663 VA Stand for Autolab potentiostats

2.663.0020 663 VA Stand for Autolab potentiostats
Workstation for Autolab potentiostats. Complete accessory with all electrodes for a complete measurement system: Multi Mode Electrode (MME), Ag/AgCl reference electrode, and glassy carbon (GC) auxiliary electrode. Option: Rotating Disk Electrode (RDE). Without cable and power supply. Connection to Autolab potentiostats with IME663 interface.
 
2.663.0020 663 VA Stand for Autolab potentiostats
Option: Rotating Disk Electrode (RDE). Without cable and power supply. Connection to Autolab potentiostats with IME663 interface.
2.663.0020 663 VA Stand for Autolab potentiostats
Weight 10.986
2.663.0020 663 VA Stand for Autolab potentiostats
Parts
6.2816.020 Syringe 10 mL with Luer connection
6.2709.030 Stopper for pipetting opening
6.1226.050 Mercury drop capillary (silanized) for MME
6.2816.030 Needle with Luer connection
6.2723.230 Dust cover for 647/663/694
6.1415.210 Titration vessel / 10-90 mL
6.1245.010 Electrolyte vessel
6.1801.080 Tubing for nitrogen connection
6.2709.050 Stopper for stirrer opening on VA Stand
6.2703.000 Stand ring for titration vessels
6.2301.100 Pb Ion standard 1 g/L 50 mL
6.1241.020 Electrode Holder
6.2711.030 Tray for filling the MME
6.0728.020 Ag/AgCl Reference Electrode
6.1246.120 Multi-Mode Electrode pro
6.1244.020 Driving belt
6.1247.000 Glassy Carbon Rod (GC)
6.1204.200 Stirrer for VA Stand
6.1247.020 Needles for MME
6.2308.020 Electrolyte 3 mol/L KCl (250 mL)
6.2406.000 Mercury drop catcher
Options
6.1418.220 Titration vessel with thermostat jacket / 20-90 mL
6.5327.010 MVA-As, equipment for arsenic determination
6.1415.150 Titration vessel / 5-70 mL
6.1204.210 Driving axle for rotating disk electrode (RDE) with titanium axle, thread M3
6.1204.190 Platinum electrode tip 1 mm for CVS, shaft made of glass
6.2709.040 Stopper for MME opening on VA Stand
6.1415.250 Titration vessel / 50-150 mL
6.0343.000 Separate Pt Rod Electrode
MVA-UV MVA-UV: supplementary equipment for UV digestion
6.0728.010 Ag/AgCl Reference Electrode
6.1204.140 Gold Electrode Tip
6.1204.220 Driving axle for rotating disk electrode (RDE) with titanium axle and mercury contact, thread M3
6.1204.160 Platinum Electrode Tip for CVS 2 mm
6.5327.000 MVA-Hg, equipment for mercury determination
6.1418.150 Titration vessel with thermostat jacket / 5-70 mL
6.1456.210 Measuring vessel / 10-90 mL
6.1418.250 Titration vessel with thermostat jacket / 50-150 mL
6.1204.180 Ultra-Trace electrode tip
6.1204.600

Glassy Carbon Electrode Tip, shaft made of glass.

6.2802.000 Polishing set for solid-state electrodes
6.1415.220 Titration vessel / 20-90 mL
6.1204.110 Glassy Carbon Electrode Tip
6.1204.610 Platinum electrode tip 2 mm for CVS, shaft made of glass
6.1204.130 Silver Electrode Tip
6.1204.170 Platinum Electrode Tip for CVS 3 mm
6.1204.150 Lateral Gold Electrode Tip
2.663.0020 663 VA Stand for Autolab potentiostats
AB-136 Polarographic determination of styrene in polystyrene and copolymers
AB-70

Polarographic determination of nitrate in water samples, soil and plant extracts, vegetable juices, meat and sausages, fertilizers, liquid manure, etc.

