Optrode
|
Optical sensors for titrations with photometric endpoint recognition. | | |
6.1115.000 Optrode
|
|
Sensor for titration with photometric endpoint recognition.
- Eight wavelengths: 470, 502, 520, 574, 590, 610, 640 and 660 nm
- 100% solvent-resistant through glass shaft
- Compact and space-saving
- Very simple cleaning
- Simple change of wavelengths
Both new and existing titration systems can be furnished with the Optrode. The power supply is provided directly through the USB interface of a Metrohm instrument (Titrino plus, Ti-Touch, Titrando, USB sample changer). With older models without a USB interface, the power supply can also be provided by means of an optional USB power supply unit.
|
6.1115.000 Optrode
|
|
Application examples:
- Photometric titrations in accordance with USP and EP (nonaqueous)
- Determination of the carboxyl end groups (nonaqueous)
- TAN/TBN in accordance with ASTM D974 (nonaqueous)
- Chloride in silicone products (nonaqueous)
- Sulfate determination
- Fe, Al, Ca in cement
- Water hardness (total hardness and Ca/Mg)
- Chondroitin sulfate in accordance with USP
|
|
Shaft length: 135 mm
Shaft diameter: 12 mm
Minimum immersion depth: 30 mm
Shaft material: Glass
Plug-in head: Fixed cable
Temperature range: 0 - 40°C
|
6.1115.000 Optrode
|
| Height (housing) (mm) |
177 |
| Shaft material |
Glass |
| Temperature (housing) (°C) |
0 ... 40 |
| Shaft diameter top (mm) |
12 |
| Shaft diameter bottom (mm) |
12 |
| Min. immersion depth (mm) |
30 |
| SGJ sleeve |
Flexible SGJ sleeve |
| Electrode plug-in head |
Fixed cable (l = 1 m) with plug F |
| Weight |
0.264 |
6.1115.000 Optrode
|
| Parts |
|
|
| Options |
|
|
6.1115.000 Optrode
|
|
AN-T-077 |
Photometric determination of sulfate in aqueous solutions
|
|
AN-T-078 |
Determination of aluminum in cement using photometric titration
|
|
AN-T-079 |
Determination of calcium in cement by photometric titration of the solubilized product according to EN 196-2
|
|
AN-T-080 |
Determination of iron in cement using photometric titration
|
|
AN-T-081 |
Determination of magnesium in cement using photometric titration
|
|
AN-T-082 |
Determination of nickel using photometric titration
|
|
AN-T-083 |
Photometric titration of chondroitin sulfate according to Ph. Eur. and USP
|
|
AN-T-084 |
Fully automatic determination of the total, calcium and magnesium hardness of water samples using photometric titration
|
|
AN-T-085 |
Photometric determination of sulfate
|
|
AN-T-086 |
Photometric determination of ascorbic acid (Vitamin C)
|
|
AN-T-087 |
Photometric determination of carboxyl end groups in polymers
|
|
AN-T-088 |
Photometric EDTA titration of bismuth nitrate according to Ph. Eur. and USP
|
|
AN-T-089 |
Photometric EDTA titration of manganese sulfate according to Ph. Eur. and USP |
|
AN-T-090 |
Photometric EDTA titration of zinc sulfate according to Ph. Eur. and USP |
|
AN-T-091 |
Fully automatic determination of total content of Ba, Ca, Mg, Pb and Zn in unused lubricating oils
|
|
AN-T-092 |
Fully automatic photometric titration of the total acid number (TAN) according to ASTM D974-11 |
|
MI-2013-1-AP-2 |
Application report: Photometric titrations with the Optrode
|
6.1115.000 Optrode
|
|
8.109.5015 |
Brochure: Optrode – Titration in a new light
|
|
8.109.8038 |
Manual Optrode
|
|
AN-T-093 |
Fully automatic photometric determination of the total base number (TBN)
|
|
|
 |
|
FAQs
|
|
Answered by our product specialists.
|
|
 |