Home
Products
Applications
Service
Support
Company
Contact

852 Titrando with generator electrode with diaphragm and Touch Control

2.852.0060 852 Titrando with generator electrode with diaphragm and Touch Control

Coulometer including generator electrode with diaphragm, Touch Control, 801 Stirrer and complete volumetric titration cell.

The coulometric Karl Fischer Titration is the method of choice for low level water determinations (10 μg … 10 mg absolute water content) in liquid, solid and gaseous samples. As it is an absolute method a titer determination is not necessary.

Recommended measuring range coulometry: 10 µg...200 mg absolute water

With the 852 Titrando coulometric as well as volumetric Karl Fischer titrations are carried out straightforwardly and quickly.


  • Coulometric and volumetric titration
  • Bromine index
  • Automatic titration start
  • Automatic reagent exchange
 
2.852.0060 852 Titrando with generator electrode with diaphragm and Touch Control

Coulometric and volumetric titrations

If the water content is too high for coulometric Karl Fischer titration, the 852 Titrando can handle this without any problem. With this instrument you have the possibility of analyzing samples with water contents ranging from only a few micrograms up to 100%.

Bromine index

As a new feature the 852 Titrando offers the possibility of determining the bromine index coulometrically. The conventional titration cell as well as the generator electrode with diaphragm can also be used for this application. Only the anolyte and the catholyte need to be changed.

Automatic titration start

It can happen very quickly that the sample is injected into the titration cell without first pressing the start button. In this case the water of the sample is conditioned away and the determination has to be repeated. With the 852 Titrando this wont happen to you ever again. The instrument recognizes the addition of sample and starts the determination automatically. In this way you save not only reagents but also sample and, above all, precious time.

Dosino and Dosing unit

Up to four Dosinos and Dosing units can be attached to the MSB-ports of the Coulometer. In combination with the 852 Titrando these can be used for volumetric Karl Fischer titrations as well as addition of the sample, water standard or auxiliary solutions like solubilizers.
Furthermore the reagent exchange can be automated, which means that the titration cell does not need to be opened and therefore no moisture can enter the cell. Long conditioning times after a reagent exchange can thus be avoided.

2.852.0060 852 Titrando with generator electrode with diaphragm and Touch Control
Weight 7.115
2.852.0060 852 Titrando with generator electrode with diaphragm and Touch Control
Parts
6.0338.100 Double Pt-wire electrode for volumetry

6.0341.100 Double Pt wire electrode for coulometry

6.0344.100 Generator electrode with diaphragm

6.1244.040 Set of seals
6.1403.030 KF adsorber tube for coulometer cell
6.1403.040 KF Adsorber tube
6.1414.030 KF titration vessel lid
6.1415.220 Titration vessel / 20-90 mL
6.1415.250 Titration vessel / 50-150 mL
6.1437.000 SGJ stopper SGJ 14
6.1446.060 Stopper / B-14/15 / M10
6.1448.010 Septum 12 mm, 5 pieces
6.1448.020 Septum 16 mm, 5 pieces
6.1464.320 KF titration vessel / 80-250 mL / coulometric
6.1903.020 Stirring bar / 16 mm
6.1903.030 Stirring bar / 25 mm
6.2001.090 Base plate on both sides
6.2013.010 Clamping ring
6.2016.030 Support rod / 250 mm
6.2043.005 Holding clip for bottles
6.2047.020 Titration vessel holder
6.2103.130 Adapter red 2 mm plug / 4 mm socket
6.2103.140 Adapter black 2 mm plug / B socket 4 mm
6.2104.020 Electrode cable / 1 m / F
6.2104.120 Electrode cable / 1 m / H
6.2412.000 Weighing boats

6.2701.040 GL 18 screw cap with hole

6.2713.000 Sleeve
6.2713.010 Sleeve
6.2713.020 Sleeve
6.2730.010 Screw nipple
6.2730.020 Septum stopper
6.2730.030 Stopper
6.2738.000 Funnel
6.2811.000 Molecular sieve
6.2816.030 Needle with Luer connector
6.2816.090 Syringe 5 mL
6.6064.010 USB Memory Stick for 900 Touch Control 
Options
2.136.0100

Polytron PT 1300 D

2.800.0010

800 Dosino

2.803.0010

803 TI Stand with stirrer and pump

2.860.0010

860 KF Thermoprep

2.874.0010

874 USB Oven Sample Processor

2.874.0020

874 USB Oven Sample Processor customized

6.2148.010 Remote Box MSB
6.2148.020 RS-232/USB box
6.3032.120 Dosing Unit 2 mL
6.3032.150 Dosing Unit 5 mL
6.3032.210 Dosing Unit 10 mL
6.3032.220 Dosing Unit 20 mL
6.3032.250 Dosing Unit 50 mL
6.5406.000

Coulometric KF equipment, including generator electrode with diaphragm

6.5406.010

Coulometric KF equipment, including generator electrode without diaphragm

6.5617.000

Equipment for reagent replacement

2.852.0060 852 Titrando with generator electrode with diaphragm and Touch Control
MI-2011-2-AP-1

Application report: Metrohm – tailored analysis for the bio fuel industry

2.852.0060 852 Titrando with generator electrode with diaphragm and Touch Control
8.851.5001 Brochure: 851 Titrando / 852 Titrando
8.852.8003

Manual for 852 Titrando