iTrodes - intelligent electrodes
|
 |
|
The iTrodes of the new intelligent electrode generation allow the storage of such important sensor data as
- article and serial numbers,
- calibration data,
- calibration history,
- working life and
- calibration validity period.
All sensor data is read in automatically when the iTrode is connected to the Titrando.
|
Mix-ups or editing errors are therefore eliminated. The electrode is identified automatically. If the type of electrode is not the same as that defined in the method the user is informed. This means that it is not possible to use the wrong electrode.
Monitoring functions allow the exclusion of electrodes whose calibration data lies outside the limits or whose calibration period has expired. The calibration data stored in the chip makes the electrode transferable; it does not need to be recalibrated each time that it is used with a different instrument.
For connection to your intelligent Titrator/Meter please use 854 iConnect.
| | |
| 6.0471.300 | iPt Titrode |
For redox titrations without change of pH value, with memory chip for sensor data such as article and serial number, calibration data and calibration history. | |
| | 6.0470.300 | iAg Titrode |
For precipitation titrations without change of pH value, with memory chip for sensor data such as article and serial number, calibration data and calibration history. | |
| | 6.0451.300 | Combined iPt-ring electrode |
Intelligent sensor for redox titrations with change of pH value and ORP measurement. | |
| | 6.0450.300 | Combined iAg-ring electrode |
For precipitation titrations of halides, sulfides, hydrogen sulfide, mercaptans and cyanides with change of pH value. | |
| | 6.0280.300 | iEcotrode Plus |
Excellent durability in routine work at a fair price. | |
| | 6.0279.300 | iSolvotrode |
|
Combined pH glass electrode for titrations in nonaqueous media, with memory chip for sensor data such as article and serial number, calibration data and calibration history.
| |
| | 6.0278.300 | iUnitrode with Pt 1000 |
Combined pH glass electrode for measurements in difficult media, with memory chip for sensor data such as article and serial number, calibration data and calibration history. | |
| | 6.0277.300 | iAquatrode Plus with Pt 1000 |
Combined pH glass electrode for measurements in poorly conducting media, with memory chip for sensor data such as article and serial number, calibration data and calibration history. | |
| | 2.854.0010 | 854 iConnect |
854 iConnect - electrode cable and measuring amplifier for intelligent electrodes «iTrodes». | |
|
|
|
 |
|
FAQs
|
|