| MATi 12 | Automated COD determination |
Automated system for the potentiometric determination of COD samples in series of up to 21 samples. The titration is carried out directly inside the reaction vessel on the rack. Afterwards the electrode equipment is automatically cleaned using the internal membrane pumps and the reaction tube is emptied. The system is controlled by the titration software tiamo™. Consists of: 1 x 814 USB Sample Processor 1 x 905 Titrando 1 x 854 iConnect 5 x 800 Dosino 1 x 741 Stirrer | |
|
| MATi 11 | Automated volumetric KF titration including sample preparation |
Fully automated system for volumetric Karl Fischer water determination in up to 53 samples. The system is controlled by tiamo™ and consists of an 815 USB Sample Processor XL, an 901 Titrando and numerous accessories. The samples are weighed out into beakers, sealed to protect them against atmospheric moisture and placed on the rack. Prior to titration a known amount of KF reagent is added and the sample crushed using a Polytron. In a second step the water content is titrated. With the Polytron the samples are comminuted into small pieces and the contained water is released. This method is also suitable for the analysis of hardly soluble samples (e.g. tablets). In many cases solubility promoters can thus be avoided. The system consists of: 1 x 815 USB Sample Processor XL 1 x 901 Titrando 1 x Polytron 1 x 772 Pump Unit 2 x 800 Dosino 2 x 786 Swing Head 6.9903.048 Double Pt wire electrode 6.9914.139 Titration head 6.9914.140 Robotic arm 6.9920.141 Sample rack | |
|

| MATi 13 |
MATi 13 Fully automated determination of the permanganate index
|
|
Automated system for determination of the permanganate index, according to DIN EN ISO 8467. Up to 24 samples can be placed on the rack and processed in a series. The sample is pipetted from the sample beaker to the external titration vessel and fully automatically analyzed according to the DIN standard. After titration, the external titration vessel is thoroughly cleaned by the sample changer's built-in membrane pumps . The system is controlled by
tiamo ™, the titration software.
The system consists of:
1 x 814 USB Sample Processor
1 x 907 Titrando
1 x 801 Magnetic stirrer
1 x 786 Swing Head
3 x 800 Dosino
6.9915.078 Holder to transfer tubing 25 mL
6.9915.079 Transfer tubing 25 mL with 2 x M8 to 6.9915.078
The thermostat for heating of the external titration vessel must be ordered separately.
| |
|
| MATi 10 | Automated volumetric KF titrations |
Fully automated system for volumetric Karl Fischer water determination in up to 24 samples. The system is controlled by tiamo™ and consists of an 814 USB Sample Processor, an 901 Titrando and numerous accessories. The samples are weighed out into beakers, sealed to protect them against atmospheric moisture and placed on the rack. Prior to titration the samples are dissolved in a known amount of KF working medium and the water content is then titrated in a second step. This method is particularly suitable for samples that dissolve quickly in the KF working medium. The solubility can also be improved by using a suitable solubility promoter. The system consists of: 1 x 814 USB Sample Processor 1 x 901 Titrando 2 x 800 Dosino 1 x 741 Stirrer | |
|
| MATi 08 | Automated pipetting and titrating system for up to 100 samples |
Automated system for potentiometric titrations of acids and bases. Up to 100 samples can be placed on the sample rack. The sample is pipetted from the sample beaker to the external titration vessel and is analyzed fully automatically. The amount of sample to be pipetted can be chosen freely in the range from 0.5 to 9.0 mL. After the titration the external vessel is cleaned thoroughly by means of the membrane pumps of the Sample Processor. The system is controlled by the tiamo™ titration software. The system consists of: 1 x 815 Robotic USB Sample Processor XL 1 x 786 Swing Head 1 x 905 Titrando 1 x 854 iConnect 2 x 800 Dosino 1 x 802 Stirrer 1 x 804 Ti Stand | |
|
| MATi 07 | Automated titration system for up to 28 samples |
Fully automated system for the determination of potentiometric titrations like acid/base/redox and halide titrations in series of up to 28 samples. The system is controlled by the tiamo™ titration software. After the determination the titration equipment is cleaned and the beaker is emptied automatically. The system consists of: 1 x 815 Robotic USB Sample Processor XL 1 x 786 Swing Head 1 x 905 Titrando 1 x 854 iConnect 1 x 800 Dosino 1 x 802 Stirrer The electrode must be chosen separately according to the selected application. | |
|
| MATi 06 | Automated titration of acids and bases for up to 12 samples |
Fully automated system for the potentiometric titration of acids and bases in series of up to 12 samples. The titration is carried out directly inside the beaker on the rack. Afterwards the electrode is cleaned automatically and the beakers are emptied using the membrane pumps of the Sample Processor. The system is controlled by the user-friendly tiamo™ titration software. The system consists of: 1 x 814 USB Sample Processor 1 x 905 Titrando 1 x 854 iConnect 1 x 800 Dosino 1 x 802 Stirrer | |
|
| MATi 04 | Automated coulometric KF titrations |
MATi 4 is a fully automated system for coulometric KF titrations with high sample throughput. The sample rack of the Sample Processor accommodates up to 160 samples in 6-mL-vials. The samples are transferred to an external coulometric cell where KF titration is carried out. The system is controlled by the tiamo™ titration software. The system consists of: 1 x 815 Robotic USB Sample Processor XL 1 x 786 Swing Head 1 x 851 Titrando 1 x 800 Dosino 1 x 801 Stirrer | |
|
| MATi 03 | Non-aqueous titrations |
Direct non-aqueous titration of pharmaceutical ingredients and other samples in series of up to 59 samples. The system is characterized by its special resistance against solvents. It is controlled by the tiamo™ titration software. The system consists of: 1 x 815 Robotic USB Sample Processor XL 1 x 786 Swing Head 1 x 905 Titrando 1 x 854 iConnect 2 x 800 Dosino 1 x 843 Pump Station 1 x 802 Stirrer | |
|
| MATi 02 | Automated TAN/TBN Analysis |
Computer-controlled and fully automated titration system for direct potentiometric determination of TAN and TBN values in petroleum products in series of up to 59 samples. The analysis follows the ASTM norms D664 and D2896. The system is characterized by the excellent resistance against the solvents used for this application. Data is collected and the system controlled by the tiamo™ titration software. The system consists of: 1 x 815 Robotic USB Sample Processor XL 1 x 786 Swing Head 1 x 905 Titrando 1 x 854 iConnect 2 x 800 Dosino 1 x 843 Pump Station 1 x 802 Stirrer | |
|
| MATi 01 | Fully automated water analysis |
|
Fully automated, PC-controlled system for water analysis, equipped with a dosing device enabling the quick and precise transfer of 100 mL water samples. After the conductivity measurement, the pH value, alkalinity as well as Ca and Mg content are determined in an external cell. A maximum of 59 samples can be placed on the rack. The system is controlled by the proven
tiamo
™ titration software.
The system consists of:
1 x 815 Robotic USB Sample Processor XL
2 x 786 Swing Head
1 x 905 Titrando
1 x 854 iConnect
3 x 800 Dosino
1 x 856 Conductivity Module
1 x 802 Stirrer
1 x 804 Ti Stand
6.9958.007 Swing arm with 100 mL overflow buret
| |
|