Home
Products
Applications
Service
Support
Company
Contact
 

 

IC Amperometric Detector

Scheme-Conductometric-Detection

 
To learn more about IC detection principles «Conductivity», «Amperometry» and «UV/VIS» please watch animations. 
Click here.

 
2.850.9110 IC Amperometric Detector

Compact and intelligent amperometric detector for intelligent IC instruments. Outstanding selectivity due to the four measuring modes: DC, PAD, flexIPAD and CV, as well as the excellent signal/noise ratio and the very fast stabilization of the measuring signal guarantee the highest in measurement precision.


 
2.850.9110 IC Amperometric Detector

The iDetector

The IC Amperometric Detector measures even the smallest of changes in current or charge, depending on the selected measuring mode. Measuring cells in wall-jet or thin-layer geometry are available for different applications.

  • Amperometric detector for the determination of electroactive substances
  • Flexible setup as stand-alone detector or detector block for IC and HPLC Outstanding selectivity due to a wide range of measuring modes: DC, PAD, flexIPAD, CV
  • High sensitivity through excellent signal/noise ratio
  • Large measuring range for demanding applications
  • Easy to use due to intelligent and robust measuring cells with wall-jet or thin-layer geometry
  • Large variety of working electrodes: Au, Ag, Pt, GC
  • Various maintenance-free reference electrodes
  • Measurement of current or charge without a specific range
  • Very fast start-up without long conditioning times
  • Leak sensor in the cell compartment
  • Fully compliant with Metrohm inline sample preparation techniques such as
  • Inline Dilution, Inline Ultrafiltration or Inline Dialysis
  • Controlled by MagIC Net™ – the software for ion chromatography
null
2.850.9110 IC Amperometric Detector
Weight 2.469
2.850.9110 IC Amperometric Detector
Parts
6.1831.010 PEEK capillary 0.25 mm i.d. / 3 m
6.2165.000 Connecting cable to 61257XXX
6.2744.014 Pressure screw 2x
6.2813.040 Dummy cell to the IC Amperometric Detector.
Options
6.1257.010 Wall-Jet Cell
6.1257.100 Thin-Layer cell
6.1257.210 Au working electrode, 3 mm
6.1257.220 GC working electrode
6.1257.230 Pt working electrode
6.1257.240 Ag working electrode
6.1257.260 Au working electrode, 2 mm
6.1257.720 Ag/AgCl reference electrode for 6.1257.xxx
6.1257.740 Pd reference electrode to 6.1257.xxx
6.1257.810 Spacer 50 µm to Wall-Jet Cell
6.1257.820 50 µm spacer to Thin-Layer cell
6.1257.830 Spacer 25 µm to Wall-Jet Cell
6.1257.840 25 µm spacer to Thin-Layer cell
6.2802.200 Maintenance set for 6.1257.2XX working electrodes
6.2802.210 Polishing disks for 6.2802.200 maintenance set
6.5333.000 IQ/OQ Kit for IC
6.5337.000 IC equipment Wall-Jet cell: without electrodes
6.5337.010 IC equipment Wall-Jet cell: Carb (Au, Pd)
6.5337.020 IC equipment Wall-Jet cell: Cyanide (Ag, Pd)
6.5337.030 IC equipment Wall-Jet cell: Anion (GC, Ag/AgCl).
6.5337.200 IC equipment Thin-Layer cell: without electrodes
2.850.9110 IC Amperometric Detector
AN-P-045

Sugars in breakfast cereals – sample preparation applying the 815 Robotic Soliprep for LC

AN-P-046

Lactose in lactose-free dairy products applying pulsed amperometric detection after Inline Dialysis

2.850.9110 IC Amperometric Detector
8.850.5007

Brochure: Intelligent Ion Chromatography - 850 Professional IC, 872 Extension Module, 858 Professional Sample Processor

8.850.8062

Manual for IC Amperometric Detector, 2.850.9110

8.896.5000

Brochure: 896 Professional Detector / 850 IC Amperometric Detector - Amperometric detection for determining electroactive components