Straightforward multi-point calibration using a single standard (english)

ProfIC Systems are predefined combinations of Professional IC instruments, Sample Processors and peripheral instruments covering different applications. Software, columns and racks are selected according to the respective application.

How to identify the right ProfIC system? 

 
8.000.6042EN Straightforward multi-point calibration using a single standard (english)
The combination of 850 Professional IC, 858 Professional Sample Processor, Dosino and MagIC NetTM software offers a variety of automated ion chromatographic sample preparation and calibration techniques available as an anion, cation or dual channel system. Calibration is straightforward and requires only one multi-ion standard.Inline calibration allows the calibration of any standard concentration in the ppt range by using one single stable standard solution at the ppb level. By using a preconcentration column and switching the valves one, two or more times different calibration concentrations at the ultra-trace level can be created with unprecedented reproducibility. The inline preconcentration technique uses a pre-concentration column and is ideally suited for trace analysis in complex matrices, especially when combined with matrix elimination. Besides facilitating the preparation of g/L to ng/L calibration graphs Metrohm`s intelligent techniques are capable of logical decision making. While Metrohm`s intelligent Partial Loop technique (MiPT) allows samples with a wide concentration range to be injected without previous manual dilution, the intelligent inline dilution technique, after the first sample injection, compares peak areas, calculates, if necessary, the dilution factor, dilutes and automatically re-injects the sample. The presented inline techniques allow the rationalization of the time-consuming, error-prone and cost-intensive manual preparation of standard solutions. They guarantee that the determined sample concentrations always lie within the calibration range. Higher sample throughputs as well as lower analysis costs and improved data reliability are achieved.
 
Download EN
8.000.6042EN Straightforward multi-point calibration using a single standard (english)
null
null
8.000.6042EN Straightforward multi-point calibration using a single standard (english)
Weight 0.0
8.000.6042EN Straightforward multi-point calibration using a single standard (english)
8.000.6042EN Straightforward multi-point calibration using a single standard (english)
8.000.6042EN Straightforward multi-point calibration using a single standard (english)