables, there are also global variables available which are saved over all clients and can be used in formulas under the designation 'GV.Name'.
- New sensor type: Thermoprobe for Titrotherm.
tiamoTM 2.1 - New features
New Instruments:
Titrando 851
Titrando 852
New commands:
- BRC: Command for coulometric titration for determining the bromine consumption (bromine index/bromine number)
New features & improvements in the program part Method
- Automatic start of the titration after adding sample for KFC
- Formula editor: Function Student t
tiamoTM 2.0 - New features
New Instruments:
856 Conductivity Module
867 pH Module
864 Balance Sample Processor
Avantes Spectrometer
874 KF Oven Sample Processor
90X Titrando Family
New commands:
- MEAS TC Cond: Command for the Measurement of the temperature coefficients of the conductivity.
- MEAS Ref: Command for the Measurement of a reference spectrum (Avantes Spectrometer).
- MEAS Spec: Command for the Measurement of the sample spectrum (Avantes Spectrometer).
- MEAS Opt: Command for absorbance measurements (Avantes Spectrometer).
- CAL Cond: Command for Conductivity standards measurements for the determination of the cell constants of conductivity sensors.
- CAL Spec: Command for wavelength calibration (Avantes Spectrometer).
New features & improvements in the program part Workplace
- An ongoing command can be interrupted from the live display.
- The application notice of a method can be displayed while editing the sample table.
- The number of sample identifications has been increased from 8 to 16.
- Calculated and external measured values can be displayed as a live measured value.
New features & improvements in the program part Database
- Determinations can be searched for and filtered in accordance with serial numbers (of instruments, dosing units).
- Determinations can be sent per E-mail directly from the database.
- A second y axis can be displayed in the Curve evaluation while reprocessing.
- PDF reports now contain extractable text, e.g. for further editing with LIMS.
New features & improvements in the program part Method
- The measuring point list can be exported automatically as a CSV file.
- The formula editor contains a molar mass calculator.
- Methods can be sent directly via E-mail from the method administration.
- The Round arithmetic function of the formula editor now uses commercial rounding instead of bankers rounding.
- A method now contains its own entire history when it is exported and imported.
- Up to 9 fixed endpoints can be evaluated. The measured quantity which is evaluated can be selected separately for each fixed endpoint.
New features & improvements in the program part Configuration
- The user administration can be configured in such a way that only methods which are signed at Level 2 can be carried out.
- Export and archive files of the audit trail now contain a checksum. The new Verify export/archive function in the Audit Trail sector can be used to check whether these files were modified afterwards.
New features & improvements in the program part Manual Control
- Manual operation is now an autonomous program part that is accessible at all times through the vertical toolbar on the left-hand edge of the program.
- Measurements are now possible in manual operation.
tiamoTM 1.3 - New features
Instruments:
tiamo™ 1.3 supports the new member of the titrator family Titrando. It now includes the 888 and 890 Titrando.
tiamoTM 1.2 - New features
Instruments:
tiamo™ 1.2 supports the new member of the titrator family Titrando. It now includes the 857 Titrando and the 854 iConnect with the new generation of intelligent electrodes – the iTrodes.
New commands:
Gran evaluation:
tiamo™ now also supports the Gran evalution of potentiometric titrations with one single jump done with the Titrando.
Raw data in determination database:
The raw data report of each determination is shown in a separate tab in the database view.
Sample addition time for commands with conditioning:
The waiting time between the stop of conditioning and start of titration during which the sample can be added can now be edited.
tiamoTM 1.1 - New features
New instruments:
842 Titrando for carrying out STAT titrations
855 Robotic Titrosampler – the complete package for automating your application
New commands:
STAT Mode:
tiamoTM 1.1 now has a STAT mode for titrating to a preset control point and then keeping the measured value constant. This combines a cleverly devised control technique with highly developed evaluation algorithms. And another piece of good news for existing 835/836 Titrando users: in combination with tiamoTM 1.1 your instruments are extended by the STAT mode free of charge.
Monitored Dosing, e.g. for use in synthesis labs
Tandem Dosing:
In tandem operation dosing now takes place interruption-free. This means that both rapid reactions and those with high reagent consumption can now be followed.
Standard Addition:
It is not only possible to carry out direct measurement with ion-selective electrodes; standard addition is now also available.
Ready-to-use methods make your titration work easier
In addition to templates for standard methods, tiamoTM 1.1 includes a wide range of examples of methods with detailed application notes which provide you with accurate information needed for carrying out the titration in an optimal manner.
Problem-free work in compliance with GMP/GLP and FDA regulations such as 21 CFR Part 11
- To complete your documentation it is now possible to print out both the User Administration and Security Settings.
- In addition, live modifications such as changing the stirring speed during the titration are now documented in the database under Messages.
- As requested by many customers, the input time and data source are now saved together with the sample weight. “Total traceability” with tiamoTM 1.1.
Client-Server system – even clearer and more mature
tiamoTM 1.1 multi is now more tolerant toward network interruptions and variations.
You retain the overall view – in the Program Administration Window you can see which clients are currently active at any time.