Unitrode with Pt 1000  (without cable - electrode head U)

Choose according to your needs:

Easy-to-use 827 pH lab with alternatively Primatrode or Unitrode electrode for routine analysis or high-precision 780 pH meter with a wide range of capacities.

 
6.0258.600 Unitrode with Pt 1000  (without cable - electrode head U)

High performance in difficult samples and at high temperatures.


  • High temperature resistance (0...100 °C)
  • Very low alkali error
  • Short stabilisation times after temperature changes
  • Can be used for long-term measurements
  • Fixed ground-joint diaphragm insensitive to contamination
  • Detachable cable
 
6.0258.600 Unitrode with Pt 1000  (without cable - electrode head U)

Advantages of the new electrode-head:

  • Price advantage: Lower price for new electrode than for an electrode with fixed cable
  • Easy storage: The electrode can easily be stored between measuring series. There is no cable in the way, because this can be stored separately or remain on the instrument.
  • Fast electrode exchange / Easy mounting also in automated systems: The cable remains fixed in the titration system, only the sensor needs to be exchanged on the titration head.
  • Metrohms contribution to environment protection: Reduction of cable waste
    The unique multi-contact connector for laboratory electrodes gives a high signal quality due to its gold-plated contacts.
     
6.0258.600 Unitrode with Pt 1000  (without cable - electrode head U)
Indicator electrode type Glass electrode
Bridge electrolyte type c(KCl) = 3 mol/L
Diaphragm Fixed ground-joint diaphragm
Shaft diameter top (mm) 12
Resistance (kOhm) 3
Measuring range 0...14
Temperature range, short-term (°C) 0...100
Temperature sensor Pt1000
Reference electrolyte type c(KCl) = 3 mol/L
SGJ sleeve flexible SGJ sleeve
Membrane glass type U
Membrane resistance 150...500
Temperature range, long-term (°C) 0...100
Electrolyte flow rate (μl/h) 3...30
Plug for filling opening Orifice
Electrode slope > 0.97
Electrode zero point (mV) 0 ± mV (pH = 7)
Shaft diameter bottom (mm) 12
Min. immersion depth (mm) 25
Internal reference electrode type LL system
Electrode plug-in head Plug-in head type
Indicator electrode shape Cylinder
Weight 0.178
6.0258.600 Unitrode with Pt 1000  (without cable - electrode head U)
Parts
1 pcs6.1236.050Sleeve with SGJ 14/12 mm
1 pcs6.2008.040 Storage vessel  
Options
6.2104.600 Electrode cable for plug in head U/plug F, 2x2 mm B, 1m
6.2104.610 Electrode cable for plug in head U/plug F, 2x2 mm B, 2m
6.2308.020 Electrolyte 3 mol/L KCl (250 mL)
6.2308.040 Idrolyte (250 mL)
6.2323.000 Storage solution
6.2325.000 pHit kit
6.0258.600 Unitrode with Pt 1000  (without cable - electrode head U)
6.0258.600 Unitrode with Pt 1000  (without cable - electrode head U)
8.108.1176 Leaflet
8.109.5001

Brochure: 6.0258.600 Unitrode with plug-in head U

8.109.8044

Leaflet for pH glass electrodes