"ProfIC 7 – Anion" – Professional IC System with Inline Dilution and Dialysis
|
ProfIC Systems are predefined combinations of Professional IC instruments, Sample Processors and peripheral instruments covering different applications. Software, columns and racks are selected according to the respective application.
How to identify the right ProfIC system? | | |
ProfIC 7 - Anion "ProfIC 7 – Anion" – Professional IC System with Inline Dilution and Dialysis
|
|
The professional IC system with conductivity detection enables the fully automatic determination of anions that are present in very high concentrations and in a problematic matrix. Emulsions, samples containing fats and proteins or heavily contaminated waste waters are not always compatible with ion chromatography, even after upstream filtration. That is why "ProfIC 7" is equipped with the Metrohm-patented Inline Dialysis (European Patent 0 820 804, US Patent 5,861,097). Schematic diagram
|
ProfIC 7 - Anion "ProfIC 7 – Anion" – Professional IC System with Inline Dilution and Dialysis
|
|
Thus it is possible to determine anions, even in cutting oil emulsions, milk products or bodily fluids such as blood and urine.
"ProfIC 7" offers in addition the option of automatic inline dilution of the sample. This takes place at an external position on the 858 Professional Sample Processor. Working together with a transfer tubing, the 800 Dosino performs the Liquid Handling in a highly precise manner.
The intelligent MagIC Net™ software controls both the dialysis and also the dilution steps. MagIC Net™ carries out all the calculations, so that only the dilution factor needs to be entered. In addition, the software offers the option of intelligent dilution, i.e. the dilution takes place automatically, depending on the highest concentration of the calibration. The software monitors the results and makes logical decisions.
The anion system is equipped with sequential suppression. Very high sensitivity is achieved with the unique combination of chemical and downstream CO
2 suppression. This makes it possible to combine the flexibility of the carbonate/hydrogen carbonate eluents with the low background conductivity of a hydroxide eluent.
The 858 Professional Sample Processor with pump takes care of the sample transfer. Numerous sample racks are available for volumes in the range of 0.5 - 500 mL.
|
|
Parts
1 x 2.800.0010 800 Dosino
1 x 2.801.0010 801 Stirrer (magnetic stirrer)
1 x 2.850.2110 850 Professional IC
1 x 2.850.9010 850 Conductivity Detector
1 x 2.858.0020 858 Professional Sample Processor
1 x 6.3032.210 dosing unit 10 mL
1 x 6.5330.000 IC equipment for dialysis
1 x 6.5330.020 IC equipment for sample dilution
IC column, sample rack, sample vessels as well as MagIC Net™ have to be ordered separately, depending on the particular application.
|
ProfIC 7 - Anion "ProfIC 7 – Anion" – Professional IC System with Inline Dilution and Dialysis
|
| Weight |
null |
ProfIC 7 - Anion "ProfIC 7 – Anion" – Professional IC System with Inline Dilution and Dialysis
|
| Parts |
|
|
| Options |
|
|
ProfIC 7 - Anion "ProfIC 7 – Anion" – Professional IC System with Inline Dilution and Dialysis
|
ProfIC 7 - Anion "ProfIC 7 – Anion" – Professional IC System with Inline Dilution and Dialysis
|
|
8.850.5007 |
Brochure: Intelligent Ion Chromatography - 850 Professional IC, 872 Extension Module, 858 Professional Sample Processor |
|
|
 |
|
References
|
|

Phytos laboratory for pharmaceutical analysis, a leading supplier of comprehensive solutions for the pharmaceutical industry, has benefited from the reliability of Metrohm products for many years.
|
|
 |