AB-131 Voltammetric determination of aluminum
AB-231

Voltammetric determination of zinc, cadmium, lead, copper, thallium, nickel, and cobalt in water samples according to DIN 38406 Part 16

AB-132 Polarographic determination of molybdenum in strongly ferruginous materials
AB-050 Determination of lead in petroleum products by stripping voltammetry
AB-176 Simultaneous determination of lead and tin by anodic stripping voltammetry
AB-179 Polarographic determination of maleic and fumaric acid alone or in mixtures
AB-126 Polarographic determination of quinine
AB-127 Polarographic determination of ammonium and nitrite
AB-266 Determination of titanium and uranium by voltammetry
AB-097 Voltammetric determination of tocopherols (vitamin E) in edible oils and fats
AB-224

Polarographic determination of pyridoxine (vitamin B6)

AB-098 Determination of ascorbic acid (vitamin C) and its compounds
AB-226 Determination of arsenic by stripping voltammetry at the rotating gold electrode
AB-096 Determination of mercury at the rotating gold electrode by anodic stripping voltammetry
AB-220 Determination of ultratrace amounts of platinum by stripping voltammetry
AB-057 Polarographic determination of nicotine
AB-060 Polarographic determination of fructose
AB-215 Polarographic determination of folic acid (vitamin B9, vitamin Bc)
AB-113

Determination of lead, cadmium, and copper in foodstuffs, wastewater, and sewage sludge by anodic stripping voltammetry after digestion

AB-251 Polarographic determination of cinchocaine (dibucaine) in pharmaceutical preparations
AB-110 Polarographic determination of free cyanide
AB-213 Polarographic determination of nicotinamide
AB-250 Polarographic determination of diazepam in body fluids and pharmaceutical preparations
AB-219 Polarographic determination of riboflavin (vitamin B2)
AB-254

Determination of zinc, cadmium, lead, and copper by anodic stripping voltammetry using carbon electrodes

AB-218 Polarographic determination of thiamine (vitamin B1)
AB-116 Polarographic/voltammetric determination of chromium in small quantities
AB-117 Determination of selenium by stripping voltammetry
AB-114

Polarographic determination of five metals (copper, cobalt, nickel, zinc, and iron) in a single run

AB-199 Polarographic determination of sulfide and sulfite
AB-196 Polarographic determination of formaldehyde
AB-241

Determination of cadmium and lead at the «Ultra Trace» graphite electrode by anodic stripping voltammetry

AB-317 Voltammetric determination of iron
AB-243

Determination of chromium at the «Ultra Trace» graphite electrode by cathodic stripping voltammetry

AB-147 Simultaneous trace determination of seven metals in «electronic grade» materials using stripping voltammetry
AB-207 Stripping voltammetric determination of silver
AB-242

Determination of tungsten at the «Ultra Trace» graphite electrode by anodic stripping voltammetry

AB-076 Polarographic determination of nitrilotriacetic acid (NTA) and ethylenediaminetetraacetic acid (EDTA) according to DIN 38413 part 5
AB-192 Determination of thiourea in the lower ppm and ppb range by polarography and stripping voltammetry
AB-146 Direct polarographic determination of trace amounts of molybdenum in water
AB-074

Polarographic and stripping voltammetric analysis methods for thallium, antimony, bismuth, and iron (copper, vanadium)

AB-191 Simultaneous polarographic determination of cystine and cysteine
AB-073

Polarographic analysis – half-wave potentials of organic substances

AB-190 Polarographic determination of 4-carboxybenzaldehyde in terephthalic acid
AB-141 Analysis of edible fats and oils
AB-186 Determination of aluminum in water samples by adsorptive voltammetry
AB-036

Polarographic analysis – half-wave potentials of inorganic substances

AB-037 Determination of chromium in iron and steel
2.663.0020 663 VA Stand for Autolab potentiostats
8.663.1003 Instructions for Use 663 VA Stand, english
8.663.3003 Declaration of conformity for 663 VA Stand (English)